Evy Diah Woelansari
Teknologi Laboratorium Medis, Politeknik Kesehatan Kementrian Kesehatan Surabaya

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

SCREENING PASIEN SUSPEK DEMAM TIFOID DENGAN WIDAL TES DAN RAPID TEST IgM ANTI-SALMONELLA DAN RASIO MONOSIT–LIMFOSIT (MLR) Marshanda Pratiwi Miftahurrahma; Evy Diah Woelansari; Museyaroh Museyaroh; Dwi Krihariyani
HEALTHY : Jurnal Inovasi Riset Ilmu Kesehatan Vol. 5 No. 4 (2026)
Publisher : Pusat Pengembangan Pendidikan dan Penelitian Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51878/healthy.v5i4.14375

Abstract

Typhoid fever is an infectious disease caused by Salmonella typhi and remains a major public health problem in Indonesia. The diagnosis of typhoid fever is generally confirmed through serological tests such as the Widal test and the anti-Salmonella IgM rapid test. Both tests are commonly used, but they have limitations in sensitivity and specificity. The monocyte-lymphocyte ratio (MLR) is a hematological parameter that has the potential to serve as a supportive indicator because it reflects both innate and adaptive immune responses. The objective of this study was to analyze the relationship between the monocyte-lymphocyte ratio (MLR) and the Widal test and anti-Salmonella IgM rapid test in patients with suspected typhoid fever. This study was conducted using an observational analytical method with a cross-sectional design. The study sample consisted of 29 patients with suspected typhoid fever at the Klinik Ultra Medica in Tulungagung, selected through purposive sampling. The results showed that MLR values fell into the low category in 79.3% of cases, moderate in 17.2%, and high in 3.4%. The anti-Salmonella IgM rapid test results showed 37.9% positive and 62.1% negative. The Widal test results were dominated by a titer of 1/80 (79.3%) and a titer of 1/160 (13.8%). Spearman's rank correlation test yielded r = 0.200 (p = 0.298) between MLR and anti-Salmonella IgM rapid test, and r = -0.133 (p = 0.490) between MLR and Widal test. In conclusion, there is no significant association between the monocyte-to-lymphocyte ratio (MLR) and the results of either the Widal test or the anti-Salmonella IgM rapid test in patients with suspected typhoid fever (p > 0.05). ABSTRAK Demam tifoid merupakan penyakit infeksi yang disebabkan oleh bakteri Salmonella typhi dan hingga saat ini masih menjadi masalah kesehatan masyarakat di Indonesia. Penegakan diagnosis demam tifoid umumnya dilakukan melalui pemeriksaan serologi seperti tes Widal dan rapid test IgM anti-Salmonella. Keduanya masih sering digunakan, namun memiliki keterbatasan sensitivitas dan spesifisitas. Rasio monosit-limfosit (Monocyte-Lymphocyte Ratio / MLR) merupakan parameter hematologi yang berpotensi menjadi indikator pendukung diagnosis demam tifoid karena mencerminkan respons imun bawaan dan adaptif. Penelitian ini bertujuan untuk menganalisis hubungan rasio monosit-limfosit (MLR) dengan tes Widal dan rapid test IgM anti-Salmonella pada pasien suspek demam tifoid. Penelitian ini menggunakan metode observasional analitik dengan desain cross-sectional. Sampel penelitian berjumlah 29 pasien suspek demam tifoid di Klinik Ultra Medica Tulungagung yang dipilih secara purposive sampling. Hasil penelitian menunjukkan nilai MLR berada pada kategori rendah 79,3%, sedang 17,2%, dan tinggi 3,4%. Hasil rapid test IgM anti-Salmonella menunjukkan 37,9% positif dan 62,1% negatif. Hasil tes Widal didominasi oleh titer 1/80 sebesar 79,3% dan titer 1/160 sebesar 13,8%. Hasil uji korelasi Spearman Rank antara MLR dengan rapid test IgM anti-Salmonella menghasilkan  ( ), sedangkan antara MLR dengan tes Widal menghasilkan  ( ). Dengan demikian, tidak terdapat hubungan yang signifikan antara rasio monosit-limfosit (MLR) dengan hasil tes Widal maupun rapid test IgM anti-Salmonella pada pasien suspek demam tifoid ( ).    
PERBANDINGAN KADAR HIGH SENSITIVITY C-REACTIVE PROTEIN (hs-CRP) METODE Fluoroescence Immunoassay (FIA) ANTARA SAMPEL SERUM DAN PLASMA EDTA PADA PENDERITA DIABETES MELITUS Kanayu Aulia Masardi; Suhariyadi Suhariyadi; Wisnu Istanto; Evy Diah Woelansari
HEALTHY : Jurnal Inovasi Riset Ilmu Kesehatan Vol. 5 No. 4 (2026)
Publisher : Pusat Pengembangan Pendidikan dan Penelitian Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51878/healthy.v5i4.13729

Abstract

Diabetes mellitus is a chronic metabolic disorder associated with increased inflammatory activity and contributes to the development of cardiovascular complications. High-sensitivity C-reactive protein (hs-CRP) serves as an inflammatory marker to evaluate low-grade systemic inflammation. Accurate specimen selection is crucial for analytical validity. This study aims to compare hs-CRP levels measured by Fluorescence Immunoassay (FIA) between serum and EDTA plasma specimens in patients with diabetes mellitus. An observational comparative study with a cross-sectional design was conducted using 20 paired serum and EDTA plasma samples from diabetes mellitus patients at Haji General Hospital, East Java Province, in March 2026. hs-CRP levels were measured using the FIA method. The mean hs-CRP concentration in serum was  ( ) and in EDTA plasma was  ( ). The Wilcoxon Signed Rank Test yielded a  of 0.463 ( ), indicating no statistically significant difference between serum and EDTA plasma hs-CRP levels. In conclusion, serum and EDTA plasma demonstrate analytical equivalence for hs-CRP measurement using the FIA method, allowing EDTA plasma to serve as a valid alternative specimen in routine laboratory practice. ABSTRAK Diabetes melitus merupakan gangguan metabolisme kronis yang berkaitan dengan peningkatan aktivitas inflamasi dan berkontribusi terhadap perkembangan komplikasi kardiovaskular. High-sensitivity C-reactive protein (hs-CRP) digunakan sebagai penanda inflamasi untuk menganalisis proses peradangan kronis tingkat rendah (low-grade inflammation). Ketepatan pemilihan spesimen laboratorium sangat memengaruhi validitas analitik. Penelitian ini bertujuan untuk membandingkan kadar hs-CRP metode Fluorescence Immunoassay (FIA) antara spesimen serum dan plasma EDTA pada penderita diabetes melitus. Penelitian observasional komparatif dengan desain cross-sectional ini dilakukan terhadap 20 pasang spesimen serum dan plasma EDTA dari pasien diabetes melitus di RSUD Haji Provinsi Jawa Timur pada Maret 2026. Kadar hs-CRP diukur menggunakan metode FIA. Hasil penelitian menunjukkan rerata kadar hs-CRP serum sebesar  ( ) dan plasma EDTA sebesar  ( ). Hasil uji Wilcoxon Signed Rank Test menghasilkan nilai  ( ), yang menunjukkan tidak terdapat perbedaan yang bermakna secara statistik antara kadar hs-CRP pada spesimen serum dan plasma EDTA. Kesimpulannya, serum dan plasma EDTA memiliki kesepadanan analitik dalam pemeriksaan hs-CRP metode FIA, sehingga plasma EDTA dapat digunakan sebagai spesimen alternatif yang valid dalam kondisi darurat laboratorium.