cover
Contact Name
Noerman Adi Prasetya
Contact Email
noerman@borneo.ac.id
Phone
+6281233242398
Journal Mail Official
borneo.cesj@gmail.com
Editorial Address
Program Studi Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan Jl. Amal Lama No.1 Kota Tarakan Kalimantan Utara
Location
Kota tarakan,
Kalimantan utara
INDONESIA
Civil Engineering Scientific Journal
ISSN : 29623308     EISSN : 29631335     DOI : https://doi.org/10.35334/cesj.v1i2
Core Subject : Engineering,
Civil Engineering Scientific Journal (CESJ) is a scientific journal published by the Civil Engineering Study Program, University of Borneo Tarakan. CESJ is a forum for civil engineering students to publish scientific works, research results, literature, and analytical studies that focus on the field of civil engineering. CESJ published three times a year (January, May, and September). The focus and scope of this journal are structural engineering, concrete & building material, transportation engineering, geotechnical engineering, water resources engineering & coastal engineering, construction engineering & management
Articles 5 Documents
Search results for , issue "Vol 3, No 1 (2024): Civil Engineering Scientific Journal" : 5 Documents clear
PENAMBAHAN FLY ASH PADA BETON BERBAHAN TAMBAH SP 1,5% Ilhamsaid, Trio Aldy
Civil Engineering Scientific Journal Vol 3, No 1 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i1.5782

Abstract

ABSTRACT : Numerous research and experiments in the field of concrete have been conducted, aiming to achieve high-quality concrete by enhancing the quality of its constituent materials, such as the hardness of aggregates and the fineness of cement. Concrete quality improvement can be achieved by incorporating partial cement replacement materials, such as fly ash, and chemical additives, including superplasticizers. The primary objective of this study is to determine the optimal concrete mix ratio and assess the compressive strength of concrete utilizing superplasticizers and fly ash. At 28 days of age, the maximum compressive strength was achieved in concrete with a 15% fly ash mix, yielding 406 kg/cm2, compared to standard concrete with 0% fly ash, which had a compressive strength of 379 kg/cm2. The compressive strength for a 5% fly ash mix was 356 kg/cm2, and for a 10% fly ash mix, it was 383 kg/cm2. This study demonstrates that concrete with a 15% fly ash substitution at 28 days of age produces higher compressive strength than 5% and 10% fly ash substitutions. There was a 1.09% increase in compressive strength for the 10% fly ash variation and a 7.29% increase for the 15% fly ash variation. From the results obtained, the most optimal variation was the 15% fly ash substitution for the compressive strength of concrete at 28 days of age.Kata kunci : Concrete, Fly ash, Compressive Strength, Superplasticizer ABSTRAK : Beberapa riset dan eksperimen di bidang beton telah banyak dilakukan salah satu upaya untuk mendapatkan beton mutu tinggi itu adalah dengan meningkatkan mutu material pembentuknya, misalnya kekerasan agregat dan kehalusan semen. Peningkatan mutu beton dapat dilakukan dengan memberikan bahan pengganti sebagian semen, diantaranya adalah abu terbang (fly ash) dan bahan tambah kimia diantaranya superplasticizer. Tujuan utama dari penelitian ini adalah untuk mendapatkan perbandingan campuran beton dan mengetahui besar kuat tekan beton yang telah menggunakan zat kimia superplasticizer dan fly ash. pada umur 28 hari Kuat tekan maksimum dicapai pada beton dengan campuran fly ash 15% sebesar 406 kg/c , sedangkan beton normal 0% kuat tekan beton sebesar 379 kg/c , untuk campuran fly ash 5% kuat tekan beton sebesar 356 kg/c  dan campuran fly ash 10% kuat tekan beton sebesar 383 kg/c . Dari penelitian ini beton yang diberi abu terbang sebanyak 15% pada umur 28 hari menghasilkan kuat tekan yang lebih tinggi dibandingkan dengan subtitusi fly ash 5%,10%, Terjadi peningkatan kuat tekan beton sebesar 1,09% pada variasi BFA 10%, peningkatan kuat tekan beton sebesar 7,29% pada variasi BFA 15%. Dari hasil yang dilakukan dari tiga variasi menggunakan fly ash dalam beton didapat variasi yang paling optimum berada pada subtitusi fly ash 15% pada kuat tekan beton umur 28 hari.Kata Kunci : Beton, Fly ash, Kuat Tekan, Superplasticizer
FREKUENSI NATURAL GETARAN BEBAS TAK TEREDAM STRUKTUR GEDUNG TINGGI MENGGUNAKAN METODE ZALKA DAN SAP 2000 Rizaldi, Adi; Bahar, Adwan; Safrudin, Safrudin; Natsir, Rahmat
Civil Engineering Scientific Journal Vol 3, No 1 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i1.5006

