Flexible milimeter-wave microstrip patch antenna array for wearable RF energy harvesting applications Mohd Saiful Riza Bashri; Noor Amalina Ramli
International Journal of Electrical and Computer Engineering (IJECE) Vol 11, No 3: June 2021
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v11i3.pp1976-1984

Abstract

In this paper, a series-fed milimeter-wave microstrip patch antenna array operating at 28 GHz is presented for wearable radio-frequency (RF) energy harvesting applications. The antenna array is made of 4×4 rectangular microstrip elements on a polyethylene terephthalate (PET) substrate to provide conformability when directly attached on human body parts. A 4-way Wilkinson power divider is connected to the array for RF power combining. The overall size of the antenna is 47×28×0.25 mm. The half-power beamwidth (HPBW) of the antenna array can be increased up to 151.9⁰ via structural deformation making it suitable for energy harvesting applications. The performance of the antenna array is investigated in terms of impedance matching, gain and radiation pattern. The average simulated specific absorption rate (SAR) of the antenna is 0.52 W/kg which is well below the safety limit of 1.6 W/kg averaged over 1 g of tissue for 100 mW of input power.
Wearable antenna for non-invasive human arm bone fracture monitoring system Mohd Saiful Riza Bashri; Noor Amalina Ramli; Abang Muhammad Sufi Abang Madehan
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.11622

Abstract

This paper presents a flexible wearable monopole antenna for non-invasive monitoring of human arm bone fracture healing. The antenna is fabricated on a polyethylene terephthalate (PET) substrate and is intended for integration into an arm cast for continuous monitoring during healing. With dimensions of 77 mm×53 mm×0.2 mm, the antenna operates from 1.7 to 2.6 GHz in free space and exhibits resonance changes when placed on a human arm phantom. Bone healing is assessed through changes in the antenna reflection coefficient caused by variations in the dielectric properties around the fracture site. Experimental measurements show resonance at approximately 1.84 GHz without blood, 1.88 GHz with 10 ml of blood, and 1.82 GHz with 20 ml of blood, demonstrating sensitivity to changes associated with the healing process. The simulated specific absorption rate is 0.0452 W/kg at 1 mW transmitted power, within accepted safety limits. The agreement between simulation and measurement supports the feasibility of the proposed compact, low-cost, and non-invasive monitoring approach.