cover
Contact Name
Rudi Kurnianto
Contact Email
rudi.kurnianto@ee.untan.ac.id
Phone
+6285252665807
Journal Mail Official
j3eit@untan.ac.id
Editorial Address
Jl. Prof. Dr. Hadari Nawawi, Pontianak 78124, Indonesia
Location
Kota pontianak,
Kalimantan barat
INDONESIA
Journal of Electrical Engineering, Energy, and Information Technology
ISSN : -     EISSN : 30261856     DOI : http://dx.doi.org/10.26418/j3eit.v11i2
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) (E-ISSN: 3026-1856) is the latest name for the JTE UNTAN, which underwent a name change. This journal has been in circulation within UNTAN since 2013 under its previous name. The name change reflects an evolution in the topics covered by the journal, encompassing the fields of electrical engineering, energy, and information technology. With the establishment of J3EIT, it is expected to become a significant resource for the academic and research community in this discipline, fostering the exchange of knowledge and innovation among professionals in the field of electrical engineering and related areas. By consistently publishing high-quality scientific papers, this journal is expected to play a vital role in advancing knowledge in its field. J3EIT is published three times a year, April, August and December.
Articles 24 Documents
Search results for , issue "Vol 5, No 1: Januari 2017" : 24 Documents clear
ANALISIS RATA-RATA LINTASAN REDAMAN MODEL PROPAGASI PADA LAYANAN BASE TRANSEIVER STATION (BTS) BERSAMA AREA KOTA PONTIANAK Rudi Sartino .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.18904

Abstract

Selecting a good propagation model is quite difficult for a wireless communication design. In this study, an approach to calculate propagation attenuation circuit which was appropriate with characteristics in Pontianak area was done by a means of applying certain formula, for instance through Okumura-Hatta model and Walfisch-Ikegami model. This study aims at identifying the influence of antenna’s beam distance and signal reception at Mobile Station (MS) towards attenuation value, implementing Okumura-Hatta model and Walfisch-Ikegami model, and analyzing the average value of propagation attenuation circuit on Collective BTS (Base Transceiver Station) service in Pontianak. Based on the measurement, calculation, and analysis which was done in Jalan Husain Hamzah RT.05/RW.01 Kelurahan Paal Lima, Kecamatan Pontianak Barat, it was revealed that the average values of attenuation circuit for Telkomsel by distance 0.75 Km, 1.5 Km, 2.25 Km using Okumura-Hatta model were 125.42 dB, 142.58 dB, and 153.24 dB, with receptivity averages were - 85.42 dBm, -102.58 dBm, and -113.24 dBm. In Walfisch-Ikegami propagation model, the average value of attenuation circuit were  136.23 dB, 149.06 dB, 154.80 dB, with receptivity averages reached –96.23 dBm, -109.06 dBm, and -114.80 dBm. Meanwhile, for Three provider by distance 0.75 Km, 1.5 Km, and 2.25 Km using Okumura-Hatta model, it was obtained an average value of attenuation circuit as much as 124.31 dB, 141.99 dB, and 152.98 dB with receptivity averages were –84.01 dBm, -101.69 dBm, and -112.98 dBm. In Walfisch-Ikegami model, the average value of attenuation circuit were 135.80 dB, 146.52 dB, and 153.77 dB, with receptivity averages as much as –95.50 dBm, -106.22 dBm, -113.47 dBm.   Key words: Attenuation propagation, RSCP, Okumura-Hatta, Walfisch-Ikegami
ANALISIS PERUBAHAN PITA FREKUENSI 1800 DAN 2100 MHZ TERHADAP PERFORMANSI JARINGAN BASE TRANSCEIVER STATION Syarif Muhammad Faisal .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.19686