Abstract

ABSTRACT: In tall building structures with a framed-tube structural system, the role of shear walls is most efficient in reducing the effect of lateral loads. A simple analytical calculation method using the Zalka method was developed to calculate the natural frequencies of tall building structures with a continuous system model consist of frames, shear walls, and cores. This continuous system model in tall building structures can be replaced by the idealization of cantilever beam structures with fixed-free end support conditions which represent the overall characteristics of the tall building structures. The aim of this research in this paper is to investigate the extent of the accuracy and efficiency of the results of natural frequency of 30 stories reinforced concrete building structure with the continuous system model above using the Zalka method compared to the SAP 2000 output. The results of this research are expected to provide in-depth insight into the effectiveness and the the readiness of the Zalkas method in determining the natural frequency of tall building structures due to lateral loads. Based on the results of this research, it was found that the natural frequency of a 30 stories reinforced concrete building structure using the Zalka method has error value equal to 4,884% compare to output from SAP 2000. This error value still in the range of acceptable value equal to 7% and shows us that Zalka method has acceptable accuracy.Keywords: Free Vibration, Natural Frequency, Tall Building, Frames-Tube System, Shear WallABSTRAK: Pada struktur bangunan tinggi dengan sistem struktur rangka-tabung, peranan dinding geser paling efisien dalam mereduksi pengaruh beban lateral. Metode perhitungan analitik sederhana menggunakan metode Zalka dikembangkan untuk menghitung frekuensi natural struktur bangunan tinggi dengan model sistem menerus yang terdiri dari rangka, dinding geser, dan inti bangunan. Model sistem menerus ini pada struktur bangunan tinggi dapat digantikan oleh idealisasi struktur balok kantilever dengan kondisi tumpuan jepit-bebas yang mewakili keseluruhan karakteristik pada struktur bangunan tinggi tersebut. Tujuan penelitian dalam penulisan ini adalah menyelidiki sejauhmana akurasi dan efisiensi hasil analisis frekuensi natural struktur gedung beton bertulang 30 lantai dengan model sistem menerus di atas menggunakan metode Zalka dibandingan hasil luaran (output) SAP 2000. Hasil penelitian ini diharapkan dapat memberikan wawasan mendalam tentang efektivitas dan kesiapterapan metode Zalka dalam penentuan frekuensi natural struktur bangunan tinggi akibat beban lateral. Berdasarkan hasil penelitian ini, diperoleh frekuensi natural struktur gedung beton bertulang 30 lantai menggunakan metode Zalka memiliki nilai kesalahan 4,884% dari hasil luaran (output) SAP 2000. Nilai kesalahan ini masih dalam batas yang wajar yaitu 7% dan menunjukkan bahwa metode Zalka mempunyai akurasi yang dapat diterima. Kata kunci: Getaran Bebas, Frekuensi Natural, Struktur Bangunan Tinggi, Sistem Rangka-Tabung, Dinding Geser
ANALISIS DEBIT BANJIR DRAINASE JALAN PATTIMURA KOTA TARAKAN DAN PENGARUHNYA TERHADAP KAPASITAS SALURAN Ruslan, Ruslan; Amiruddin, Aswar; Faizal, Rahmat
Civil Engineering Scientific Journal Vol 3, No 1 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i1.5041

