Effendy Arif
Department of Mechanical Engineering, Faculty of Engineering, Hasanuddin University, Jalan Perintis Kemerdekaan KM 10, Tamalanrea, Makassar 90245

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search
Journal : Jurnal MEKANIKAL

EFEK TEMPERATUR PIPA KAPILER TERHADAP KINERJA MESIN PENDINGIN Anwar, Khairil; Arif, Effendy; Piarah, Wahyu H.
Jurnal MEKANIKAL Vol 1, No 1 (2010)
Publisher : Jurnal MEKANIKAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (294.352 KB)

Abstract

The aims of this research are to obtain (1) the effect of the capillary tube temperature on the refrigerant condition and the refrigerating capacity in the refrigeration system and (2) the optimum temperature condition for obtain better system performance.This research was done in the Refrigeration System Laboratory at Tadulako University in Palu. The method applied in this research is an experimental method, with various temperature at capillary tube. Various temperature is obtained by placing capillary tube in freezer from other refrigeration system (refrigerator), through arrangement of thermostat.The result of this research indicates that decreasing cooling temperature of capillary tube causes refrigerating capacity and Coefficient of Performance of refrigeration system increases. Optimum performance of this examination during 30 minutes, obtained on the lowest thermostat temperature position that is –20°C ( position 7) with Coefficient of Performance (COP) of 2.71 Â