Claim Missing Document
Check
Articles

Found 2 Documents
Search

Perbandingan Daya Dukung Tiang Pancang dengan Metode Statis dan Dinamis pada Proyek SBE Plant PT.Ecooils Jaya Indonesia J, Kezia Nadella; Wardani, Mila K; DS, Arintha Indah; NA, M Ferdaus
Prosiding Seminar Nasional Sains dan Teknologi Terapan 2019: Menuju Penerapan Teknologi Terbarukan pada Industri 4.0: Perubahan Industri dan Transformasi P
Publisher : Institut Teknologi Adhi Tama Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (334.768 KB)

Abstract

Pada pembangunan SBE Plant PT.Ecooil Jaya Indonesia direncanakan menggunakan pondasi dalam berupa tiang pancang. Perencanaan awal tiang pancang direkomedasikan bentuk tiang persegi 35 x 35, 40 x 40, dan 45 x45 dengan kedalaman tiang pancang mencapai 28 m berdasarkan perhitungan daya dukung metode statis konvensional. Beban yang akan bekerja di atas tanah dasar direncakan sebesar 141.14 ton. Dari hasil penyelidikan tanah nilai NSPT terkoreksi dimulai pada kedalaman 20 ? 40 m dengan nilai NSPT 16 ? 38 jenis tanah pasir halus dan pasir halus kelanauan. Pada kedalaman 0 ? 20 m tanah dasar adalah tanah lanau kelempungan nilai NSPT 1 ? 5. Perencanaan tiang pancang selanjutnya dilakukan dengan metode statis probabilistik dengan dibandingkan terhadap daya dukung dinamis menggunakan Formula Gates. Tiang pancang yang direncanakan dengan dimensi lingkaran ? 45 cm dan asumsi penggunaan alat pemancangan menggunakan Drop Hammer. Hasil Perhitungan daya dukung statis metode LRFD sebesar 58,51 ton hingga 97,04 ton pada kedalaman 21 ? 24 m lebih kecil dari daya dukung dinamis yaitu 108 ton. Nilai tersebut memenuhi persyaratan bahwa daya dukung statis harus lebih kecil dari daya dukung dinamis.
Comparison of Design Requirements for Non-Anchored and Anchored Sheet Piles as Retaining Wall in a Basement Wardani, Mila K; Utami, Gati Sri; Syafiarti, Arintha I D; Lestari, Laras L
Journal of Earth and Marine Technology (JEMT) Vol 4, No 2 (2024)
Publisher : Lembaga Penelititan dan Pengabdian kepada Masyarakat - Institut Teknologi Adhi Tama Suraba

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.jemt.2024.v4i2.5959

Abstract

The construction of a 9-meter deep basement on clay soil with a soft consistency necessitates the use of a sheet pile for soil retention. Selected due to the soft soil conditions and a high groundwater level at the site, the sheet pile effectively addresses these challenges. The design calculations for the sheet pile, based on the Terzaghi concept, incorporated both active and passive earth pressures determined using the Rankine method. Analysis revealed a lateral force of 19,624 t/m² at a depth of 9 meters. The resulting design specifies a 10-meter embedded concrete pile without anchors, requiring a total sheet pile length of 19 meters. The chosen sheet pile type is W-600 A-1000. Alternatively, with anchors, the design calls for a 4-meter depth using type W-325A-1000 concrete sheet pile, with one anchor installed at a depth of 3 meters. The anchor's tensile strength is 5.46 tonnes, resisting a force of 113.817 Tm with a diameter of 5 cm. Modelling analysis showed that unanchored sheet piles have a safety factor of 0.770 and exhibit lateral deformation of 0.00803 meters. Conversely, the addition of anchors enhances the safety factor to 1.146 and increases lateral deformation to 0.0195 meters, indicating that anchors significantly improve safety and reduce deformation.