Rancang Bangun Prototype Tap Changer Otomatis Berbasis IoT Menggunakan Transformator Satu Fasa Skala Laboratorium Japriansyah, Dimas Aryo; Koerniawan, Tony; Rabbani, Arya Rambu; Fajar, Artyastu; Arasyid, Tsabit
Journal of Authentic Research Vol. 5 No. 2 (2026): May
Publisher : LITPAM

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36312/y7hakf06

Abstract

Voltage fluctuations in distribution systems may cause service voltages to exceed standard limits, requiring transformer tap regulation mechanisms to maintain voltage stability. However, testing tap changers on full-scale distribution transformers involves safety risks, high costs, and limited flexibility for laboratory modifications. This study aims to design and evaluate an Internet of Things (IoT)-based tap changer prototype using a single-phase laboratory-scale transformer. The research employed an experimental design-and-development approach consisting of hardware design, software development, prototype assembly, and laboratory testing. The system comprises a single-phase transformer with five secondary-side tap positions, an ESP32 microcontroller, a PZEM-004T v3.0 sensor, a five-channel active-LOW relay module, and the Blynk platform for remote monitoring and control. Output voltage was measured every three seconds and used as the basis for tap selection within a voltage range of 198 V to 231 V. Testing was conducted using three types of loads: a 60 W incandescent lamp, a rheostat, and a combined incandescent lamp-rheostat load. The results show that Tap 2 to Tap 5 maintained output voltages within the acceptable range, while Tap 1 remained below the minimum standard limit under all load conditions. The maximum positive voltage deviation was +2.27% at Tap 5 under the incandescent lamp load, whereas the maximum negative deviation was -11.59% at Tap 1 under the combined load condition. The PZEM-004T sensor achieved an average relative error of 0.35% compared with a clamp power meter for voltage measurements. These findings indicate the preliminary feasibility of the proposed prototype as an IoT-based laboratory simulation and educational platform for transformer tap regulation, particularly under resistive loads and limited testing conditions. Further studies are required to evaluate system performance under inductive loads, dynamic voltage fluctuation scenarios, and long-term automatic control operation.
Design and Construction of an IoT-Based Three-Phase Electric Motor Monitoring and Protection Device Rabbani, Arya Rambu; Diantari, Retno Aita
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.16977

Abstract

Three-phase induction motors are widely used in industry as the main drive for pumps, compressors, and conveyors, yet they remain vulnerable to overcurrent, voltage unbalance, and overheating that can shorten their service life. Conventional protection devices such as thermal overload relays and circuit breakers operate locally and do not provide real-time condition information to operators. This study designs and builds an Internet of Things (IoT)-based monitoring and protection device for three-phase electric motors that can observe motor conditions in real time and respond automatically to disturbances. The hardware uses an ESP32 S3 microcontroller, three PZEM-004T sensors to measure voltage, current, power, frequency and power factor, and three MLX90614 non-contact infrared sensors to measure motor temperature. Protection is executed through a solid-state relay coupled to a contactor, while monitoring data are displayed locally on a 3.5-inch TFT screen and remotely through the Blynk IoT platform and Telegram notifications. Testing shows that the prototype trips automatically when the current exceeds the setting value and when the voltage deviation between phases exceeds 2%, with an average trip response time of 354.4 ms, while normal operating conditions do not trigger false trips. Comparison against a standard measuring instrument shows a maximum measurement error of 1.67%. These results indicate that the proposed system is accurate, responsive, and suitable for improving the safety and reliability of three-phase motor operation.