Sasotya, Raden Mas Sonny
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Kejadian Ballooning dan Avulsi Otot Levator Ani Pada Persalinan Spontan Primipara Non OASIS di Fasilitas Kesehatan Tingkat Pertama Rahman, Muhammad Nurhadi; Sukarsa, Mochamad Rizkar Arev; Rinaldi, Andi Rinaldi; Achmad, Eppy Darmadi; Sasotya, Raden Mas Sonny; Armawan3, Edwin
Indonesian Journal of Obstetrics & Gynecology Science Volume 7 Nomor 1 Maret 2024
Publisher : Dep/SMF Obstetri & Ginekologi Fakultas Kedokteran Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24198/obgynia.v7i1.639

Abstract

Pendahuluan: Kerusakan otot levator ani, seperti Ballooning dan Avulsi, sering terjadi pada Obstetric Anal Sphincter Injuries (OASIS) saat persalinan, yang menyebabkan masalah jangka panjang seperti inkontinensia dan prolaps uteri. Namun, hubungan antara kerusakan ini dengan robekan perineum derajat ringan atau Non-OASIS masih kurang dipahami. Penelitian ini bertujuan untuk mengeksplorasi prevalensi Ballooning dan Avulsi pada persalinan spontan primipara Non-OASIS tanpa episiotomi di fasilitas kesehatan tingkat pertamaMetode: Studi cross-sectional dilakukan di Rumah Sakit Umum Pusat Dr. Sardjito Yogyakarta dan praktik mandiri bidan di Sleman, Yogyakarta, melibatkan 69 pasien. Penggunaan USG 3D melalui pendekatan translabial digunakan untuk mengidentifikasi Ballooning dan Avulsi.Hasil: Dari 69 pasien yang mengalami persalinan spontan primipara Non-OASIS tanpa episiotomi yang terlibat dalam penelitian ini, 66,67% pasien mengalami robekan perineum derajat ringan, sementara 33,3% memiliki perineum intak. Prevalensi Ballooning adalah 26,1% dan Avulsi adalah 17,4%. Ballooning lebih umum terjadi pada pasien dengan robekan perineum derajat ringan (32,6%) daripada yang memiliki perineum intak (13,0%). Avulsi juga lebih sering terjadi pada pasien dengan robekan perineum derajat ringan (21,7%) dibandingkan dengan yang memiliki perineum intak (8,7%).Kesimpulan: Avulsi terjadi pada satu dari empat persalinan spontan primipara Non-OASIS tanpa episiotomi, sementara Ballooning terjadi pada satu dari enam persalinan. Studi ini memberikan wawasan tentang karakteristik kerusakan otot levator ani dalam setting praktik kebidanan mandiri yang berjejaring dengan fasilitas kesehatan tingkat pertama.The occurance of Ballooning and Avulsion of The Levator Ani Muscles in First Spontaneous Vaginal Birth Non-OASIS without Episiotomy at Primary Health FacilitiesAbstract Introduction: Damage to the levator ani muscles, such as Ballooning and Avulsion, often occurs during Obstetric Anal Sphincter Injuries (OASIS) during childbirth, leading to long-term issues like incontinence and uterine prolapse. However, the relationship between this damage and mild perineal tears or Non-OASIS is not fully understood. This study aims to explore the prevalence of Ballooning and Avulsion in spontaneous primiparous deliveries without episiotomy in primary healthcare facilities.Method: A cross-sectional study was conducted at Dr. Sardjito General Hospital in Yogyakarta and midwifery practices in Sleman, Yogyakarta, involving 69 patients. 3D ultrasound via translabial approach was used to identify Ballooning and Avulsion.Results: Out of 69 patients undergoing spontaneous primiparous deliveries without episiotomy, 66.67% experienced mild perineal tears, while 33.3% had intact perineum. The prevalence of Ballooning was 26.1% and Avulsion was 17.4%. Ballooning was more common in patients with mild perineal tears (32.6%) compared to those with intact perineum (13.0%). Avulsion also occurred more frequently in patients with mild perineal tears (21.7%) compared to those with intact perineum (8.7%).Conclusion: Avulsion occurs in one out of four spontaneous primiparous deliveries without episiotomy, while Ballooning occurs in one out of six deliveries. This study provides insights into the characteristics of levator ani muscle damage in the setting of primary healthcare facilities connected to independent midwifery practices.Key words: levator ani muscle avulsion, levator ani muscle ballooning, primipara, mild perineal tear.
Risk of Malposition in a 56-Year-Old Female Lippes Loop IUD User: A Case Report Sepriano, Muhammad Ardi Levrian; Susilo, Artha Falentin Putri; Sasotya, Raden Mas Sonny
Indonesian Journal of Obstetrics & Gynecology Science Volume 8 Nomor 1 Maret 2025
Publisher : Dep/SMF Obstetri & Ginekologi Fakultas Kedokteran Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24198/obgynia.v8i1.766

