Claim Missing Document
Check
Articles

Found 3 Documents
Search

Studi Perbandingan selenoid kapiler dan selenoid ekspansi pada Mesin Es serta di kontrol Aplikasi Blynk Mustofa, Adi; ujang wiharja
Jurnal Ampere Vol. 8 No. 2 (2023): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31851/ampere.v8i2.11437

Abstract

Currently, the use of this ice machine still uses a solenoid connected to a capillary and the results cannotbe targeted. The use of an ice machine with the ESP8266 module is combined with the blynk applicationwhich is a combination with the Internet of Thinks (IoT) system which makes the performance of using theice machine can be run remotely or with a smartphone. Reduced costs and less operator effort to expendfor ice making. The ice machine was finally integrated with the ESP8266 Module, the blynk applicationand added with one solenoid connected to an expansion which functions as a substitute for the capillaryselenoid if the need for ice is needed quickly in the process and will return to the capillary selenoid duringnormal production. The results showed that the ice machine with capillary selenoid was slower in the iceproduction process with 1 hour of production time of 5 kg of ice and required electricity consumptionduring production of 0.814 KWH, while the ice machine after using selenoid expansion the machineproduction process was faster than the capillary selenoid system by producing ice production for 1 hourwith a yield of 8 kg of ice and requires electricity consumption during production of 0.855 KWH, withpressure for expansion of 18 bar.
PENERAPAN RELAKSASI AUTOGENIK PADA PASIEN DIABETES MELITUS TIPE 2 DENGAN KETIDAKSTABILAN KADAR GLUKOSA DARAH Mustofa, Adi; Sumarni, Tri; Siwi, Adiratna Sekar
Maternity and Neonatal : Jurnal Kebidanan Vol. 13 No. 1 (2025): Maternity and Neonatal : Jurnal Kebidanan
Publisher : Fakultas Ilmu Kesehatan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30606/jmn.v13i1.3090

Abstract

Instability of blood glucose levels is one of the signs that appears in patients with type 2 diabetes mellitus. The incidence of type 2 diabetes mellitus is increasing from year to year. This has an impact on uncontrolled blood glucose levels in type 2 diabetes mellitus patients. To describe care for type 2 diabetes mellitus patients with the problem of unstable blood glucose levels by providing autogenic relaxation. This scientific writing method uses a case study with a descriptive design. The respondent in this paper is 1 patient with a medical diagnosis of DM pedis dextra abscess in the Dahlia room at RSUD Dr. R. Goeteng Taroenadibrata Purbalingga. Nursing care is carried out for 4 days of treatment. The results showed that after being given treatment, especially autogenic relaxation, for 4 days, patients with unstable blood glucose levels experienced a decrease in blood glucose levels. After treatment for 4 days, providing autogenic relaxation can reduce blood glucose levels in patients with type 2 diabetes mellitus. Autogenic relaxation still needs to be given to patients with type 2 diabetes mellitus to maintain and reduce blood glucose levels independently
Studi Perbandingan selenoid kapiler dan selenoid ekspansi pada Mesin Es serta di kontrol Aplikasi Blynk Mustofa, Adi; ujang wiharja
Jurnal Ampere Vol. 8 No. 2 (2023): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31851/ampere.v8i2.11437

Abstract

Currently, the use of this ice machine still uses a solenoid connected to a capillary and the results cannotbe targeted. The use of an ice machine with the ESP8266 module is combined with the blynk applicationwhich is a combination with the Internet of Thinks (IoT) system which makes the performance of using theice machine can be run remotely or with a smartphone. Reduced costs and less operator effort to expendfor ice making. The ice machine was finally integrated with the ESP8266 Module, the blynk applicationand added with one solenoid connected to an expansion which functions as a substitute for the capillaryselenoid if the need for ice is needed quickly in the process and will return to the capillary selenoid duringnormal production. The results showed that the ice machine with capillary selenoid was slower in the iceproduction process with 1 hour of production time of 5 kg of ice and required electricity consumptionduring production of 0.814 KWH, while the ice machine after using selenoid expansion the machineproduction process was faster than the capillary selenoid system by producing ice production for 1 hourwith a yield of 8 kg of ice and requires electricity consumption during production of 0.855 KWH, withpressure for expansion of 18 bar.