Abstract

Abstract - In its application, the mobile system has its limitations    and is    often    experienced disturbances  (interference)  like  limited  talk channels as the result of the increasing number of cellular communication technology user, which is led to „block call‟. The problem with Radio Frequency   (RF)   signal   reception   is   also   an important factor in wireless communication system. The low quality of signal levels caused the frequent call failure or „drop call‟. Therefore, it is necessary to have sustainable monitoring system and analysis towards the performance of the  network system, especially after the government produce the For a review of Necessary Process Monitoring and analysis of the Sustainable Network system, especially with the regulation of the Ministry of Communication  and  Information  No.  19  /  2013 About  "  Mekanisme  dan  Tahapan  Pemindahan Alokasi Pita Frekuensi Radio Pada Penataan Menyuluruh Pita Frekuensi Radio 2100 MHz.” The monitoring and performance analysis used Key Performance Indicator (KPI) parameters as a benchmark for the network performance and a description   of  the   cellular   system  Quality   of Service (QoS). The KPI parameters are Call Setup Success Rate (CSSR), Drop Call Rate (DCR), Handover Success rate (HSR), and Traffic Channel Congestion rate (TCH Congestion rate). The results of the test drive of five BTS before and after frequency refarming in 1800 and 2100 MHz, the percentage of SDCCH blocking was not high enough, as determined by PT. Indosat Ooredoo, which is not more than 2%. There are 5 BTS to be observed:   BTS  Nipah  Kuning,   BTS  Perum  1 Jeruju, BTS Martadinata, BTS Gertak 1 and BTS Gang Semangka.   Keywords  : Frequency band and Parameter Key Performance Indicator (KPI)
ANALIS PREDIKSI PENERIMAAN LEVEL SINYAL PADA DAERAH SUB URBAN TERHADAP UNJUK KERJA JARINGAN GSM Muhammad Mudjiono .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.18903

Abstract

Sub-urban area is a suburban area (rural) with some of the barriers of trees, houses and buildings that are not too high under 5 level. Some of the causes of interruption of the call is limited channel reception level talks and the problem of RF signals (radio frequency) where the quality of the signal level is strongly influenced by local conditions damping propagation. The study was conducted in village siduk, districtsnanga tayap, north kayong district, Problems GSM network performance can be seen from the monitoring of traffic through NetAct software by using parameter-parameter above as: SDCCH Blocking, SDCCH Drop, Loss RF SDCCH, TCH Blocking, TCH Drop, and TCH RF Loss. Then do the calculation Prediction Reception signal level using Okomura-Hatta. Manual calculation results in BTS North Kayong siduk shows that the BTS antenna sector 1 with a power 27 W is obtained within a range of 3.2 km with a reception signal level -80 dBm, while the range desired by PT. Telkomsel is 3.5 Km, then power must be increased to 34.62 W. In sector 2, the transmit power of 27 W, within a range of 3.2 km, with the reception signal level -80 dBm, the desired range of 3.8 Km, power must be increased to 35.80 W. in the third sector, the transmit power of 26 W, within a range of 3.1 km, with the reception signal level -80 dBm, the desired range 3.5 Km, power should rise to 34.26 W. from the results of calculations can be concluded that the performance of the BTS antennas siduk north Kayong less than the maximum because of the decreasing transmission power due to the loss of damping propagation in sub urban Reviewed sector antenna 1 is (2 dBm), sector 2 is (3 dBm), sector 3 is (3 dBm). But in general is still quite good. Key word : Sub- urban , NETACT , Traffic , Okomura – Hatta.
ANALISA PERANCANGAN ANTENA OMNI VERTIKAL SEBAGAI TRANSCEIVER PENGUAT ROUTER WIFI DENGAN FREKUENSI 2,4 GHZ Muhammad Hanafi .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.18517

Abstract

Omnidirectional antenna (Omni) is a type of antenna that has a pattern radiance whole or in all directions in the amount of 360 ° in the vertical position, as it has a beam thorough omni antenna does not have a coverage area that is too far away, then this antenna is more devoted to relations wireless communication indoors antenna which is paired to a wifi router that functioned as an amplifier reconfigured so this antenna will work as a transceiver amplifier with a working frequency of 2.4 GHz for wireless LAN (local area network). The parameters that must be considered in designing antennas for wireless LAN is working frequency, Input Impedance, SWR (Standing Wave Ratio) and Gain, and omni antenna designed to have input impedance parameter value 34.65 + J 7.24 ohms, the SWR 1.44 and Gain 8.32 dB. In the connectivity test used the command line via the command prompt provided by MS-DOS on a computer with a Windows-based operating system, and testing applications use power beam analyzer wifi version of Android-based smartphones. To test the speed of the download and upload, conducted through speedtest.net on two different networks that wifi.id network with download speeds of 15.22 Mbps, upload 10.48 Mbps network and the Faculty of Engineering at 1.09 Mbps download speed, upload 0.11 Mbps, which is influenced by the speed speedtest maximum value and minimum speeds provided by ISP (internet Service Provider). Keywords : Antena Omni, Transceiver, Router Wifi, frekuensi 2,4 GHz
ANALISIS KEY PERFORMANCE INDICATOR (KPI) JARINGAN TELEKOMUNIKASI GSM PADA PT. HUTCHISON 3 INDONESIA (H3I) PONTIANAK Khusnul Khotimah .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.19366

