Frontier Energy System and Power Engineering, FESPE, is an International Journal registered at e-ISSN: 2720-9598. FESPE is officially published by Electrical Engineering, State University of Malang, Indonesia. This journal is the Peer Review and Open Access International Journal, published twice a year in January and July relating to the broad scope of the Energy System and Power Engineering. FESPE provides a flagship forum for academics, researchers, industry professionals, engineers, consultants, managers, educators, and policymakers who work in engineering to contribute and disseminate new innovative works in energy systems, power engineering, and other related themes.
Articles 55 Documents
Buck Converter Output Voltage Control System Using Proportional Integral Differential Method on Solar Cell Battery Charging Dyah Lestari; Anik Nur Handayani; Nurike Mey Dwijayanti
Frontier Energy System and Power Engineering Vol 4, No 2 (2022): JULY
Publisher : Universitas Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17977/um049v4i2p35-41

Abstract

Although fossil fuels are still readily available, their use is becoming less and less common. Solar energy produced by panels on the roof can be used as a source of power. Semiconductor-based solar panel technology can absorb photons from sunshine and transform them into ecologically beneficial electrical energy. Of course, a control device that regulates the electrical energy charging system is required when using solar cells as a power source to charge a battery. This device is typically referred to as a charge controller. The DC-DC converter of the buck type with a Ziegler Nichols-based Proportional Integral Differential (PID) control approach utilizing Arduino Uno is the control system utilized in this solar cell battery charging. The buck converter reduces and stabilizes the solar panel's output voltage following the requirements for charging the accumulator. For charging batteries, a set point voltage of 13.8 V is employed. By testing the converter with both static and dynamic loads, the research that has been done can produce results. The 35 Watt lamp static load test results with a fixed voltage source show that the set point voltage is 13 V and that it takes 28 s to attain a steady condition. When applied to dynamic loading using a battery charge of 12 V/7.5 Ah with a 20 WP solar panel source during hot, partly cloudy weather, the charging efficiency is 68 percent. A steady state of about 28 s may be claimed to be a satisfactory control system response.
Potential Electrical Saving and Efficiency in Lighting and Cooling Systems in Car Dealership Building Deni Sri Indarto; Mochammad Facta; Karnoto Karnoto; Hermawan Hermawan
Frontier Energy System and Power Engineering Vol 4, No 1 (2022): JANUARY
Publisher : Universitas Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17977/um049v4i1p01-11

Abstract

An energy audit is an activity to determine the pattern of energy consumption and consumption in order to identify various potential energy savings that are feasible and can be carried out in a fair manner without compromising comfort and health. The location of the work is the building of the car dealership. The several works are carried out to measure, calculate and analyse data to get Energy Consumption Intensity or ECI of the building. In the next step of the research, preliminary calculations and analyse are used to look for technical improvement steps to increase the low Energy Consumption Intensity value in certain rooms. The technical improvement steps are then reviewed to obtain the necessary recommendations to achieve a specific efficiency score. The electricity efficiency audited according to the standard is 2,698.65 kWh/ month. High-purity hydrocarbon refrigerant is suggested to use directly to replace synthetic refrigerants in chillers. This refrigerant has various advantages including 20% energy saving, no ozone causing damage and greenhouse gas effects. Lighting software is used to simulate the number of light points. The advantage of this software is that it not only focuses on the engineering side, but also in terms of visualization. By using Lighting software we can simulate a room with lamps that are actually available in the worldwide lighting industry.
Stability Simulation of 150 kV Malang Power Grid Arif NA; Goro Fujita
Frontier Energy System and Power Engineering Vol 4, No 2 (2022): JULY
Publisher : Universitas Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17977/um049v4i2p01-08

Abstract

This research describes the oscillation control based on a power system that takes the place of the traditional automatic voltage regulators for excitation control in addition to a multimachine power system. The design is built on equilibrium and a potent adaptive critic technique called decreasing time oscillation for each generator. The generators' local measurements serve as the sole basis for the feedback variables. For enhancing the dynamic performance and stability of the power grid under significant shocks that affected oscillation power stations, simulations on multi-machine power systems were shown to be effective.    
SYNCHRONOUS AC CHOPPER FOR UNIVERSAL MOTOR SPEED CONTROL USING FUZZY LOGIC Andi Setiawan; Widjonarko Widjonarko; Candrika Kumaratungga
Frontier Energy System and Power Engineering Vol 3, No 2 (2021): JULY
Publisher : Universitas Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17977/um049v3i2p13-24

Abstract

The use of Universal type motors is very commonly used, both in daily life and in research activities. The universal motor can be used as prime mover generator PMSG (Permanent Magnet Synchronous Generator), which in its application there are obstacles, namely the difficulty of stabilizing the speed due to the influence of changes in the load connected to the PMSG, this affects the output voltage generated by the system. In this case, a speed stabilizer system is needed to stabilize the output voltage generated based on the load given to the system. AC Chopper is one of the circuits that can be applied in a speed control system that functions as an AC-AC voltage regulator which is the input of the Universal motor. Synchronous AC Chopper is one type of AC Chopper circuit which according to previous research has better performance in terms of efficiency than Basic AC Chopper. As for this control system, Fuzzy Mamdani logic is flexible and has a tolerance on existing data with control results having a settling time of ±15 seconds and an average efficiency of 84.99%.
The Effect of Penetration Floating Photovoltaic On – Grid in Diponegoro Education Reservoir against Power Quality Distribution Network Karnoto Karnoto; Hermawan Hermawan; Pangestuningtyas Diah Larasati; Ali Zaenal Abidin
Frontier Energy System and Power Engineering Vol 4, No 1 (2022): JANUARY
Publisher : Universitas Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17977/um049v4i1p12-16

Abstract

Diponegoro University is one of the universities that support the research, development, and utilization of renewable energy in Indonesia. The Diponegoro educational reservoir is one of the facilities at Diponegoro University that can be developed as a floating photovoltaic. The potential of the Diponegoro educational reservoir as a floating photovoltaic on-grid is 1.846 kWp. Penetration of floating photovoltaic in the power grid can affect the power quality of the system. This paper discusses the effect of floating photovoltaic penetration in the education reservoir in Diponegoro on the 20 kV distribution network using ETAP software. In this study, the penetration of floating photovoltaic capacity connect to the distribution network is 0%, 10%, 20%, 30%, and 40%. Penetration of floating photovoltaic can cause a decrease in power factor and losses in the distribution system. The maximum penetration of floating photovoltaic in the education reservoir in Diponegoro in the 20 kV distribution system is 30% with the injected capacity of floating photovoltaic is 1.121,3 kWp and the power factor in of the network is 0,867. Penetration over 30% can cause the system power factor to be less than the allowable power factor standard