The effect of short circuit fault on one winding to other windings in FRA N. F. M. Yasid; M. F. M. Yousof; R. Abd. Rahman; H. Zainuddin; S. A. Ghani
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 10, No 2: June 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (396.17 KB) | DOI: 10.11591/ijpeds.v10.i2.pp585-593

Abstract

Monitoring and diagnosis of power transformer in power systems have been examined and debated significantly in last few decades. Recently, more researchers have expressed their interest in these issues as the utilities and network operators operating under a rising cost-effecting pressure. Especially, in studying to monitor winding faults which is found to be the most common fault within transformers. This paper addresses the issue of the effect of inter-windings short circuit fault in a Dyn11 connected transformer. The specific aim is to study the effect of fault at winding of other phases to the response of measured phase. Frequency Response Analysis (FRA) which is discovered to be a powerful and sensitive method to examine and evaluate the condition, including the mechanical reliability of the transformer windings is used.
Frequency response analysis for transformer tap changer damage detection S. Al-Ameri; A. A. Alawady; M. F. M. Yousof; H. Ahmad; Ali. A. Salem; M. A. Talib
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 11, No 1: March 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (485.03 KB) | DOI: 10.11591/ijpeds.v11.i1.pp350-358

Abstract

Frequency response analysis (FRA) method has been proven to detect the transformer winding damage. However, there is no practical study which investigates the damages on transformer tap changer even though it has a high failure rate. Hence, this paper investigates normal and faulty transformer tap changer using FRA. The FRA measurements conducted using four different test configurations. Also, normal tap changer, pitting and coking tap changer contact were investigated. In addition to FRA measurement, winding resistance measurement has been conducted. The transformer turn ratio measurement also conducted to identify the taps positions. This study results significant to understand the effect of pitting and coking tap changer on the transformer frequency response. The results showed that pitting has a slight influence on the frequency response. However, coking shows a huge variation in low-frequency response. This effect observed during the winding resistance measurement.
Interpretation of sweep frequency response analysis traces on inter-turn short circuit fault Nurul Farahwahida Md Yasid; A. A. Alawady; M. F. M. Yousof; S. Al-Ameri; M. S. Kamarudin
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 11, No 1: March 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (376.791 KB) | DOI: 10.11591/ijpeds.v11.i1.pp309-316

Abstract

Sweep frequency response analysis (SFRA) is a reliable method for detection and diagnosis of faults in the active part of transformers. However, although SFRA is widely employed, the interpretation of SFRA signature is still a challenge and require experts to analyse them. This is due to lack of guideline and standard for SFRA signature interpretation and clarification. This paper presents the interpretation of SFRA signature by classification and quantification on inter-turn short circuit fault on the transformer winding. The short-circuited turns fault on HV winding phase “A” was practically simulated on three different units of three-phase transformers. The results of simulated fault are presented and discussed. A conclusion was drawn which provides the interpretation of the SFRA response due to inter-turn short circuit fault case by using a statistical indicator which is NCEPRI algorithm.
Phase to phase fault detection of 3-phase induction motor using FRA technique A. A. Alawady; M. F. M. Yousof; N. Azis; M. A. Talib
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 11, No 3: September 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (717.896 KB) | DOI: 10.11591/ijpeds.v11.i3.pp1241-1248

Abstract

The purpose for preparing this paper is to innovate a new method to detection and diagnosis the three-phase induction motor electrical failures, especially the failures that occur in Stator winding. Stator winding breakdown largely contributes to induction motor failures. To understand internal fault in induction motors winding, four cases studies of different three-phase induction motors (TPIM) were analysed according to two conditions: normal winding condition and windings shorted between two phases. In this paper, the measurement of frequency response analysis (FRA) on the stator winding with inter-phase short is presented. Additionally, Frequency Response Analysis (FRA) interpretation technique classify and quantify the fault is also proposed. For interpretation of the FRA, a statistical indicator, which is NCEPRI algorithm is used for comparison the measured responses.
The effect of short circuit fault in three-phase core-typed transformer N. F. M. Yasid; A. A. Alawady; M. F. M. Yousof; M. A. Talib; M. S. Kamarudin
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 11, No 1: March 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (494.404 KB) | DOI: 10.11591/ijpeds.v11.i1.pp409-416

Abstract

Different techniques for monitoring the transformer condition are continuously discussed. This is due to the fact that transformers are one of the most expensive components in the power system network. Not to mention the cost to fix any failure occurred in the transformer that have becoming more expensive nowadays. Frequency response analysis (FRA) is found to be the best method to monitor the transformer reliability. This paper presents a continuation of study presented in previous paper [1]. The study performed a laboratory test to show that the response of a normal winding phase A can be affected by short circuit fault which occurred at LV winding phase a, b, and c. To further investigate, current paper performed FRA measurement and applied fault on all phases. The same procedure is repeated on a distribution transformer to verify the findings. This is to examine the effect of fault at winding of other phases to the response of measured phase.
Frequency response analysis technique for induction motor short circuit faults detection A. A. Alawady; M. F. M. Yousof; N. Azis; M. A. Talib
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 11, No 3: September 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (640.754 KB) | DOI: 10.11591/ijpeds.v11.i3.pp1653-1659

Abstract

The paper presents the description for diagnostic methods of induction motor's stator windings fault. The presented methods use Frequency Response Analysis (FRA) technique for detection of Winding Faults in Induction Motor . This method is previously reliable method for faults diagnosis and detection in many parts of transformers including transformer windings. In this paper, this method was used for motor windings faults detection. This paper presents the FRA response interpretation on internal short circuit (SC) fault at stator winding on three cases studies of different three-phase induction motors (TPIM), were analysed according to two status: healthy induction motor at normal winding status and same motor with windings shorted of main windings. A conclusion of this paper provides the interpretation of and validation the FRA response due to internal SC fault case by using NCEPRI algorithm, which is considered as one of certified statistical indicators. The proposed method in this paper had a useful result for detect and diagnosis of stator windings faults of TPIM. The applications of developed method can be used to detece the other machines types faults.
Conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia H. M. Luqman; M. N. R. Baharom; N. A. M. Jamail; N. A. Othman; R. Abd. Rahman; M. F. M. Yousof; Irshad Ullah
Bulletin of Electrical Engineering and Informatics Vol 9, No 1: February 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (517.533 KB) | DOI: 10.11591/eei.v9i1.1863

Abstract

This paper presents conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia. Increasing industrialization and population growth around the world demands higher electricity supply. Power generation has yet to decline but transmitting sufficient electricity to consumers is worrisome due to scarce land space occupied by rapid urbanization. Hence reconductoring method was chosen to improve existing 132 kV overhead transmission line in Malaysia. A group of selected conductors were chosen for comparison where the high temperature low sag conductor stood out the most producing up to 40% sag reduction. This paper focuses on providing conductor alternatives to improve maximum sag of lowest conductor to ground for 132 kV transmission line in Malaysia in accordance to her climate and geographical factor.