PERANCANGAN PERALATAN PENGKONDISIAN UDARA PADA RUANG MAKAN ASRAMA TOWER-II Khoirul Anam; Imam Haryadi Wibowo; Arfin Yusa Afriyanto
Langit Biru: Jurnal Ilmiah Aviasi Vol 9 No 3 (2016): Langit Biru: Jurnal Ilmiah Aviasi
Publisher : Politeknik Penerbangan Indonesia Curug

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (818.221 KB)

Abstract

Air conditioning is effort to give comfort and freshness. Air conditioning is needed to absorb heat from a room and to create comfort environment in a room. Air Conditioning (AC) Split Duct is used to create comfort environment that AC Split Duct can supply fresh air into the room that needed it. Fresh air supplied to circulating the air in the room to keep quality of air in the room. Source of polluter can be from inside of the room or outside. Polluted air from the room discarded through return then to exhaust duct while polluted air from outside of the room strained through filter media. Conditioned Air by AC Split Duct distributed through supply duct to the room. Conditioned air enter the from via diffuser. Air in the room exit through return grill then some of returned air circulated back to AC Split Duct and the rest exit through exhaust duct. This design will tested through software, Ansys CFX. Ducting system and Simulation of Air Conditioning Process in the Dining Room at Tower-II Dormitory will be tested.
ANALISIS PENGARUH PEMELIHARAAN DAN OPERASIONAL TERHADAP KERJA GARBARATA DI TERMINAL 2F BANDAR UDARA INTERNASIONAL SOEKARNO HATTA Asep Irawan; Nurhedhi Desryanto; Imam Haryadi Wibowo
Langit Biru: Jurnal Ilmiah Aviasi Vol 11 No 2 (2018): Langit Biru: Jurnal Ilmiah Aviasi
Publisher : Politeknik Penerbangan Indonesia Curug

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (584.209 KB)

Abstract

Passenger comfort is important for Soekarno Hatta International Airport managers. Work from equipment is needed to maintain airport operations, as well as garbarata. Maintenance and operations are one factor in influencing the work of garbarata. Currently there is still a maintenance facility for damage to garbarata. Therefore, this is examined as a material that determines what is done to better maintain the work of garbarata
Analisa Aliran Distribusi Udara Dan Kenyamanan Thermal Menggunakan Metode Computational Fluid Dynamics (CFD) Di Ruang Panel Listrik Kantor Unit Penyelenggara Bandar Udara Budiarto Zulina Kurniawati; Oka Fatra; Imam Haryadi Wibowo; Muhammad Samudera Novarizki Adityanto Nursin; Dita Diana Sari
LONTAR Jurnal Teknik Mesin Undana (LJTMU ) Vol 13 No 02 (2026): Oktober 2026
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35508/ljtmu.v13i02.27593

Abstract

This study aims to analyze airflow distribution and thermal comfort levels in the electrical panel room of the Budiarto Airport Management Unit Office using Computational Fluid Dynamics (CFD). The room experiences high heat loads due to continuously operating electrical equipment, requiring an effective ventilation and cooling system. Data were collected through field measurements of temperature, humidity, and air velocity at several points, then simulated using ANSYS Workbench 18.1. The results show that the average air velocity decreased from 0.180 m/s to 0.156 m/s, while the temperature increased from 31.7°C to 36.1°C, with maximum temperatures exceeding 130°C near electrical equipment. These conditions indicate thermal stratification and uneven air distribution. Based on ASHRAE 55:2013, ISO 7730:2005, and SNI 6390:2020 standards, the recorded temperatures fall outside the thermal comfort range (23–26°C). The study concludes that the existing 2 PK Split AC system is not yet optimal and recommends optimizing the cooling layout, adding ventilation, and implementing an IoT-based temperature monitoring system to improve thermal efficiency and operational safety.