The design of a five-story Civil Engineering lecture building at Politeknik Negeri Pontianak was carried out with an emphasis on efficiency while ensuring safety against seismic loads. The building, measuring 39 × 16 m, utilizes reinforced concrete with a compressive strength of 30 MPa and reinforcement steel with yield strength of 280 MPa and 420 MPa. The structural system adopts a Special Moment Resisting Frame (SMRF) in accordance with SNI 1726-2019, SNI 1727-2020, and SNI 2847-2019. Structural analysis was performed using ETABS with a 3D frame model, while material estimation was obtained through Building Information Modeling (BIM) using ALLPLAN Engineering. The results indicate that beams, columns, slabs, and foundations meet the required strength and ductility criteria. The roof, ground-floor, and second- to fifth floor slabs have a thickness of 130 mm with Ø10 – 150 mm reinforcement, while the staircase slab uses shrinkage reinforcement Ø10 – 200 mm. Main beams are sized 300 × 500 mm with D19 mm reinforcement, secondary beams 200 × 400 mm with D13 mm support reinforcement and D16 mm span reinforcement, and columns 500 × 500 mm with primary reinforcement as required. Shear reinforcement spacing is set at 220 mm, with plastic hinge regions using stirrups 2Ø10 – 150 mm and non-plastic regions 2Ø10 – 220 mm. The pile cap foundation consists of two types, sized 1,500 × 1,500 × 600 mm and 800 × 1,500 × 600 mm. Based on BIM Quantity Take-Off (QTO), the concrete volume is 305.007 m³ and reinforcement weight reaches 83,834.37 kg. The application of BIM enhances planning efficiency and supports material management and construction processes, ensuring the building design meets strength, ductility, and implementation effectiveness standards.