Claim Missing Document
Check
Articles

Found 2 Documents
Search

PELATIHAN PRODUKSI FILM PENDEK FIKSI DI SMA 1 PADANGPANJANG Pradhono, Choiru; Arzul, Arzul; Andhika, Veggy; Hamdi, Khairil
Batoboh Vol 1, No 1 (2016): Batoboh -Jurnal Pengabdian Pada Masyarakat
Publisher : Institut Seni Indonesia Padangpanjang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26887/bt.v1i1.148

Abstract

Film sudah menjadi sebuah seni yang sangat dekat dengan masyarakat saat ini. Film beberapa tahun terakhir menjadi bagian dari lomba kesenian siswa-siswa SMA ditingkat nasional yang bernama FLS2N (Festiva Dan Lomba Seni Siswa Nasional) yang secara reguler diadakan berkala setiap tahun. Siswa siswi SMAN 1 Padangpanjang terlibat menjadi salah satu peserta pada kegiatan tersebut dan karena masih belum memahami proses produksi film fiksi secara benar dan tepat yakni mengikuti tahapan pra produksi, produksi dan paska produksi maka dibutuhkan penambahan wawasan dan pelatihan. Produksi film sebelumnya yang dilakukan hanya sebatas perekaman atau pendokumentasian tanpa mempertimbangkan persiapan pra produksi, produksi, paska produksi, tata artistik, unsur sinematografi, mise and scene dan konsep estetika film lainnya. Produksi yang dlilakukan lebih kepada improvisasi pendokumetasian tidak kepada petimbangan-pertimbangan unsur yang telah diuraikan tersebut. Hal tersebut berakibat pada belum memenuhi unsur sebuah film fiksi yang benar dan baik dalam menyampaikan pesannya. Untuk itu, dalam menambah wawasan dan pengetahuan siswa siswi SMAN 1 Padangpanjang perlu diadakan pelatihan terkait dengan produksi film pendek fiksi
Analisis Rugi Daya Akibat Partial Discharge pada Generator Turbin Gas di North Duri Cogeneration Plant Arzul, Arzul
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 6 No. 1 (2023): April 2023
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v6i1.14697

Abstract

The function of the generator is to produce electrical energy from the mechanical energy that rotates it. However, in a system for the generation of electrical energy, there are possibilities for interference with the generator which can cause the generator to suffer damage. One of the disturbances that often occurs in generators is short circuit faults. Short circuit disturbances in generators can be caused by various things, which is an example of an insulation failure in the stator winding is called Partial Discharge. The failure of the insulation that occurs in the stator winding is the most dominant cause of damage to the generator. However, in operation, many factors cause a decrease in the quality of the insulation of the stator winding, including pressure factors that are electrical, mechanical and thermal. Partial discharge in the generator stator winding can also cause power losses in the generator. Power loss occurs due to the control of electric charge within a certain time frame during the partial discharge activity. By using the formula calculation, the value of the power loss that occurs due to partial discharge can be identified and analyzed to determine the condition of the generator. Partial discharge measurements were carried out using the IRIS POWER TGA-BTM Portale Partial Discharge (PD) Monitoring tool and the PDLitePro software. The object of study is the North Duri Cogeneration Generator Unit 1. Based on the results of comparative analysis, the measured PD magnitude was 160 mV in the isolation of the generator stator winding Unit-1 Phase A, 134 mV in the isolation of the generator stator winding Unit-2 Phase B and 124 mV in the isolation of the generator stator winding Unit-3 Phase C entered into Typical PD category level (<75 % Summary of Statistics). In addition, the generator Unit-1 has the highest magnitude when compared to Unit-2 (134 mV) and Unit-3 (124 mV). However, in general, PD activity in Unit-1 winding isolation is still within safe limits up to 160 mV. The value of the power loss due to a significant partial discharge that occurred in the North Duri Cogeneration Plant generator was in phase A of all phases that occurred and occurred on March 25 2019 with a power loss value of 8.70 mW.