Analisis Informasi Citra Anatomi Ureter antara Safire dengan Filtered Back Projection pada Teknik Tracking CT Urologi Klinis Hidronefrosis Zakiah, Putri Vina; Rasyid, Rasyid; Prastanti, Agustina Dwi; Sulistiyadi, Akhmad Haris; Sudiyono, Sudiyono; Susanti, Maya
Jurnal Imejing Diagnostik (JImeD) Vol 11, No 1 (2025): JANUARY 2025
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v1i1.11684

Abstract

Background: Clinical CT-Scan Examination and Noise Reduction in Hydronephrosis. Non-contrast CT-Scan examination is used to diagnose hydronephrosis and enhance diagnostic information in CT Urology tracking. However, CT Urography images often contain high noise levels due to examination parameters and patient size variations, which can obscure small anatomical details like the ureter. To improve image quality, reconstruction algorithms such as Filtered Back Projection (FBP) and Iterative Reconstruction (IR), particularly SAFIRE, are used alongside denoising techniques to reduce noise while preserving diagnostic information.This research aims to find the most optimal reconstruction algorithm for processing images regarding ureter anatomical information in tracking CT Urology techniques for clinical hydronephrosis.Methods: This is a quasi-experiment using the static group comparison method. Non-contrast CT (NCCT) Urology examination images in hydronephrosis patients were processed with FBP and SAFIRE strength 3 reconstruction algorithms. Assessment of anatomical image information analysis was conducted quantitatively by measuring noise and assessing anatomical information by respondents.Results: The results of this study are differences in anatomical information on Urology CT tracking images with variations in FBP and SAFIRE reconstruction algorithms with a p-value of 0.00 (0.05 The study results showed significant differences in ureter anatomical information between CT Urology tracking images reconstructed with FBP and SAFIRE algorithms (p-value = 0.00 0.05). The alternative hypothesis was accepted, indicating that SAFIRE is more effective than FBP in reducing noise in CT Urology tracking images.Conclusions: SAFIRE produces higher image quality and lower noise in non-contrast CT Urology.
Hubungan Pengetahuan dan Kepatuhan Penerapan Proteksi Radiasi: Studi pada Mahasiswa Praktik Klinik Jurusan Teknik Radiodiagnostik dan Radioterapi, Poltekkes Kemenkes Semarang Sulistiyadi, Akhmad Haris; Abimanyu, Bagus; Kartikasari, Yeti; Isnoviasih, Susi Tri
Jurnal Imejing Diagnostik (JImeD) Vol. 9 No. 1: JANUARY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i1.10442

Abstract

Background: Radiation protection is very important for patient and personnel safety in radiology services. It has been given in the college through classical lectures, including in Radiodiagnostic and Radiotherapy Department Poltekkes Kemenkes Semarang. The student’s knowledge is routinely evaluated but their compliance in the clinical activities has never been specifically observed. This study aims to find out the relationship between knowledge toward compliance of the application of radiation protection on clinical practice students.Methods: This is quantitative research with a cross-sectional design. Research was conducted on 90 second-year clinical internship students of the Radiodiagnostic and Radiotherapy Department. The level of knowledge was measured by written test, while the level of compliance was observed by clinical observation. The affecting factors are investigated through indepth interview. Data were analyzed by Spearman Rank Correlation.Results: The knowledge levels among the students were "excellent” (18%), "good" (68%), and "fair" (14%). The radiation protection compliance levels were "good" (73%) and "very good" (27%). There was a significant relationship between radiation protection knowledge level toward radiation protection compliance (p value <0.05). The strength of the relationship was low (coefficient interval = 0.257). Conclusions: There was a relationship between knowledge and the level of compliance, but it was not the only influencing factor. The environment tends to have an effect on the level of compliance. Radiographers and clinical instructors should be good role model in applying radiation protection.
Analisis Informasi Citra Anatomi Ureter antara Safire dengan Filtered Back Projection pada Teknik Tracking CT Urologi Klinis Hidronefrosis Zakiah, Putri Vina; Rasyid, Rasyid; Prastanti, Agustina Dwi; Sulistiyadi, Akhmad Haris; Sudiyono, Sudiyono; Susanti, Maya
Jurnal Imejing Diagnostik (JImeD) Vol. 11 No. 1 (2025): JANUARY 2025
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v1i1.11684

Abstract

Background: Clinical CT-Scan Examination and Noise Reduction in Hydronephrosis. Non-contrast CT-Scan examination is used to diagnose hydronephrosis and enhance diagnostic information in CT Urology tracking. However, CT Urography images often contain high noise levels due to examination parameters and patient size variations, which can obscure small anatomical details like the ureter. To improve image quality, reconstruction algorithms such as Filtered Back Projection (FBP) and Iterative Reconstruction (IR), particularly SAFIRE, are used alongside denoising techniques to reduce noise while preserving diagnostic information.This research aims to find the most optimal reconstruction algorithm for processing images regarding ureter anatomical information in tracking CT Urology techniques for clinical hydronephrosis.Methods: This is a quasi-experiment using the static group comparison method. Non-contrast CT (NCCT) Urology examination images in hydronephrosis patients were processed with FBP and SAFIRE strength 3 reconstruction algorithms. Assessment of anatomical image information analysis was conducted quantitatively by measuring noise and assessing anatomical information by respondents.Results: The results of this study are differences in anatomical information on Urology CT tracking images with variations in FBP and SAFIRE reconstruction algorithms with a p-value of 0.00 < (0.05 The study results showed significant differences in ureter anatomical information between CT Urology tracking images reconstructed with FBP and SAFIRE algorithms (p-value = 0.00 < 0.05). The alternative hypothesis was accepted, indicating that SAFIRE is more effective than FBP in reducing noise in CT Urology tracking images.Conclusions: SAFIRE produces higher image quality and lower noise in non-contrast CT Urology.