N. A. M. Jamail
Universiti Tun Hussein Onn Malaysia

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia H. M. Luqman; M. N. R. Baharom; N. A. M. Jamail; N. A. Othman; R. Abd. Rahman; M. F. M. Yousof; Irshad Ullah
Bulletin of Electrical Engineering and Informatics Vol 9, No 1: February 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (517.533 KB) | DOI: 10.11591/eei.v9i1.1863

Abstract

This paper presents conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia. Increasing industrialization and population growth around the world demands higher electricity supply. Power generation has yet to decline but transmitting sufficient electricity to consumers is worrisome due to scarce land space occupied by rapid urbanization. Hence reconductoring method was chosen to improve existing 132 kV overhead transmission line in Malaysia. A group of selected conductors were chosen for comparison where the high temperature low sag conductor stood out the most producing up to 40% sag reduction. This paper focuses on providing conductor alternatives to improve maximum sag of lowest conductor to ground for 132 kV transmission line in Malaysia in accordance to her climate and geographical factor.
Space Charge and Electric Field Analysis on Contaminated XLPE Insulator M.H.A. Wahab; N. A. M. Jamail; E. Sulaiman; Q.E. Kamarudin; N.A. Othman; S.M.N.S. Othman
Indonesian Journal of Electrical Engineering and Computer Science Vol 12, No 1: October 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v12.i1.pp370-377

Abstract

Nowadays, XLPE cable has been widely used because it has better resistance than other cables. XLPE insulation has unique features including a high dielectric strength and high insulation resistance. A lot of researches based on hardware and software have been conducted to prove the effectiveness of XLPE cable such as AC and DC applications and Space Charge Distribution measurement under HVDC at High Temperature. This research focused on analysis of space charge and electric field on XLPE cable with effect of non-uniform contamination layer by using Quickfield Software. Non-uniform contaminations have been applied along XLPE cable using Arsenic Tribromide (AsBr3), Boron Bromide (BBr3), Ethylene Dichloride (CH2C1), Formic Acid (CH1O2), Formamide (CH3NO) and Alcohol element. Presence of these contamination elements represent of underground contamination. The size and layer of the contamination were non-uniform type. From the results, it is shown that lower dielectric constant of contamination will affect more on charge of XLPE insulation. As a conclusion, it can be seen lower dielectric constant value of contamination element greatly affecting the performance of XLPE insulation. Furthermore, size of contamination also influences the content of charge in contamination where the bigger the contamination size, the more charge contained in the contamination.