Partial Discharge Characterization based on Leakage Current Pulses Waveform for Contaminated Glass Insulator String N. A. Othman; M. A. M. Piah; Z. Adzis; Nasir A. Al-geelani
International Journal of Electrical and Computer Engineering (IJECE) Vol 6, No 2: April 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (16.951 KB) | DOI: 10.11591/ijece.v6i2.pp835-843

Abstract

This paper deals with the analysis of partial discharge (PD) occurrences based on leakage current (LC) pulses distribution under different level of contamination. In this work, laboratory based contamination performance tests are conducted on four units of glass insulator string stacked in I-position. Results show that PD can be characterized (according to their occurrence with respect to the AC supply) as follows: corona discharge occurring dominantly in lightly contaminated insulators, surface discharge occurring dominantly in medium contaminated insulators and finally internal discharge occurring dominantly in heavily contaminated insulators. The ability to distinguish the type of PDs from the LC waveform could be used to monitor and predict the condition of the insulator. The outcome can be incorporated in a conditioning monitoring system.
Evaluation of Residential Grid-Connected Photovoltaic System as the Potential Energy Source in Malaysia S. S. Abd Wahid; Z. Nawawi; M. I. Jambak; Y. Z. Arief; M. A. B. Sidik; M. W. Mustafa; Z. Adzis
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 14, No 4: December 2016
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v14i4.3818

Abstract

This paper is under in-depth investigation due to suspicion of possible plagiarism on a high similarity indexApplication of solar energy in Malaysia has been started in 1998. This country has a large potential of solar energy due to its location at equatorial region. The current energy consumption and demand in Malaysia is describes in this paper. The potential of solar energy in Malaysia is described together with the suitable photovoltaic construction. It also explains the plans conducted by Malaysia involving solar energy that covers investments and also projects involved such as Malaysia Building Integrated Photovoltaic (MBIPV). Simulation of grid-connected photovoltaic system in this study is performed using HOMER software. Finally, the potential of having a grid-connected PV system in a residential area is analyzed. The positive and negative findings in terms of cost and suitability of the system are explained.
Transformer Fault Early Warning System Model Using GSM Network M. A. M. Azmi; Z. Nawawi; M. I. Jambak; M. A. B Sidik; Y. Z. Arief; Z. Adzis; N. A. Muhamad
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 2: EECSI 2015
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (552.556 KB) | DOI: 10.11591/eecsi.v2.795

Abstract

This paper presents the design and implementation of amobile embedded system using an Arduino microprocessor to monitorand record key operational indicators of a distribution transformer,such as transformer oil level, temperature and vibration of adistribution transformer in a substation. If there is any abnormalityor an emergency situation, the system sends SMS (Short MessageService) messages to designated mobile telephones containinginformation about the abnormality of the mentioned parameters.Providing early warning of the abnormality of the distributiontransformer can be accomplished by shutting down the entire unitwith the aid on-line monitoring system integrates with Global ServiceMobile (GSM) Modem. Furthermore, the design generally consiststand-alone single chip microcontroller, modem and sensor packageslocated on distribution transformer site. In general, the design isdeveloped for the user to easily recognize the distribution transformerthat is suffered by any high vibration and rise in temperatures andlocated in remote or suburban area which is rarely and hard to reachfor manual monitoring. The ultimate objective is to monitor thetransformer oil level and temperature of 24 hours, 7 days a weekcontinuously besides the current and voltage parameter whichincluded in basis monitoring system