cover
Contact Name
Intan Maulina
Contact Email
intanmaulina1509@gmail.com
Phone
+6281377776163
Journal Mail Official
ielektiese@gmail.com
Editorial Address
Jl. Setia Luhur LK V No.18 A Medan Helvetia
Location
Unknown,
Unknown
INDONESIA
Elektriese: Jurnal Sains dan Teknologi Elektro
ISSN : 20866933     EISSN : 28303512     DOI : https://doi.org/10.47709/elektriese
Elektriese: Jurnal Sains dan Teknologi Elektro merupakan Jurnal Nasional yang mempublikasikan karya ilmiah terbaik berdasarkan proses seleksi di bidang sains dan teknologi yang berfokus pada penerbitan makalah berkualitas. Artikel yang diserahkan akan ditinjau oleh komite teknis Jurnal. Semua artikel yang dikirimkan harus berupa laporan asli atau hasil kegiatan yang telah dilakukan sebelumnya, eksperimental atau teoritis, dan akan diulas oleh mitra bestari. Elektriese: Jurnal Sains dan Teknologi Elektro memiliki tema penelitian bidang Sains, Matematika, Biologi, Fisika, Kimia, IPA, dan Teknik Elektro, Sipil, Mesin, Lingkungan, Arsitek, Industri.
Articles 172 Documents
Implementasi Pengaturan Kecepatan Motor DC dengan Memanfaatkan Sensor Jarak pada Harbour Mobile Crane: Implementation of DC Motor Speed ??Control Using Proximity Sensors on a Harbour Mobile Crane Novita Anjarsari; Hendro Agus Widodo; Anggara Trisna Nugraha
Elektriese: Jurnal Sains dan Teknologi Elektro Vol. 16 No. 02 (2026): Atikel Riset Edisi October 2026
Publisher : Yayasan Cita Cendekiawan Al Khwarizmi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47709/elektriese.v16i02.9806

Abstract

Loading and unloading activities at ports utilize cranes to move containers. One type of crane employed is the Harbour Mobile Crane (HMC). The component of an HMC that grips the container is called a spreader. At each of the four corners of the spreader, there are "flippers" designed to help position the spreader onto the container. Observations indicate that these flippers frequently break because operators, using the joystick, move the spreader at an excessively high speed, causing it to collide with the container. To address this, a speed control system for the spreader—regulated via a proximity sensor—has been implemented. The objective of this final project is to explore the design and operational mechanism of an HMC prototype. The methodology began by identifying the issue: flippers had to be replaced 857 times in 2021 alone. This was followed by a literature review, the development of a design concept, and the construction of an HMC prototype, which was then tested under no-load conditions and evaluated for anti-sway performance. Once the prototype was completed, repeated testing was conducted to optimize its functionality. The test results align with the design concept: when the joystick is pulled backward, the motor reverses, causing the spreader to rise at a stable speed. When the joystick is pushed forward, the motor rotates forward, lowering the spreader; as it approaches a distance of 2 cm, the speed decreases. At this point, the motor can no longer rotate forward—it can only rotate in reverse when the joystick is pulled back. An HC-SR04 ultrasonic sensor is mounted on the spreader to detect distance. The device operates as intended: as the spreader descends, the motor slows down until it stops, while during ascent, the motor maintains a stable speed. Distance and speed are monitored via a 16x2 LCD screen.
Prototipe Sistem Automatic Switch pada Sistem Redundant Pump Cooling Tower Berbasis Mikrokontroler: Microcontroller-Based Automatic Switch System Prototype for Redundant Cooling Tower Pump Systems Septya Rizki Amelia; Hendro Agus Widodo; Anggara Trisna Nugraha
Elektriese: Jurnal Sains dan Teknologi Elektro Vol. 16 No. 02 (2026): Atikel Riset Edisi October 2026
Publisher : Yayasan Cita Cendekiawan Al Khwarizmi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47709/elektriese.v16i02.9808

Abstract

The cooling system of an injection molding machine plays a critical role in the production process by preventing overheating during injection molding. If the cooling system malfunctions or ceases to operate for even 5 to 10 minutes, the mold becomes overheated, causing the molded parts to stick—a scenario that results in both lost production time and wasted material. To address this, a redundant cooling tower pump system has been developed, incorporating an alarm and an auto-start feature to ensure continuous cooling operation. The system utilizes several sensors to monitor key parameters: a pressure transmitter to measure water pressure, a PZEM004T sensor to track voltage, current, and power consumption of the pump motor, and a thermocouple to monitor the motor's temperature. An Arduino Mega microcontroller serves as the central processing unit for the entire system, with sensor data displayed on an LCD screen. In the event of a failure in the primary pump, a relay automatically activates the backup pump while simultaneously triggering a buzzer as an alarm (and vice versa). Testing and observation, evaluated against a set of success criteria, confirm that this microcontroller-based automatic switching system for redundant pumps functions effectively. By providing an automatic switch mechanism, the system protects the pumps from catastrophic failure, improves operational efficiency for personnel, and simplifies the monitoring process.