Abstract

ABSTRACT: Tarakan City has a large problem of land conversion which results in a decrease in the infiltration area. Jalan Pattimura, Pamusian Kelurahan is one of the points in Central Tarakan District that has the potential for flooding due to high rainfall intensity. The purpose of this study is to calculate the flood discharge Q25, Q50 and Q100 and to evaluate the channel capacity against the flood discharge. The method used to calculate the discharge is the modified rational method. The design flood discharge with a return period of 25, 50 and 100 years in the catchment area of drainage channel 1 is calculated using the modified rational method is 0,112 m3/sec for Q25, 0,115 m3/sec for Q50 and 0,117 m3/sec for Q100. Furthermore, the design flood discharge in the catchment area of drainage channel 2 is calculated using the modified rational method is 0,111 m3/sec for Q25, 0,113 m3/sec for Q50 and 0,115 m3/sec for Q100. Based on the evaluation of the existing channel conditions of Jalan Pattimura, Pamusian Kelurahan, Tarakan City, it was obtained that the existing channel capacity with the existing channel height is able to pass a discharge of 0,366 m3/sec for Drainage Channel 1 and 0,312 m3/sec for Drainage Channel 2 so it can be concluded that the current channel is still able to pass the discharge Q25, Q50 and Q100 years. Keywords: Drainage, flood discharge, channel capacity ABSTRAK: Kota Tarakan memiliki masalah alih fungsi lahan yang besar yang berakibat pada berkurangnya daerah resapan. Jalan Pattimura, Kelurahan Pamusian merupakan salah titik di Kecamatan Tarakan Tengah yang memiliki potensi banjir akibat intensitas hujan yang tinggi. Tujuan penelitian ini untuk menghitung debit banjir Q25, Q50 dan Q100 dan melakukan evaluasi kapasitas saluran terhadap debit banjir. Metode yang digunakan untuk menghitung debit adalah rasional modifikasi. Debit banjir rencana periode ulang 25, 50 dan 100 tahun pada daerah tangkapan saluran drainase 1 dihitung menggunakan metode rasional modifikasi adalah 0,112  m3/dtk untuk Q25, 0,115 m3/dtk untuk Q50 dan 0,117 m3/dtk untuk Q100. Selanjutnya, debit banjir rencana pada daerah tangkapan saluran drainase 2 dihitung menggunakan metode rasional modifikasi rasional adalah 0,111  m3/dtk untuk Q25, 0,113 m3/dtk untuk Q50 dan 0,115 m3/dtk untuk Q100. Berdasarkan evaluasi terhadap kondisi saluran eksisting Jalan Pattimura, Kelurahan Pamusian, Kota Tarakan diperoleh kapasitas saluran eksisting dengan tinggi saluran yang ada saat mampu melewatkan debit 0,366 m3/dtk untuk Saluran Drainase 1 dan 0,312 m3/dtk untuk Saluran Drainase 2 sehingga dapat disimpulkan saluran yang saat ini masih mampu melewatkan debit Q25, Q50 dan Q100 tahun.Kata kunci: Drainase, debit banjir, kapasitas saluran
PEMANFAATAN LIMBAH FLY ASH DAN BOTTOM ASH SEBAGAI CAMPURAN BETON Hestianita, Devie
Civil Engineering Scientific Journal Vol 3, No 1 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i1.5772

Abstract

ABSTRACT : PLTU waste produces a large enough amount that requires management so as not to cause environmental problems. In the field of construction, fly ash and bottom ash have the potential to be developed, one of which is their use as a base material. Potential if developed, one of which is its use as a basic ingredient in the concrete making mixture. This research aims to determine the percentage of increase or decrease in compressive strength of concrete produced with the addition of fly ash and bottom ash with a variation of 0%. Fly ash and bottom ash have variation of 0%, 7.5%, 15%, and 22.5%, with the age of 14 days, 21 days, and 28 days. 14 days, 21 days, and 28 days for each combination of mixtures with a plan quality of K-250 and know the comparison of compressive strength of concrete without mixtures and using a mixture of fly ash and bottom ash. Based on the research showed that the substitution of fly ash as cement and bottom ash as fine aggregate with a percentage of 0%, 7.5%, 15%, and 22.5%, the compressive strength of days-old concrete was 236 kg/cm2, 193 kg/cm2, 175 kg/cm2, 148 kg/cm2, 21 days-old concrete compressive strength values of 168 kg/cm2, 257 kg/cm2, 210 kg/cm2, 185 kg/cm2 and the compressive strength of concrete aged 28 days by 324 kg/cm2, 281 kg/cm2, 237 kg/cm2, 212 kg/cm2. The existence of the substitution of fly ash and bottom ash to normal concrete by 7.5%, 15%, and 22.5% decreased in strength as percentage of fly ash substitution to cement and bottom ash to normal concrete increased. Fly ash is to cement, and bottom ash is to sand. The greater the substitution of fly ash and bottom ash substitution to normal concrete, the more the strength of concrete descreased due to the reduced compositon of fine aggregate gradation and cement to normal concrete.  Keywords : Concrete, Compressive Strength, Fly Ash, Bottom Ash ABSTRAK: Limbah PLTU ini menghasilkan jumlah yang cukup besar sehingga memerlukan pengelolaan agar tidak menimbulkan masalah lingkungan. Dalam  bidang kontruksi abu terbang (fly ash) dan abu dasar (bottom ash) merupakan suatu hal yang sangat potensial bila dikembangkan, salah satu penggunaannya sebagai bahan dasar campuran pembuatan beton. Penelitian ini bertujuan untuk mengetahui persentase peningkatan atau penurunan kuat tekan beton yang dihasilkan dengan tambahan fly ash dan bottom ash dengan variasi sebesar 0%, 7,5%, 15%, dan 22,5% dengan umur 14 hari, 21 hari serta 28 hari untuk setiap kombinasi campuran dengan mutu rencana K-250 dan mengetahui perbandingan kuat tekan beton tanpa campuran dan memakai campuran fly ash dan bottom ash. Berdasarkan dari hasil penelitian dengan substitusi fly ash sebagai semen dan bottom ash sebagai agregat halus dengan persentase 0%, 7,5%, 15%, dan 22,5%, diperoleh nilai kuat tekan beton umur 14 hari sebesar 236 kg/cm2, 193 kg/cm2, 175 kg/cm2, 148 kg/cm2, nilai kuat tekan beton umur 21 hari sebesar 168 kg/cm2, 257 kg/cm2, 210 kg/cm2, 185 kg/cm2 dan nilai kuat tekan beton umur 28 hari sebesar 324 kg/cm2, 281 kg/cm2, 237 kg/cm2, 212 kg/cm2. Adanya subsitusi fly ash dan bottom ash terhadap beton normal sebesar 7,5%, 15%, dan 22,5% mengalami penurunan kekuatan seiring bertambahnya persentase substitusi fly ash terhadap semen dan bottom ash terdahap pasir. Semakin besar substitusi fly ash dan bottom ash terhadap beton normal, semakin menurun kekuatan beton disebabkan karena berkurangnya komposisi gradasi agregat halus dan semen terhadap beton normal.Kata Kunci : Beton, Kuat Tekan, Fly Ash, Bottom Ash
ANALISIS DAYA DUKUNG TIANG PANCANG (STUDI KASUS : PROYEK PEMBANGUNAN GEDUNG SEKOLAH SMPN 7 TARAKAN) Septiana, Endah Dwi
Civil Engineering Scientific Journal Vol 3, No 1 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i1.5780

