Maimun Zulhaidah Arthamin
Department of Clinical Pathology, Faculty of Medicine, Universitas Brawijaya/Dr. Saiful Anwar General Hospital, Malang

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Acute Myeloid Leukemia with Myelodysplasia-Related Changes (AML-MRC) with SH2B3, IDH2, CEBPA, RUNX1, and PRPF8 Mutations: A Case Report Kevin Reinaldo Sunjaya; Catherine Keiko Gunawan; Maimun Zulhaidah Arthamin; Budiono Raharjo; Stephani Linggawan; Friska Yulenta; Erica Valencia Immanuel; Anton Sumarpo; Siprianus Ugroseno Yudho Bintoro
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY Vol. 33 No. 1 (2026)
Publisher : Indonesian Association of Clinical Pathologists and Laboratory Medicine

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24293/ijcpml.v33i1.2663

Abstract

Acute myeloid leukemia with myelodysplasia-related changes (AML-MRC) is a diverse and intricate myeloid malignancy characterized by dysplasia in multiple blood cell types, cytogenetic abnormalities, and poor clinical outcomes. Genetic aberrations are fundamental to its development, with common mutations including SRSF2, SF3B1, ZRSF2, and U2AF1, which disrupt RNA splicing and impair hematopoiesis. This report details a rare case of AML-MRC in a 29-year-old female, initially presenting with 33.6% myeloblasts and 18.4% monoblasts in the bone marrow, later showing features of myelodysplasia, and ultimately relapsing with 94.3% myeloblasts. Comprehensive next-generation sequencing identified SH2B3, IDH2, CEBPA, RUNX1, and PRPF8 mutations, a profile more typical of de novo AML. These mutations disrupt key cellular processes such as cytokine signaling, epigenetic regulation, transcriptional control, and RNA splicing, contributing to genomic instability and disease progression. This case highlights significant laboratory findings, including initial high blast counts and the specific mutational landscape, underscoring the genetic heterogeneity of AML-MRC and emphasizing the necessity for thorough molecular profiling and targeted therapies to improve patient outcomes.
Comparison of Platelet Parameters Between Mindray BC-760 and Sysmex XN-1000 in Thrombocytopenic Patients Fendy Ferdian; Zaneth Gunawan; Fatimah Rizky Fitriani; Maimun Zulhaidah Arthamin
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY Vol. 33 No. 1 (2026)
Publisher : Indonesian Association of Clinical Pathologists and Laboratory Medicine

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24293/ijcpml.v33i1.2664

Abstract

This study compares platelet parameters in thrombocytopenic patients using the Mindray BC-760 and Sysmex XN-1000 hematology analyzers. This study was conducted at Dr. Saiful Anwar Hospital from March to June 2023, including 109 thrombocytopenic patients. Platelet parameters, including platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), plateletcrit (PCT), platelet-large cell ratio (P-LCR), and IPF, were measured using both analyzers. The Mindray BC-760 showed significantly higher platelet counts compared to the Sysmex XN-1000, with a mean platelet count of 53,730.908 ± 5,146.488/µL for the Mindray BC-760 and 29,029.336 ± 2,780.506/µL for the Sysmex XN-1000. Similar differences were observed for other parameters, including P-LCR, MPV, PCT and IPF. Passing-Bablok regression analysis revealed small biases for the measured parameters, with proportional bias noted for platelet count and IPF. Spearman correlation analysis showed very strong correlations (r ≥ 0.80) for platelet count, indicating reliable measurements across both analyzers. Strong correlations were found for PCT and IPF, moderate correlations for MPV and P-LCR, and weak correlations for PDW. These findings suggest that measuring platelet parameters using Mindray BC-760 is not different from using Sysmex XN-1000 in thrombocytopenic patients. However, caution is needed when interpreting PDW due to notable differences. That measuring platelet parameters using Mindray BC-760 is not different from using Sysmex XN 1000 in thrombocytopenic patients.