cover
Contact Name
Dina Mariani
Contact Email
dinamariani@unimus.ac.id
Phone
+6285299398663
Journal Mail Official
mediaelektrika@unimus.ac.id
Editorial Address
Universitas Muhammadiyah Semarang FT-FMIPA Building, 7nd Floor. Department of Electrical Engineering Jl. Kedungmundu Raya No. 18, Kota Semarang, Prov. Jawa Tengah, Indonesia 50273 Phone: 085299398663 Email: mediaelektrika@unimus.ac.id
Location
Kota semarang,
Jawa tengah
INDONESIA
MEDIA ELEKTRIKA
ISSN : 19797451     EISSN : 2579972X     DOI : 10.26714/me.14.2.2021.62-75
Media Elektrika is an electrical engineering journal that gives concerns on sciences related to electrical engineering. It includes the following fields: Electrical power engineering Electronics Telecommunication Control Informatics and computer technology
Articles 5 Documents
Search results for , issue "Vol 3, No 2 (2010): Electrical Engineering" : 5 Documents clear
PENGEMBANGAN KERANGKA KERJA MIGRASI SISTEM PAPERLESS OFFICE Bambang Supradono
MEDIA ELEKTRIKA Vol 3, No 2 (2010): Electrical Engineering
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3529.353 KB) | DOI: 10.26714/me.3.2.2010.%p

Abstract

Occurrences Paperless Office in line with advances in information technologi. Technology allows people to obtain alternative information in the processing and reading documents by reducing the use of paper that is currently called paperless office system. This study attempts to explore the framework of the migration processing and reading documents that use paper for the use of information technology. The initial step to identify business processes that use paper. Design information technology infrastructure both in terms of hardware architecture and software. and then followed by a strategy of migration to a paperless office system (PLO) So the conversion technology acquired paper documents into digital documents and transform business processes that use a lot of paper in business processes using sofware applications.Keywords: paperless office, digital documents, sofiware applications.
KEGAGALAN ISOLASI MINYAK TRAFO Dedi Nugroho
MEDIA ELEKTRIKA Vol 3, No 2 (2010): Electrical Engineering
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1705.477 KB) | DOI: 10.26714/me.3.2.2010.%p

Abstract

Insulation of transformer oil has a role as an insulating material of voltage equipment in electrical equipments, but has other uses such as cooling media or extinguish the arc. Purity insulating oil will determine the strength of the dielectric material. On the condition of purity used oil will be contaminated by other subtances mixed in the oil, the result of oil will become impure and degraded dielectric strength that will ultimately reduce the level of insulation failure, isolation and purification of used oil (no pure oil) was able to significantly increase the insulation failure rate of new oil approach.
Potensi Clean Development Mechanism pada Pembangkit Mikrohidro 120 KW - Gunawan; Didiek Eko Budi Santoso; M. Subchan
MEDIA ELEKTRIKA Vol 3, No 2 (2010): Electrical Engineering
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1389.873 KB) | DOI: 10.26714/me.3.2.2010.%p

Abstract

Polential of Micro Hydro Power in remote areas is the most realistic as the primary energy for electricity generation. Potential energy become a growing alternative for the region to diversify its electricity supply. The issue of global warming that encourages the use of renewable energy in an effort to prevent damage to the natural speed of following up a global agreement under the Kyoto Protocal. One program in the reduction of exhaust emissions is the Clean Development Mechanism (CDM). Through this concept all the activities of energy usage can be measured and calculated potential relation with the exhaust emissions.CDM potential measurement begins by defining the instrument to be used. MHP is the power output is a fixed value that is used as a reference that will measure the impact if generated by fossil energy utilization. This step is an approach that shows how the potential for greenhouse gas emissions that can be prevented if the electrical power needs supplied by renewable energy-based generation.The sample of study is MHP Cinta Mekar in Subang district indicates that this location was proposed as a viable small-scale projects under the CDM. MHP is able to produce electrical energy of 120 KW. CDm potential is calculated are the reduction of fossil energy consumption of 1.5 tons per day. In addition to equality of use of fossil fuels for electrical potential energy also has the potential to reduce environmental pollution by 1474.2 tons / year of CO2.Keyword : CDM, MHP, Energy, Pollution
EFEKTIFITAS PEMASANGAN KAPASITOR SEBAGAI METODE ALTERNATIF PENGHEMAT ENERGI LISTRIK M. Tony Prasetyo; Luqman Assaffat
MEDIA ELEKTRIKA Vol 3, No 2 (2010): Electrical Engineering
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1612.936 KB) | DOI: 10.26714/me.3.2.2010.%p

Abstract

Efficiency needs to be done by PLN as a provider of electrical energy and of course also by the user community as consumers of electrical energy. One of the efficiency measures to conserve energy use in the community is the use of energy-efficient electical appliances (energy saver) areused both in business, commercial or industrial or domestic sector. Energy-efficient appliances are now widely sold in the wider community as they seek to offset the cost of electrical energy consumption. Equipment generally contains capacitor banks or elco (electrolyt condensator) whichcan reduce electric currents, but no significant effect on consumer savings account payments.The Study that's obout improving the power factor has been more on the side of the electricity supplier. both in transmission and distribution. On the load side (electricity consumers), the measurement of power factor and load balancing only on the main panel or distribution ponel.so that the measured accumulated loads of different types of loads.So far research on increasing the load power factor only produces the resulting level of power efficiency and whether this level can still be expected usefulness in relieving the financial burden of the electricity customer bills or not. So we need to do a study b determine the efficiencyof the dominant power generated by the load in conjunction with electric power triangle.Keywords : Power Capacitor, Load, efficiency of electric power
Perancangan Sistem Automatic Cruise Control (ACC) Menggunakan Metode Depes (Development Process of Embedded System) Dengan Simulasi Java M. Iman Santoso
MEDIA ELEKTRIKA Vol 3, No 2 (2010): Electrical Engineering
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2332.325 KB) | DOI: 10.26714/me.3.2.2010.%p

Abstract

Design is an important parl of a system building. Design of the system could be existing system development or create from the scratch. This paper studies the system development in case of Automatic Cruice Control (ACC). DePES (Development Process of Embedded System) is used to design such system. This Process focused on embedded sofware components, problem analysis, specifications, architechture and test. In order to illustrate and test the proposed sytem, Java simulation is provided.

Page 1 of 1 | Total Record : 5