Design of a new backstepping controller for control of microgrid sources inverter Mahmoud Zadehbagheri; Mohammad Javad Kiani; Tole Sutikno; Rasoul Arvin Moghadam
International Journal of Electrical and Computer Engineering (IJECE) Vol 12, No 4: August 2022
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v12i4.pp4469-4482

Abstract

Emergency power supply is becoming an important capability for many home or industrial electronic and computer devices. Therefore, the performance of the designed uninterruptible power supplies (UPS) inverters has low distortion at the output voltage. Initially, such inverters were controlled by proportional integral (PI) control classic rules. This method is difficult to understand the limitations of stability and to apply transient response to strong external disturbances. In this paper, an inverter is simulated and offered for single-phase and three-phase voltage controlled by a non-linear controller. For this purpose, a comparison has been made between the controller performance and the PI controller. In the first step, there is a backstepping regulator that uses the stability tool next to the Lyapunov function. And the other regulator operates according to the PI method. The performance of these two regulators is simulated during a change in reference or a load change in MATLAB. Also, a method of feedback voltage control based on the Lyapunov theory for controlling of the distributed generation (DG) unit independent Inverter is presented. The proposed controller is not only simple, but also against the sudden changes in load and the unspecified system is resistant.
Comparative detection and fault location in underground cables using Fourier and modal transforms Vahdat Nazerian; Mohammad Esmail Zakerifar; Mahmoud Zadehbagheri; Mohammad Javad Kiani; Tole Sutikno
International Journal of Electrical and Computer Engineering (IJECE) Vol 12, No 6: December 2022
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v12i6.pp5821-5839

Abstract

In this research, we create a single-phase to ground synthetic fault by the simulation of a three-phase cable system and identify the location using mathematical techniques of Fourier and modal transforms. Current and voltage signals are measured and analyzed for fault location by the reflection of the waves between the measured point and the fault location. By simulating the network and line modeling using alternative transient programs (ATP) and MATLAB software, two single-phase to ground faults are generated at different points of the line at times of 0.3 and 0.305 s. First, the fault waveforms are displayed in the ATP software, and then this waveform is transmitted to MATLAB and presented along with its phasor view over time. In addition to the waveforms, the detection and fault location indicators are presented in different states of fault. Fault resistances of 1, 100, and 1,000 ohms are considered for fault creation and modeling with low arch strength. The results show that the proposed method has an average fault of less than 0.25% to determine the fault location, which is perfectly correct. It is varied due to changing the conditions of time, resistance, location, and type of error but does not exceed the above value.
Optimal placement of the phasor measurement units using differential evolution algorithm Mahmoud Zadehbagheri; Alireza Abbasi; Tole Sutikno
Indonesian Journal of Electrical Engineering and Computer Science Vol 31, No 2: August 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v31.i2.pp1211-1222

Abstract

The increasing consumption of the electric energy aimed at develop the transmission networks and the demand for higher reliability from the network; in this regard, wide-area measurement systems using phasor measurement units (PMUs) have revolved the trend of power network management. In this paper, the optimal allocation of PMUs in order to reach the perfect observability of the network; based on a differential evolution algorithm, is proposed and it is shown that, the deployment of constraints related to the zero-injection busses (ZIB) aimed to decrease the number of PMUs and their corresponding cost. By comparing the proposed method to the other methods, its simplicity and good performance are approved.
Proposing a new method for calculating DC sources in an extended multilevel converter Afzal Keivanlou Shahrestanaki; Rahim Ildarabadi; Mahmoud Zadehbagheri; Tole Sutikno
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 22, No 1: February 2024
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v22i1.25707

Abstract

In this paper, we propose a method for calculating the DC source amplitude in an extended multilevel inverter (MLI) structure so that the maximum number of levels and the output voltage waveform are as close as possible to the sinusoidal wave with minimum total harmonic distortion (THD). For the developed structure, three algorithms are suggested to determine the amounts of DC voltage resources. The first important point about choosing the right amounts for the DC resources is that the number of levels should be as large as possible, and the second important point is that the intervals between the levels should be the same throughout the waveform. By observing these two points, the output voltage waveform can be as near as possible to the sinusoidal wave that we want. In this study, we used iteration-based methods to find suitable values for DC sources. Simulation results are offered to confirm the capability of the extended multilevel converter. After we solved the problem through calculation and analysis, a code was written in MATLAB with the aim that this time the code will tell us for what values of DC sources we will have the largest number of levels and as we expected, the output of the MATLAB code confirmed the correctness of the calculations.
Optimized IMC with GWO algorithm and variable switching function for voltage regulation of SEPIC converter Reza Fazeli; Mohammad Haddad Zarif; Mahmoud Zadehbagheri; Tole Sutikno
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 24, No 1: February 2026
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v24i1.27330

Abstract

With the growing application of single-ended primary-inductor converter (SEPIC) converters in power electronic systems, precise output voltage regulation under uncertainties and nonlinear conditions remains a significant challenge. Although internal model control (IMC) effectively addresses issues arising from unstable zeros and fixed time delays in non-minimum phase systems, its performance can degrade under large transient errors or sudden disturbances, leading to control signal saturation and instability. In this study, a modified IMC scheme is proposed, which integrates a variable switching function into the control structure. This addition enhances the robustness of the system by dynamically adapting the control effort to mitigate abrupt changes in the control signal and stabilize the output voltage. Furthermore, it prevents controller saturation during large-signal deviations, thereby improving transient response and maintaining system stability. The design parameters of the controller are optimized using the gray wolf algorithm to achieve an optimal balance between voltage overshoot, settling time, and closed-loop stability. Simulation results under various operating conditions confirm the superior performance of the proposed control method compared to conventional IMC.