Abstract

ABSTRACT- The development of GSM technology is expected to be able to accommodate data and voice services. Therefore the application of the GSM network is necessary to perfect design and optimization of the network, so that it can produce optimal  network  and  profitable.  Network performance measurement is performed to determine network performance at PT. Hutchison 3 Indonesia (H3I) Pontianak on the Khatulistiwa Plaza area without  and with  repeater. Drive Test is required to collect the data from the measurement of signal quality of a network. GSM network performance is analyzed based on KPI parameters are call statistics obtained using TEMS software, KPI parameters consist of CSSR, CSR and CDR. The results of Drive Test does not use repeaters obtained CSSR 100%, CSR 80% and the CDR of 20%, whereas when using a repeater obtained CSSR 100%, CSR 97% and CDR 3%, the data retrieval process performed three times with the result was not optimal, it caused kind of repeaters are using do not compatible with Node B frequency. Node B to the 3G network is 2100 MHz, while the repeater is work at frequency 1800 MHz. The result of using repeater for this network, performance states are in good condition. Keywords: Network performance, drive test, CSSR, CSR, CDR.
Analisis Pengendalian Gerak Model Robot Keseimbangan Beroda Dua Menggunakan Pengendali Linear Quadratic Regulator (LQR) Modestus Oliver Asali .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.19902

Abstract

Abstrak- Perkembangan penelitian tentang robot mendapat kemajuan yang pesat beberapa dekade terakhir ini. Salah satu robot yang mendapat perhatian serius belakangan ini adalah robot penyeimbang beroda dua yang berfungsi sebagai kendaraan masa depan bagi manusia karena memiliki kelebihan dalam hal emisi dan manuvernya. Dalam penelitian ini dicari pengendali LQR terhadap suatu robot penyeimbang dengan dua roda sehingga dapat digerakkan ke arah yang diinginkan oleh pengguna tanpa terjatuh. Dari hasil penelitian, didapat bahwa metode LQR cukup handal dalam mengendalikan sistem seperti ini. Sistem dapat bergerak menyeimbangkan dirinya dalam waktu yang cukup singkat dan bergerak menuju arah yang diinginkan oleh operator. Kata kunci-robot keseimbangan beroda dua, pengendali LQR, pengendalian gerak, kendali optimal
Rancang Bangun Robot Pemain Musik Gamelan Menggunakan Mikrokontroler ATMega16 Handri Jir Azhar .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.17937