Abstract

ABSTRACT : In principle, a building cannot be built on land that is unable to accept the burden of the building because it will cause a settlement from the construction. This research was carried out in the SMPN 7 Tarakan building construction project to find out the bearing capacity using static methods, dynamic methods and finite element method (FEM). Results of calculation of the bearing capacity based on the static method, the greatest value on the S-5 sondir point with Meyerhoff method is 2252,96 tons and the smallest on the S-1 sondir point with Aoki de Alancer method is 502,73 tons. Based on the dynamic method, the greatest one on B-19-C point with Engineering New Record method is 1994,45 tons while the smallest on B-19-F point with Janbu method is 484,42 tons. On the finite element method (FEM), the value of bearing capacity is 1850,18 tons. Safety factor (SF) on static method get the greatest value on S-5 sondir point with Mayerhoff method is 6,47 and the smallest on S-1 sondir point with Aoki de Alancer method is 1,44. On dynamic method, the greatest value on B-19-C point with Engineering New Record method is 5,73 and the smallest on B-19-F point with Janbu method is 1,39. And the safety factor with Finite Element Method (FEM) is 5,32.  Keywords : Bearing capacity, Static method, Dynamic method, Finite element method, Safety factor. ABSTRAK: Pada prinsipnya suatu gedung tidak dapat dibangun ditanah yang tidak mampu menerima beban gedung tersebut karena akan menyebabkan terjadinya penurunan dari konstruksi tersebut. Tujuan dari penelitian di Proyek Pembangunan Gedung Sekolah SMPN 7 Tarakan ini, untuk mengetahui kapasitas daya dukung tiang pancang dengan menggunakan metode statis, metode dinamis dan metode elemen hingga (MEH). Hasil perhitungan daya dukung tiang kelompok dengan menggunakan metode statis yang terbesar pada titik sondir S-5 metode Mayerhoff sebesar 2252,96 ton dan yang terkecil di titik sondir S-1 dengan metode Aoki de Alancer sebesar 502,73 ton. Daya dukung tiang kelompok menggunakan metode dinamis yang terbesar pada titik B-19-C metode Engineering New Record (ENR) sebesar 1994,45 ton sedangkan yang terkecil pada titik B-19-F metode Janbu sebesar 575,831 ton. Dengan metode elemen hingga (MEH) didapatkan nilai daya dukung tiang kelompok sebesar 1850,18 ton. Angka keamanan (SF) pada metode statis menghasilkan nilai SF terbesar pada titik sondir S-5 metode Mayerhoff sebesar 6,47 dan terkecil pada titik sondir S-1 metode Aoki de Alancer sebesar 1,44. Pada metode dinamis menghasilkan nilai SF terbesar pada titik B-19-C metode Engineering New Record sebesar 5,73 dan terkecil pada titik B-19-F metode Janbu sebesar 1,65 Dan dengan metode elemen hingga (MEH) didapatkan nilai SF sebesar 5,32.Kata Kunci : Daya dukung pondasi, Metode statis, Metode dinamis, Metode elemen hingga, Angka keamanan

Page 1 of 1 | Total Record : 5