Heatsink geometry effect on the thermal performance of a waste heat thermoelectric generator: experimental and CFD analysis Sugiyanto Sugiyanto; Nyayu Aisyah; Yosephus Ardean Kurnianto Prayitno; Irfan Bahiuddin
Jurnal Polimesin Vol 24, No 5 (2026): October
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/jpl.v24i5.8881

Abstract

Thermoelectric Generators (TEGs) offer a promising approach for recovering waste heat from diesel exhaust. However, their performance strongly depends on maintaining a sufficient temperature difference between the hot and cold sides of the module, making the design of the cold-side cooling system particularly important. This study investigates the effect of heatsink geometry on the thermal performance of a waste-heat TEG system integrated with a diesel generator. Three heatsink configurations, designated as P90; P120, and P150 are examined at an engine speed of 780 RPM and 1500 RPM. This analysis combines Experimentation and Computational Fluid Dynamics (CFD). Evaluated numerical results include temperature contours, thermal gradients, and temperature difference delta (ΔT) across TEG.  The experimental system employed K-type thermocouples connected to an ESP32-based data acquisition system to measure the thermal response of the TEG under controlled operating conditions. The CFD model was used to evaluate the conjugate heat-transfer process between the exhaust-side components, TEG module, heatsink, and cooling airflow. The results indicate that increasing the heatsink size generally improves heat dissipation from the cold side and increases ΔT across the TEG. At 780 RPM, the CFD results showed ΔT values of 20.201, 20.337, and 20.455 °C for P90, P120, and P150, respectively, indicating a limited influence of heatsink geometry under lower thermal input conditions. At 1500 RPM, the corresponding ΔT values increased to 38.877, 42.129, and 44.168 °C, demonstrating a more pronounced effect of heatsink geometry under higher thermal and airflow conditions. Experimental results exhibited a similar increasing trend, although differences in the absolute ΔT values were observed. The findings demonstrate that heatsink geometry becomes increasingly important as the available exhaust heat and cooling airflow increase. This study provides a comparative evaluation of heatsink configurations for improving the thermal management of TEG-based waste heat recovery systems in diesel generator applications.