Ahmad, Norsham
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Changes in Contrast Sensitivity in Young Adults with Diabetes Abd Rahman, Aziimah A; Badarudin, Noor E; Che Azemin, Mohd Z; Ahmad, Norsham; Arifin, Azrin E
Makara Journal of Health Research Vol. 22, No. 1
Publisher : UI Scholars Hub

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Background: This study compared contrast sensitivity and visual acuity of young adults with diabetes to that of controls and attempted to identify predictors of dry eye symptoms in patients with diabetes. Methods: This cross-sectional study, which included 37 patients with diabetes and 37 age-matched controls, was conducted in the Optometry Clinic of Kulliyyah Allied Health Science. All participants were aged between 19 and 39 years. Inclusion criteria were a diagnosis of diabetes without any evidence of ocular disease, abnormalities in colour vision or media opacity. Results: The contrast sensitivity significantly differed between patients and controls (p = 0.045). A multiple regression analysis showed that contrast sensitivity was a significant predictor of ocular symptoms in patients with diabetes, and this was statistically significant (p = 0.002). Conclusions: Contrast sensitivity may be affected during early ocular changes among young adults with diabetes. It may also predict the occurrence of dry eye symptoms in such patients.
Corneal Curvature Measurements Utilizing a New Swept-source Optical Coherence Tomography Tomey OA-2000® and Comparison With IOL Master® 500 in Pterygium Patients Hilmi, Mohd Radzi; Mohd Kamal, Khairidzan; Che Azemin, Mohd Zulfaezal; Ithnin, Mohd Hafidz; Md Mustafa, Md Muziman Syah; Yusof@Alias, Firdaus; Ahmad, Norsham
Sains Medika: Jurnal Kedokteran dan Kesehatan Vol 9, No 1 (2018): June 2018
Publisher : Faculty of Medicine, Universitas Islam Sultan Agung (UNISSULA), Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (742.707 KB) | DOI: 10.30659/sainsmed.v9i1.2918

Abstract

Introduction: Corneal curvature (CC) is an important anterior segment parameter. This study compared CC measurements conducted with two optical devices in pterygium eyes.Methods: Sixty pterygium eyes of 30 patients were enrolled in this study. CC was measured three times with the optical biometer and topography-keratometer Tomey OA-2000 (Tomey Corporation, Nagoya, Japan), then with partial optical coherence interferometry (PCI) IOL Master 500 (Carl Zeiss Meditec, Dublin, CA) and data were statistically analysed.Results: The measurements revealed in a mean CC of 43.86 ± 1.57 D with Tomey OA-2000 and 43.84 ± 1.55 D with IOL Master. Distribution of data is normal, and no significance difference in CC values was detected (P = 0.952) between the two devices. Correlation between CC measurements was highly significant (r = 0. 99; P < 0.0001). The mean difference of CC values between devices was 0.017 D and 95% limit of agreement was -0.088 to 0.12. Duration taken for measurements with the standard biometer IOL Master was longer (55.17 ± 2.24 seconds) than with Tomey OA-2000 (39.88 ± 2.38 seconds) in automatic mode. Duration of manual measurement with Tomey OA-2000 in manual mode was shorter (28.57 ± 2.71 seconds).Conclusion: In pterygium eyes, CC measured with Tomey OA-2000 and IOL Master showed similar values, and high correlation was observed between these two devices. This shows that both devices can be used interchangeably. Tomey OA-2000 is better in terms of faster to operate and has its own topography systems.