Abstract

Abstrak.--Robot musik gamelan adalah robot yang dapat memainkan gamelan pada bilah-bilah nada yang diinginkan dengan batas oktaf gamelan berjumlah 2 oktaf 15 nada. Robot musik gamelan mempunyai input berupa tombol perintah keypad 4×4, sensor posisi DC gear motor magnetic rotary encoder dan sensor limit switch sebagai pembatas jalur kereta. Perangkat pengendali menggunakan mikrokontroler Atmega 16. Perangkat penggerak robot gamelan adalah DC gear motor dan motor servo pemukul gamelan. Peran motor DC adalah untuk menggerakkan kereta agar bergeser kearah kiri atau kanan. Posisi putaran motor DC menggunakan sistem kendali tertutup proporsional derivatif (PD). Konstanta pengali PD diperoleh dari try dan error, dengan konstanta proporsional (Kp) = 5 dan konstanta derivatif (Kd) = 15. Nilai Kp dan Kd berfungsi untuk menentukan besarnya lebar pulsa yang berpengaruh terhadap kecepatan DC gear motor disaat DC gear motor memposisikan posisi diinginkan dari set point (SP). Apabila data posisi DC gear motor yang diperoleh/present value (PV) ≠ SP, maka posisi motor dapat menggunakan nilai toleransi error (Er) yaitu Er < 3 dan Er > -3. Nilai toleransi error bertujuan agar nilai PV pada posisi DC gear motor bisa mendekati nilai SP, yang menandakan bahwa posisi pemukul kereta telah berada pada area bilah nada yang ingin dituju. Motor servo sebagai penggerak pemukul gamelan akan memukul bilah nada apabila nilai posisi DC gear motor memenuhi syarat PV = SP atau syarat toleransi error. Kata kunci: Gamelan, mikrokontroler Atmega 16, magnetic rotary encoder, limit switch, DC gear motor, set point, present value, error.
EVALUASI PROFIL TEGANGAN DAN SUSUT DAYA PADA SALURAN UDARA TEGANGAN RENDAH (SUTR) DI KOMPLEK PERKANTORAN KABUPATEN SAMBAS M. Taufieq Haerwana .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.18993

Abstract

Abstrak - Komplek perkantoran Pemerintah Daerah Kabupaten Sambas perlu mendapatkan  perhatian khusus dalam pelayanan beban karena terdapat beban yang besar di daerah tersebut.  Besarnya jatuh tegangan pada jaringan listrik  pada SUTR (saluran udara tegangan rendah) merupakan salah satu sumber utama penyebab besarnya rugi-rugi daya aktif. Untuk mengetahui kondisi yang telah dipaparkan di atas perlu dilakukan analisis atau evaluasi terhadap jaringan tegangan rendah di lingkungan komplek perkantoran Pemerintah Daerah Kabupaten Sambas. Dari hasil perhitungan persentase jatuh tegangan pada masing-masing gardu dan mengaju pada ketentuan SPLN No.72 Tahun 1987 tentang Spesifikasi Desain Untuk Jaringan Tegangan Menengah (JTM) dan Jaringan Tegangan Rendah (JTR), dimana persentase jatuh tegangan pada jaringan tegangan rendah maksimum 4%. Terdapat beberapa bus yang memiliki persentase jatuh tegangan diatas 4%. Dari hasil, total rugi-rugi daya aktif yang terjadi pada jaringan tegangan rendah (JTR) Gardu perkantoran Pemerintah Daerah Kabupaten Sambas sebesar 40.925,716 Watt. Kata kunci :  SPLN, JTM, JTR, persentase jatuh tegangan, rugi-rugi daya aktif.
ANALISIS PERUBAHAN PHYSICAL TUNNING ANTENNA SECTORAL UNTUK MEMAKSIMALKAN LAYANAN JARINGAN GSM Imam Tarmizi .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.19843

