Claim Missing Document
Check
Articles

Found 2 Documents
Search

ANALISIS PROFIL RESPONS SENSOR GAS MOS TERHADAP FORMALIN DAN BORAKS PADA MIE BASAH DAN AGAR-AGAR MENGGUNAKAN ELECTRONIC NOSE DAN PRINCIPAL COMPONENT ANALYSIS (PCA) Ifa Fitriani; Rohim Aminullah Firdaus; Zainul Arifin Imam Supardi; Wildan Panji Tresna
Inovasi Fisika Indonesia Vol. 15 No. 3 (2026): Vol 15 No 3
Publisher : Prodi Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/ifi.v15n3.p430- 443

Abstract

The misuse of formalin and borax in wet noodles and agar remains a food safety concern in Indonesia due to their potential health risks. Conventional analytical methods require complex sample preparation and high costs, highlighting the need for alternative approaches that are rapid and non-destructive. This study aimed to analyze the response characteristics of eight Metal Oxide Semiconductor (MOS) gas sensors (MQ3, MQ4, MQ6, MQ135, MQ136, MQ137, TGS822, and MS1100) in an electronic nose system to varying concentrations of formalin and borax (1–5%), and to evaluate the ability of Principal Component Analysis (PCA) to reduce dimensionality and visualize sensor response patterns. Sensor signals were baseline-corrected and extracted into four features (ΔVmax, AUC, slope, and steady-state), resulting in a 32-feature matrix that was standardized using Z-score normalization prior to PCA. The results showed that the first two principal components (PC1–PC2) explained 50.5% of the variance in agar and 58.7% in wet noodles. Visually, the response patterns of formalin- and borax-containing samples showed a clearer tendency toward separation in agar than in wet noodles. However, the silhouette scores in the PC1–PC2 space were relatively similar, at 0.285 for agar and 0.288 for wet noodles. The TGS822 sensor exhibited a clear difference in ΔVmax magnitude between formalinand borax-containing samples. These findings indicate the potential of MOS sensor arrays for characterizing differences in the responses to the two types of adulterants across food matrices, although PCA remains exploratory and has not achieved complete pattern separation.
EVALUASI KINERJA SISTEM ELECTRONIC NOSE BERBASIS SENSOR ARRAY MOS DENGAN PRINCIPAL COMPONENT ANALYSIS (PCA) UNTUK DETEKSI FORMALIN DAN BORAKS TAHU DAN BAKSO Redita Vivi Septiana Septiana; Dzulkiflih Dzulkiflih; Endah Rahmawati; Rohim Aminullah Firdaus; Wildan Panji Tresna
Inovasi Fisika Indonesia Vol. 15 No. 3 (2026): Vol 15 No 3
Publisher : Prodi Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/ifi.v15n3.p444-452

Abstract

Formalin and borax remain commonly misused as illegal preservatives in tofu and meatballs in Indonesia, creating a need for rapid, non-destructive detection methods. This study aims to evaluate the performance of an electronic nose (e-nose) system based on an eight-channel Metal Oxide Semiconductor (MOS) sensor array combined with Principal Component Analysis (PCA) for differentiating the response patterns of formalin and borax in tofu and meatballs. A total of 80 measurement sessions were collected across four adulterant-matrix combinations at five concentration levels with four replicates each. Sensor signals were baseline-corrected, extracted into 32 features (ΔVmax, AUC, slope, Vss), standardized using StandardScaler (Z-score), and dimensionally reduced through PCA, evaluated based on explained variance proportion, principal component score distribution, and sensor loading contributions. Results show that for the tofu matrix, the first two principal components explained 59.4% of the data variance with a partial separation trend between formalin and borax classes, whereas for the meatball matrix they explained 64.2% of the variance with overlapping score distributions. The MS1100 sensor was found to be the most sensitive to both adulterants. This study contributes a quantitative mapping of PCA performance as a pre-classification stage, which has rarely been explicitly reported in Indonesian e-nose literature, along with insight into the selectivity characteristics of MOS sensors toward two adulterant types across two different food matrices.