Mukhnizar Mukhnizar
Universitas Ekasakti, Padang, Indonesia

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Analysis of the Causes of Damage to the Poly Aluminium Chloride (PAC) Dosing Pump for Maintenance Actions at the Palukahan Water Treatment Plant (IPA), Perumda Air Minum Kota Padang Hal Haviz; Risal Abu; Mukhnizar Mukhnizar
The Future of Education Journal Vol 5 No 3 (2026)
Publisher : Lembaga Penerbitan dan Publikasi Ilmiah Yayasan Pendidikan Tumpuan Bangsa

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The increasing demand for clean water in Padang City requires optimal performance of water treatment plants (WTPs), including the Palukahan Water Treatment Plant. In the water treatment process, Poly Aluminium Chloride (PAC) solution is used as a coagulant and injected through a dosing pump. The reliability of the dosing pump is crucial for ensuring that the quality of treated water complies with the standards stipulated in Indonesian Ministry of Health Regulation No. 2 of 2023. However, failures in the dosing pump can disrupt the coagulation process and reduce water treatment efficiency. This study aims to analyze the causes of dosing pump failures and provide recommendations for appropriate maintenance actions. The recommended maintenance strategies include periodic preventive maintenance, corrective maintenance in response to operational anomalies, and regular evaluation of pump performance parameters. This study is expected to serve as a technical reference for Perumda Air Minum Kota Padang in improving the reliability of the dosing system and maintaining the quality of clean water services for the community.
Design of a Centrifugal Pump with a Capacity of 50 Liters per Second, a Head of 35 m, and a Rotational Speed of 1,550 rpm Apri Muhtadi; Mukhnizar Mukhnizar; Risal Abu
The Future of Education Journal Vol 5 No 3 (2026)
Publisher : Lembaga Penerbitan dan Publikasi Ilmiah Yayasan Pendidikan Tumpuan Bangsa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61445/tofedu.v5i3.2285

Abstract

A pump is a type of fluid machinery used to transfer fluids from one location to a higher elevation or to a location with higher pressure. It is an energy-conversion machine that converts mechanical energy in the form of rotational motion into fluid energy in the form of pressure and velocity. Understanding pump characteristics is essential for selecting a pump that meets the required operating conditions, particularly in terms of flow capacity, head, and operational efficiency. The centrifugal pump in this study was designed with a flow capacity of 50 liters per second, a head of 35 m, and a rotational speed of 1,550 rpm. Based on the design results, the pump to be redesigned is a single-stage centrifugal pump equipped with an open radial impeller, a pump head of 50 m, and a pump power requirement of 75 kW. The design process involved comprehensive calculations, including pump head, number of stages, impeller dimensions, supporting components, efficiency, and pump characteristics. The pump is driven by an AC electric motor with a voltage of 380 V and a rotational speed/frequency of approximately 3,000 rpm/50 Hz. Thus, the production unit is expected to operate continuously, enabling the treated clean water to be distributed to the community in accordance with the specifications and performance requirements of the pump.
Optimization of Screw Conveyor Maintenance Using the Total Productive Maintenance (TPM) Method at PT Semen Padang Irsyad Wahyudi; Mukhnizar Mukhnizar; Zulkarnain Zulkarnain
The Future of Education Journal Vol 5 No 3 (2026): 2
Publisher : Lembaga Penerbitan dan Publikasi Ilmiah Yayasan Pendidikan Tumpuan Bangsa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61445/8m46ye85

Abstract

Maintenance of the screw conveyor at the Packing Plant of PT Semen Padang is examined through component condition, preventive maintenance practices, and the implementation of Total Productive Maintenance (TPM) as a basis for maintenance optimization. Data were collected through component observation, interviews with operators and maintenance technicians, and measurements of screw conveyor speed and electric motor current before and after preventive maintenance. The observed components included the screw, housing, shaft, bearing, gearbox, and electric motor. The observation results showed that the main screw conveyor components were generally in good condition, although cement material deposits were found on the screw and housing. The measurement results showed that the screw conveyor speed increased from 69.2 rpm to 70.8 rpm, while the electric motor current decreased from 15.6 A to 14.2 A after cleaning. These changes indicate an improvement in operating conditions following preventive maintenance. TPM implementation was carried out through planned maintenance activities and operator involvement in inspection and cleaning. However, inspection checklists, maintenance documentation, and periodic evaluation still need to be improved. Maintenance optimization is proposed through the preparation of inspection checklists, improved maintenance documentation, and periodic maintenance evaluation to maintain screw conveyor reliability.