Abstract

Perubahan physical tunning antenna sectoral pada 2 BTS dengan masing-masing 1 sektor antena. Proses perubahan dimulai pada BTS terdekat dengan area Komplek Bali Agung 3 dengan nama TB_Purnama2, pada BTS tersebut dilakukan perubahan dengan metode azimuth tilt yang merubah arah pancar antena sektor 3 yang melayani jaringan 3G dengan kondisi sebelum perubahan berada di 240o menjadi 280o, pengujian melalui drive test dengan merujuk parameter KPI yang digunakan PT. Telkomsel Pontianak untuk layanan 3G yaitu RSCP dan Ec/No dan menghasilkan peningkatan layanan jaringan GSM untuk RSCP dengan kualitas sangat baik 54.57% menjadi 91.10% dengan selebihnya kualitas baik 8.90% dan tidak ada kualitas cukup baik ataupun kualitas buruk pada area tersebut, sedangkan untuk parameter Ec/No mengalami kenaikan untuk kategori sangat baik 28.10% dengan nilai sebelum perubahan 69.75% menjadi 97.85%  terjadi peningkatan untuk layanan 3G pada area tersebut dengan melakukan perubahan untuk BTS TB_Purnama2 secara azimuth tilt. Proses perubahan selanjutnya dilakukan pada BTS Perum Perdana untuk menanggulangi keluhan pada jaringan 4G, pada BTS tersebut dilakukan perubahan dengan metode electrical tilt yang merubah fasa sinyal antena sektor 2 untuk layanan 4G dengan kondisi sebelum perubahan berada di 10o menjadi 5o, selanjutnya dalam penelitian ini layanan jaringan GSM pada area tersebut kembali diuji melalui drive test dengan merujuk parameter KPI yang digunakan PT. Telkomsel Pontianak untuk layanan 4G yaitu RSRP dan SNR yang menghasilkan peningkatan layanan jaringan GSM pada area yang dikeluhkan dengan kenaikan untuk RSRP dengan kualitas baik 12.93% dengan selebihnya didominasi kualitas cukup baik dan tidak ada kualitas buruk pada area tersebut, sedangkan parameter SNR mengalami kenaikan 9.42% untuk kualitas cukup baik dengan selebihnya didominasi dengan kualitas buruk dan 0.00%  kualitas baik untuk parameter SNR pada penelitian ini dengan kesimpulan terjadi peningkatan untuk layanan 4G pada area tersebut dengan melakukan perubahan untuk BTS Perum Perdana secara electrical tilt. Kata kunci : Physical Tunning, Antenna sectoral
EVALUASI PEMBANGKIT LISTRIK TENAGA MIKRO HIDRO (PLTMH) KAPASITAS 40 kVA DESA RIRANG JATI KECAMATAN NANGA TAMAN KABUPATEN SEKADAU Asyad Nugroho .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 5, No 1: Januari 2017
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v5i1.18033

Abstract

Abstrak -         Pembangkit Listrik Tenaga Mikro Hidro (PLTMH) Desa Rirang jati Kecamatan Nanga Taman Kabupaten Sekadau terletak di daerah  Dusun  Nuak  di  Desa  Rirang Jati Kecamatan Nanga Taman Kabupaten  Sekadau.  PLTMH langsung dikelola oleh masyarakat setempat dan PLTMH ini beroperasi memanfaatkan   aliran   sungai   nuak yang  merupakan  sungai  kecil  di daerah tersebut.   Dalam penelitian ini menggunakan metode apung yang digunakan   untuk   mengambil   data debit air. Pengambilan data dilakukan dalam  waktu  2  hari  berturut  -  turut dari jam 07.00 – 17.00 WIB dan dilakukan pada musim hujan.   Hasil evaluasi menunjukan bak penenang tidak mempunyai saluran pelimpah   (spillway) dan   pada   pipa pesat tidak memiliki pipa nafas pada ujungnya seperti yang sudah ditetapkan pada Peraturan Menteri ESDM Nomor 08 Tahun 2011. Hasil perhitungan potensi daya yang dapat dibangkitkan adalah 54,48 kW dengan debit air 2,04 m3/s dan tinggi efektif 4,126 m. Sedangkan daya maksimal yang dimanfaatkan masyarakat hanya 8,244 kw dan daya yang tertera pada generator 35 kw. Perbandingannya adalah 15%, itu dikarenakan mayoritas masyarakat disana mempunyai tingkat ekonomi rendah dan tidak adanya industri – industri kecil yang memerlukan listrik. Namun, dilihat dari kondisi masyarakat yang menggunakan   listrik   dari   PLTMH yang  menggunakan  generator  ini sudah   tepat,   namun   masih   banyak daya yang tidak digunakan karena beban maksimal yang digunakan masyarakat 8,1524 kW.   Untuk frekuensi yaitu 50 Hz, namun range yang ada pada kontrol panel selalu tidak konstan, itu karena sistem PLTMH tergantung pemakaian beban yang digunakan sesuai dengan kebutuhan mereka. Sistem kontrol menggunakan sistem sederhana yaitu dengan menghidupkan lampu berkapasitas 4200 watt pada malam hari mulai pukul 22.00 wib sampai pukul 05.00 WIB. Tetap saja belum efektif, hanya saja karena harga untuk sistem kontrol beban elektronik cukup mahal   kurang   lebih   sama   dengan harga generator atau turbin, penggunaan   sistem   kontrol   manual dengan menggunakan lampu menjadi langkah yang dilakukan masyarakat.   Kata kunci - PLTMH,     generator,     dan

Page 1 of 3 | Total Record : 24