Iis Haryati
Pusat Teknologi Bahan Bakar Nuklir – BATAN

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

PENENTUAN UMUR YELLOW CAKE SECARA RADIOKRONOMETRI Erlina Noerpitasari; Syamsul Fatimah; Iis Haryati; Yanlinastuti Yanlinastuti; Jan Setiawan; Boybul Boybul; Arif Nugroho
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 26 No. 2 (2020): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2020.26.2.6057

Abstract

YELLOW CAKE AGE DETERMINATION BY RADIOCHRONOMETRY. Radiochronometric dating of yellow cake has been carried out. The aim of this study was to obtain data on the age of yellow cake for compiling a database for nuclear forensics library. The radiochronometer used was228Th/232Th. 232Th is thorium which naturally co-exists in yellow cake and will reach a decay equilibrium to 228Th. In the yellow cake production process, however, the equilibrium is disturbed so that the "time" will be zeroed again. The test samples were yellow cake from Cogema, from PTBGN mining in Kalan, and by-products from Petrokimia Gresik. The steps of processes include dissolving the sample, separating thorium from uranium by cation exchange chromatography using dowex 50W-X8 resin, electrodeposition of thorium and isotopes analysis using an alpha spectrometer. Age determination was performed by calculating the 228Th/232Th activity ratio and decay formula iteration. Based on the analysis of the 228Th and 232Th isotopes using an alpha spectrometer and the results of age calculations, the age of Cogema yellow cake was not able to be determined because it does not contain 232Th. The age of Petrokimia Gresik yellow cake is 9.90 years with a bias of 20.35 years and the age of PTBGN yellow cake is 12.85 years with a bias of more than 20.15 years when compared to the known estimated production time. The bias obtained is higher when compared to the results determined by previous researchers by the same method,i.e., a bias of less than 10 years.
ANALISIS ISOTOP 137Cs DALAM PEB U3Si2/Al DENSITAS 4,8 gU/cm3 PASCA IRADIASI DENGAN METODE PENGENDAPAN CHLOROPLATINATE DAN KOLOM PENUKAR KATION RESIN DOWEX Arif Nugroho; Boybul Boybul; Sutri Indaryati; Iis Haryati; Rosika Kriswarini; Erlina Noerpitasari
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 26 No. 3 (2020): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2020.26.3.6055

Abstract

SEPARATION OF CESIUM IN IRRADIATED U3Si2/Al FUEL PLATE WITH A DENSITY OF 4.8 gU/cm3 USING CHLOROPLATINATE DEPOSITION METHOD AND DOWEX RESIN CATION EXCHANGE COLUMN. Dissolution of the U3Si2/Al plate was carried out in hot cell 109 using 6 M HCl and 6 M HNO3 solutions. The separation of cesium and uranium in uranyl nitrate solution was carried out using chloroplatinate deposition method and a cation exchange column. In the chloroplatinate deposition, the process of removing elements that will interfere with the deposition process was performed first, then the separation of heavy elements such as uranium or plutonium was carried out by depositing the 137Cs in the form of Cs2PtCl6. The isotope content of 137Cs in the Cs2PtCl6 deposition was measured with a γ spectrometer. In the Dowex resin cation exchange column method, the uranyl nitrate solution was pipetted 150 μL to be added to 2 mL of aquadest. To this solution was then added 20 μL of Cs carrier and 1 mL of 12 M HCl. The mixture of the solution was used as feed and put into the anion exchange column containing R-Cl resin. The effluent exiting the anion exchange column was fed into the cation exchange column containing R- NH4+ resin. The 137Cs isotope bound to R NH4+ resin in the column was then eluted using 1 M HCI. The effluent was compressed until a volume of ± 2 mL was obtained. The isotope content of 137Cs in U3Si2 / Al plate obtained as a result of separation using the chloroplatinate method for middle slices coded M has an average of 0.000557 g/g fuel and 0.000652 g/g fuel for the bottom slices coded B, while the Dowex resin cation exchange column method gave an average of 0.000747 g/g fuel for middle slices coded M, and 0.000934 g/g fuel for bottom slices coded B. The recovery of 137Cs separation by the anion exchange column method was greater than that of the Cs2PtCl6 deposition method.