Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisis Pengaruh Variasi Bentuk Shear Wall terhadap Perilaku Struktur Gedung Bertingkat Pramesta Armanisag Pangestuti; Agustinus Sungsang Nana Patria; Adam Miskah
Konstruksi: Publikasi Ilmu Teknik, Perencanaan Tata Ruang dan Teknik Sipil Vol. 4 No. 3 (2026): Juli: Konstruksi: Publikasi Ilmu Teknik, Perencanaan Tata Ruang dan Teknik Sipi
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/konstruksi.v4i3.1519

Abstract

The development of multistory buildings in earthquake-prone regions requires structural systems capable of limiting lateral displacement and maintaining stability. Shear walls are commonly used to improve lateral stiffness, but their effectiveness depends on cross-sectional shape. This study evaluates the effect of shear wall shape variations on an eight-story reinforced concrete office building and identifies the most effective configuration based on natural period, interstory drift, base shear, internal forces, and structural safety. The building measures 18 × 30 m, has a height of 32 m, and was modeled three-dimensionally using ETABS. Five models were compared: a structure without shear walls and structures with C-shaped, IWF-shaped, I-shaped, and L-shaped shear walls. All models used identical geometry, materials, loading, and seismic parameters in accordance with SNI 1726:2019 and SNI 2847:2019. The results show that Model 1 has the longest period, Model 2 produces the largest drift in the X direction, and Model 3 provides the smallest drift but experiences overstress in the coupling beam. Model 5 causes high internal-force concentration in the beams. Model 4, with an I-shaped shear wall, demonstrates the most balanced performance because it satisfies the allowable drift limit, provides uniform stiffness, controls internal forces, and shows no overstressed elements.
Seismic Response Comparison of Tidar Regional Hospital Using Equivalent Static, Response Spectrum, and Time-History Methods Agustinus Sungsang Nana Patria; Pramesta Armanisag Pangestuti; Rahma Amalia Sinatria
Jurnal Civil Engineering Study Vol. 6 No. 02 (2026): Jurnal Civil Engineering Study
Publisher : Civil Engineering of Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Earthquake analysis methods affect structural response and member demands. This study compares equivalent static, response spectrum, and time-history analyses of the Aster Inpatient Building at Tidar Regional Public Hospital in Magelang, a six-story reinforced-concrete structure on site class SD. The ETABS model uses a special moment-resisting frame system. Time-history analyses use the Sanriku Iwate 2011, Fukushima Chiba 2011, and Cook Strait 2013 records after spectral matching. The comparison parameters include base shear, modal characteristics, lateral displacement, stability coefficients, and moments and shear forces in selected members. The largest X-direction base shear occurred under the Sanriku record at 6,259.332 kN, while the largest Y-direction value occurred under response spectrum analysis at 5,771.447 kN. The Fukushima and Cook Strait responses were approximately 18–19% of the equivalent static values, indicating that scaling equivalence should be checked. Sanriku produced beam and column moments of 1,267.019 kN·m and 2,668.113 kN·m, respectively. The equivalent static and response spectrum methods produced larger reported lateral displacements than the three time-history records. The findings indicate that global and local responses should be considered together. Final assessment of interstory drift and stability requires consistent displacement definitions, spectrum parameters, units, and scale factors.