Claim Missing Document
Check
Articles

Found 4 Documents
Search

STUDI EKSPERIMENTAL MODULUS OF RUPTURE DAN MODULUS OF ELASTICITY LAMINATED VENEER LUMBER KAYU SENGON Aswadi, Lalu Samsul; Yuwana, Dwi Sat Agus; Prawenti, Herlita
Jurnal Rekayasa Infrastruktur Sipil Vol 1, No 2 (2020): Jurnal Rekayasa Infrastruktur Sipil
Publisher : Universitas Tidar

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (28.273 KB) | DOI: 10.31002/.v1i2.3396

Abstract

Kayu sengon dengan nama ilmiah Paraserianthes falcataria yaitu suatu jenis kayu yang pertumbuhannya cepat tetapi kekuatannya kecil sehingga kayu jenis ini biasanya jarang digunakan untuk bahan struktur bangunan.. Salah satu cara untuk meningkatkan kekuatan kayu sengon yaitu dengan teknologi LVL (Laminated Veneer Lumber).Penelitian ini bertujuan untuk mendapatkan nilaiModulus of Rupture(MOR) dan Modulus of Elasticity(MOE) LVL kayu Sengon dari pengujian lentur secara eksperimental.Hasil penelitian ini diharapkan dapat memberikan sumbangan ilmiah untuk basis data sifat mekanika kayu Indonesia dan khususnya untuk perencanaan komponen struktur tekan dan lentur. Benda uji LVL kayu Sengon sebanyak 8 buah dengan dimensi 480 mm x 80 mm x 40 mm ditumpu di kedua ujungnya. Benda uji kemudian diberi beban lentur ditengah-tengah secara beangsur-angsur sampai benda uji runtuh. Kemudian dicatat berapa beban yang mampu ditahan oleh masing-masing benda uji. Dari hasil pengujian kuat lentur tersebut kemudian dihitung Modulus of Rupture(MOR) dan Modulus of Elasticity(MOE) LVL kayuSengon dari masing-masing benda uji.Dari pengujian didapatkan hasil MOR dari 8 benda uji berturut-turut yaitu 30,08 Mpa, 39,14 Mpa, 39,14 Mpa,33,96 Mpa, 35,90 Mpa, 38,17 Mpa, 39,78 Mpa dan 31,70 Mpa dengan nilai rata-rata MOR dari 8 bendauji adalah 35,98 Mpa. Hasil dari nilai MOE untuk 8 bendauji berturut-turut adalah 3436,36 Mpa, 3306,12 Mpa, 3306,12 Mpa, 3497,14 Mpa, 3469,88 Mpa, 3888 Mpa, 3353.23 Mpa dan 3351,72 Mpa dengan nilai rata-rata MOE dari 8 benda uji adalah3451,07 Mpa.
EVALUASI STRUKTUR RANGKA BAJA PADA GEDUNG PARKIR UNIVERSITAS TIDAR BERDASARKAN SNI-1729-2015 Fahri, Misbakhul; Arnandha, Yudhi; Yuwana, Dwi Sat Agus; Wicaksono, Teguh Mulyo
Bangun Rekaprima Vol. 8 No. 2 (2022): Oktober 2022
Publisher : Politeknik Negeri Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (557.207 KB) | DOI: 10.32497/bangunrekaprima.v8i2.3964

Abstract

Standar perencanaan baja meliputi dasar perencanaan, perilaku tegangan dan pengaruh stabilitas struktur baja sesuai SNI 1729 tentang Spesifikasi Untuk Bangunan Baja Struktural. Peraturan SNI 1729-2015, terdapat metode desain Direct Analysis Method (DAM) sebagai alternatif dari Effective Length Method (ELM) yang telah digunakan pada SNI 03-1729-2002. Gedung parkir Universitas Tidar dibangun tahun 2019 direncanakan menggunakan peraturan SNI 03-1729-2002 maka diperlukan tinjauan ulang menggunakan peraturan terbaru. Bangunan model rangka portal baja atau biasa disebut Sistem Rangka Pemikul Momen Khusus (SRPMK) pada kondisi tanah sedang (SD). Parameter respons spektral percepatan gempa berdasarkan peraturan SNI 1726-2019. Dalam periode fundamental struktur (T)terdapat faktor yang mempengaruhi berdasarkan kategori resiko antara lain Cu 1,4 , untuk rangka pemikul momen Ct 0,0724 dan x 0,8 , maka Ta didapatkan 0,608 detik, faktor sistem penahan gaya gempa Ω03, Cd 5,5, dan R 8. Didapatkan Cs sebesar 0,153 lebih besar dari Cs minimum 0,0406 maka koefisien respons seismik (Cs) sudah memenuhi ketentuan. Dari analisis massa ragam menunjukkan angka 0,999 dan 1 pada MODAL 12 yang menunjukkan partisipasi massa ragam telah mendekati 100% dan telah memenuhi syarat peraturan yang digunakan dengan mode getar translasi pada mode 1 dan 2 sedangkan mode 3 mulai bersifat rotasi. Simpangan terbesar ada pada lantai 3 yaitu sebesar 0,0067 dengan simpangan ijin maks adalah 0,065. Gaya dalam terbesar muncul akibat kombinasi   beban ke 4 yaitu 1,2 D+1,3W+γL L+0,5(La atau H). Dari SAP2000 pada elemen struktur gedung parkir Universitas Tidar tidak ada satupun elemen struktur yang berwarna merah over strenght (O/S) maka konstruksi dapat dikatakan aman
Pengaruh FAS Terhadap Kuat Tekan Beton Dari Agregat Sungai Krasak Aswadi, Lalu Samsul; Yuwana, Dwi Sat Agus
Abdimas Indonesian Journal Vol. 5 No. 1 (2025)
Publisher : Civiliza Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59525/aij.v5i1.633

