Search results for , issue "Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik" : 5 Documents clear
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA Mhd. Rafli Perdana; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (205.885 KB)

Abstract

Medical devices are divices that are always in a ready to use condition and can function properly. This requires the Sari Mutiara University Integrated Laboratory to assist and medical equipment as effectively and efficiently as possible. This study aims to look at the syringe pump monitoring system in the USM-Indonesia Integrated Lab.Descriptive research method. Syringe pump tools and materials, questionnaire instruments used to conduct direct interviews with officers in the integrated laboratory, observation and documents.The results of this study indicate that all medical equipment including the syringe pump in the USM-Indonesia integrated Lab has never been maintained because there has not been a maintenance program for the medical equipment in the Lab. Integrated suggestions for syringe pump equipment and other health equipment to be maintained in the form of heating the appliance twice a week so that the tool is always in a condition that can function properly and has a longer service life, it is necessary to make SOP for operating the syringe pump tool and other tools.
RANCANG BANGUN ALAT UKUR BERAT BADAN OTOMATIS BERBASIS ANDROID Isagani Zakaria Tarigan; Salomo Sijabat
JURNAL MUTIARA ELEKTROMEDIK Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (263.806 KB)

Abstract

Design and construction of an Android-based automatic weight measurement tool has been carried out. This research was made because of the demands for sophisticated medical support equipment with all the capabilities it has that continues to develop so that effective and efficient medical support equipment can be produced. This tool is designed with the aim of providing information about the measurement data of weight and height to users. Measurement results data will be sent to Android in the form of messages to be stored using the android database system storage.This research method uses qualitative methods, namely: study literature and literature and conduct experiments on the circuit design made, then test the function of the tool with a scale to determine the accuracy of the work of this tool. This tool is made by utilizing the Load Cell sensor as conversion then will sent via GSM SIM 800L, and the data is displayed via the application and SMS on the patient's Android.The test results show that the weight obtained is the result of the load cell sensor measurement. seen the percentage error value for each measurement, which allows the sensor to read errors and possible interference from the compiler program. As long as the% error does not exceed 3%, the module design and build an automatic weight measuring instrument, can be used properly
ANALISA PEMELIHARAAN BABY INCUBATOR M. Ariansyah Putra; Harold Situmorang
JURNAL MUTIARA ELEKTROMEDIK Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Medical devices are devices that are always in a ready-to-use condition. and can function properly. This requires the Integrated Laboratory of Sari Mutiara University to be able to manage and maintain medical equipment as effectively and efficiently as possible. If this maintenance function is running well, then the quality of the medical equipment used will be good. This research aims to determine the maintenance and care system for the Baby incubator device, know what the Baby incubator is, and to know the principles of work.This research is a descriptive analysis with qualitative methods. The instrument used is by conducting in-depth interviews, observation and documents. The results of this study indicate that in its implementation, the maintenance system cannot be run properly, due to limited technical personnel, lack of training, insufficient maintenance costs, maintenance SOPs are not in accordance with procedures. Planning, organizing, and monitoring are not well implemented so that the preventive and corrective maintenance systems cannot run properly.
ANALISA PRINSIP KERJA FLOW SENSOR DALAM MENGETAHUI VOLUME TIDAL MESIN ANASTESI VENTILATOR Kharisda Novtri Gratia Gulo; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (340.35 KB)

Abstract

Flow sensors have an important role in ventilator anesthesia machines, where flow sensors function to monitor air flow and pressure to obtain the amount of air volume and pressure delivered to the patient. If the volume of air entering the patient does not match the capacity of the patient's lungs, it can endanger the patient. So that a flow sensor is needed in order to know the accuracy of the volume that will be given to the patient.
ANALISA KALIBRASI ALAT PHOTOTHERAPY UNIT MENGGUNAKAN PHOTOTHERAPY RADIOMETER Jesni Juwita Mendrofa; Yulizham Yulizham
JURNAL MUTIARA ELEKTROMEDIK Vol 5 No 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (289.526 KB)

Abstract

Jaundice in newborns from January 2013 to December 2015, with a sample size of 223 babies. To treat jaundice in babies, Phototherapy is used. Phototherapy is the first action therapy for newborns with hyperbilirunemia. The provision of effective phototherapy is the main factor in the rapid management of hyperbilirubinemia.