Claim Missing Document
Check
Articles

Found 2 Documents
Search

Enhancing Health Services through Telemedicine: Addressing the Gaps in LBW Monitoring and Training at Puskesmas Gedangan, Sidoarjo Regency Guruh Irianto, Bambang; Luthfiyah, Sari; Gumiwang, Her; Mifthahul Maghfiroh, Anita; Kholik, Abdul
Frontiers in Community Service and Empowerment Vol. 3 No. 3 (2024): September
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v3i3.69

Abstract

Puskesmas in Sidoarjo Regency do not yet have facilities for monitoring LBW in real time via android either by health workers at the health centre or the patient's family. Puskesmas Gedangan serves communities spread across several villages with a coverage area spread across several villages. This is an obstacle for families to get access to monitor the patient's progress, because the patient is in the NICU or ICU room. Another thing is that there is no training for users in the use of telemedicine-based Baby Incubator equipment. The role of users and families of patients is very important to keep the equipment in good condition. However, operating trainings based on new technology for users have never been conducted. Efforts to solve the above problems are to carry out counselling and assistance in the use of baby incubator equipment to users including nurses, midwives and other non-health worker users, so as to increase the knowledge of officers or users which in turn will have an impact on increasing the productivity of officers or users and improving the quality of service at the health centre. The purpose of this Community Service is to increase the role and participation of Poltekkes Kemenkes Surabaya in improving the degree of public health in the Puskesmas Gedangan area, Sidoarjo Regency. The results of community service through the application of telemedicine-based Baby Incubator at Puskesmas Gedangan are increased knowledge and skills regarding telemedicine-based baby incubator equipment. This will improve health services, especially for babies who need intensive care. The implementation of this technology provides significant benefits, including increased accessibility of health services, speed of response to patient health conditions, family involvement in care, and efficient use of resources. Assistance to Puskesmas personnel and patient families in the form of training, monitoring and evaluation of the use of appropriate technology in the form of Telemedicine-based baby incubator utilization.
Analysis of Tube Leakage of X-Ray Radiation Using Geiger Muller Sensor Equipped with Data Storage Utomo, Bedjo; Indrato, Tribowo; Gumiwang, Her; Mudjiono, Urip; Ardiansyah, Bayu; Hossain, A K M Bellal; Wongpituk, Klarnarong
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 2 (2022): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.142

Abstract

X-ray radiation (ionization) cannot be felt directly by the five human senses. Therefore, radiation monitoring is needed, one of which by using a survey meter. The purpose of this research is to directly monitor the level of radiation exposure and leakage of X-ray tube containers in the work area. This was done to ensure the safety and health of workers in the radiation transmission area, so that it is in accordance with the ALARA (As Low As Reasonably Achievable) principle, which is stipulated in the Decree of the Minister of Health RI No. 1250/Menkes/SK/XII/2009 concerning Guidelines for Quality Control of Radiodiagnostic Equipment as Standard Values ​​for X-Ray Radiation Monitoring. This research is an experimental study with a survey meter equipment module design using a Geiger Muller sensor equipped with data storage. This module design method uses Arduino programming as data processing and is displayed on the CHARACTER LCD. Test analysis was carried out by comparing the measurement value of the module with the standard value as a standard for comparison. Based on the measurement results, the X-ray tube leak test value resulted in a standard AAT survey meter value of 0.001 both using a closed and unsupplied 2mm Pb circuit, namely 0.00097 mGy/hour and 0.00092 mGy/hour. Meanwhile, the results of the tube leakage test using a survey meter, both circuits, modules, and standard survey meters show a passing grade test value of < 1mGy/hour. In conclusion, the module design using the Geiger Muller sensor is feasible to use.