Abstract

Concrete construction is widely used by the community, for example, building construction, bridge construction, port construction, girder construction, and others that require determining the quality of concrete. The use of concrete for protected and unprotected areas differs. In general, the community uses concrete construction for road hardening and for building their homes. In general, when mixing concrete, the water used during mixing tends to be free, without important rules, making it easy to work. This will affect the quality or grade of concrete. The research on the effect of water-cement ratio (W/C) on the compressive strength of concrete from Krasak river aggregates, as the main material that is currently widely available in the Krasak River, Pabelan River, and Kali Putih River. In these places, sand with various sizes and split or crushed stone from various stone crusher companies are available. This research follows the Indonesian National Standard (SNI) on the Selection of Concrete Mixtures for Normal Concrete, Heavy Concrete, and Mass Concrete. The concrete mixing is done with a volume ratio of 1pc:2ps:2split with six variations of W/C, namely 0.37, 0.46, 0.55, 0.61, 0.64, and 0.73. The sand and split materials are tested according to SNI, namely the testing of fine aggregate and coarse aggregate materials. Mix design is performed based on the data of fine and coarse aggregates. The test objects are made by mixing materials such as cement, sand, gravel, and water. The mixing is carried out by testing the fresh concrete or slump and making cylindrical test objects and soaking them for 28 days. Then, the compressive strength of the concrete is tested. The compressive strength test results show that the W/C ratios of 0.37, 0.46, 0.55, 0.61, 0.64, and 0.73 with slump values of 0, 3, 5, 8, 14, and 18 cm produce compressive strengths of 9.90, 13.75, 14.62, 20.18, 13.50, and 6.97 kg/cm2, respectively. From the test results, it can be seen that the best W/C ratio is 0.61 with a compressive strength of 20.18 kg/cm2.
The Effect of Compressive Strength of Concrete with Styrofoam Waste Cement Coating on Acid Solution and Water Permeability: Pengaruh Kuat Tekan Beton Dengan Coating Cement Limbah Styrofoam Terhadap Larutan Asam Dan Permeabilitas Air Sarjano, Belany Try Aji; Aswadi, Lalu Samsul; Yuwana, Dwi Sat Agus
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v7n1.p8-16

Abstract

This research analyze the effect of styrofoam cement coating as a protective layer on normal concrete in terms of physical quality and compressive strength when exposed to Natrium Sulfat acidic solution. Styrofoam-based cement coating is chosen due to water-resistant physical properties and its ability to reduce difficult-to-decompose waste. The method related to the effect of cement styrofoam coating as a liner with cylindrical concrete test objects measuring 15 cm in diameter and 30 cm in height and a quality of fc' 20 MPa, where its implementation is based on SNI 7656-2012. The cement coating used utilizes various mixture ratios of 0%, 40%, 50%, and 60% of the solvent weight in the form of Pertalite. The process of immersion in sodium sulfate acid solution, compressive strength testing, and permeability testing were conducted in the Laboratory, Universitas Tidar. The results indicate that the addition of styrofoam cement coating can reduce the corrosive impact of Natrium Sulfat acidic solution. The 60% styrofoam mixture variation showed the best results in three testing aspects: a post-curing compressive strength test value of 21.3621 MPa, a post-immersion in Natrium Sulfat acidic solution compressive strength test value of 20.7680 MPa, and a permeability test value of 7.03x10-9.