Abstract

Introduction: The intrauterine device (IUD) stands as a widely utilized contraceptive modality globally, renowned for its effectiveness and long-term reliability. However, within the spectrum of potential complications, the occurrence of perforation, though rare, represents a significant concern due to its potential for serious sequelae. Perforation entails the unintended penetration of the uterine wall by the IUD, leading to its migration beyond the uterine cavity. Despite its gravity, perforation often presents as an asymptomatic phenomenon, with some cases remaining undetected for extended durations following insertion. Lippes loop IUD complications are relatively low risk like malposition, embedded, or perforation.Case Report: This study documents a notable case involving a 56-year-old, P1A0, who had been utilizing an intrauterine device for a remarkable 31-year period. Referred from Hermina Arcamanik Hospital, the patient sought intervention for IUD removal, notwithstanding the absence of associated symptoms. Notably, physical examination and laboratory analyses yielded unremarkable findings, highlighting the latent nature of this complication. Further diagnostic elucidation through ultrasound examination confirmed the presence of a Lippes Loop (LL) IUD embedded within the uterine cavity. The intrauterine device (IUD) became embedded, rendering it impossible to remove. The IUD extraction is performed using hysteroscopy. Subsequent peri hysteroscopic extraction of the IUD unveiled partial embedding within the posterior uterine cavity, necessitating precise intervention to mitigate potential complications. Fortunately, postoperative surveillance revealed an absence of pain or hemorrhagic complications, culminating in the patient’s discharge on the first postoperative day. Conclusion: Constituted primarily of plastic material, LL IUDs offer prolonged utility devoid of significant adverse sequelae, underscoring their role as a viable contraceptive option with a slight risk of embedded for women seeking enduring contraception.Risiko Malposisi pada Akseptor Lippes Loop IUD pada Wanita Usia 56 Tahun: Sebuah Laporan KasusAbstrakPendahuluan: Alat Kontrasepsi Dalam Rahim (AKDR) merupakan metode kontrasepsi yang banyak digunakan di seluruh dunia karena efektivitas dan keandalannya dalam jangka panjang. Namun, di antara berbagai potensi komplikasi, perforasi menjadi salah satu kekhawatiran utama meskipun jarang terjadi, mengingat potensi dampak serius yang dapat ditimbulkannya. Perforasi terjadi ketika IUD secara tidak sengaja menembus dinding rahim, menyebabkan migrasi IUD keluar dari kavitas uterus. Meskipun serius, komplikasi ini sering ersifat asimtomatik dan tidak terdeteksi dalam jangka waktu lama setelah pemasangan. Komplikasi IUD tipe lippes loop dapat terjadi seperti malposisi, embedded atau perforasi, tetapi pada kasus yang jarang. Presentasi Kasus: Studi ini melaporkan kasus menarik pada seorang wanita berusia 56 tahun, P1A0, yang telah menggunakan IUD selama 31 tahun. Pasien dirujuk dari RS Hermina Arcamanik untuk menjalani prosedur pengangkatan IUD, meskipun tidak mengalami gejala terkait. Pemeriksaan fisik dan analisis laboratorium tidak menunjukkan kelainan, menekankan sifat laten komplikasi ini. Pemeriksaan ultrasonografi lebih lanjut mengonfirmasi keberadaan IUD jenis Lippes Loop (LL) yang tertanam di dalam kavitas rahim. Prosedur histeroskopi dilakukan karena IUD tertanam di dalam kavitas rahim sehingga membuat IUD sulit untuk diekstraksi secara normal. Saat prosedur histeroskopi, ditemukan bahwa sebagian IUD tertanam di dinding posterior rahim, memerlukan intervensi presisi guna mencegah komplikasi lebih lanjut. Pemantauan pascaoperasi tidak menunjukkan adanya nyeri atau komplikasi perdarahan, dan pasien dipulangkan pada hari pertama setelah operasi.Kesimpulan: Karena terbuat dari bahan dasar plastik, IUD LL menawarkan masa pemakaian yang lama tanpa menimbulkan efek samping yang signifikan, menjadikannya pilihan kontrasepsi yang andal, namun dengan risiko kecil terjadi embedded bagi wanita yang mencari solusi kontrasepsi jangka panjang.Kata kunci: Alat kontrasepsi dalam rahim, embedded, lippes loop, risiko