cover
Contact Name
Ridwan
Contact Email
ridwan@eng.unri.ac.id
Phone
+6285271704005
Journal Mail Official
jictech@ejournal.unri.ac.id
Editorial Address
Journal of Infrastructure and Construction Technology Dept. of Civil Engineering, Faculty of Engineering, Universitas Riau Jl. Pekanbaru-Bangkinang KM 12.5 Pekanbaru, 28293
Location
Kota pekanbaru,
Riau
INDONESIA
Journal of Infrastructure and Construction Technology
Published by Universitas Riau
ISSN : 30248523     EISSN : 29878934     DOI : https://doi.org/10.56208/jictech
Core Subject : Engineering,
Journal of Infrastructure and Construction Technology (Jictech) is a peer-reviewed academic journal that publishes novel concepts, theories, methodologies, and procedures in science and engineering. The following themes will be covered by the journal, but are not limited to: Structural engineering, Construction management, Environmental engineering, Water resources and hydrology engineering, Geotechnical engineering, Coastal and harbour engineering, Surveying and Geospatial engineering, Transportation engineering, and Construction materials.
Articles 31 Documents
Tinjauan Kritis Metode Perkuatan Struktur Kolom Beton Bertulang Terkorosi Menggunakan Teknik Jacketing Sugito Sugito
Journal of Infrastructure and Construction Technology Vol. 3 No. 2 (2025): July 2025
Publisher : Dept. of Civil Engineering Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56208/jictech.3.2.38-49

Abstract

Corrosion of reinforcing steel reduces bar area and bond, while corrosion-product expansion can crack and detach the concrete cover. This review critically examines RC jacketing, steel jacketing, FRP wrapping, and prefabricated composite jackets for reinforced concrete columns. CFRP tests on uncorroded square columns reported capacity gains of 14.29–23.15% without fan anchors and 36.6–38.5% with anchors, relative to unconfined controls. Corrugated steel jackets increased axial capacity by 34.6–67.3% in ten mechanically pre-damaged short columns. For prefabricated jackets, tests with simulated reinforcement loss reported recovered capacities of 99% and 95% of the undamaged reference at 25% and 50% simulated loss; simulated cover damage of 50% and 100% produced recovery values of 95% and 82%. A local RC-jacketing case study showed D/C ratios decreasing from 1.212–3.495 to 0.532–0.639 in five selected columns; it was not a corrosion test. These results are not directly comparable because specimen geometry and damage procedures differed. Prefabricated composite jackets offer the most direct evidence among the reviewed studies for simulated reinforcement loss, but field validation under actual corrosion and tropical exposure remains necessary.

Page 4 of 4 | Total Record : 31