Renuga Verayiah
Universiti Tenaga Nasional

Published : 4 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Indonesian Journal of Electrical Engineering and Computer Science

A Comparison Study on Types of PV for Grid Connected Photovoltaic Power Renuga Verayiah; Anusiya Iyadurai
Indonesian Journal of Electrical Engineering and Computer Science Vol 6, No 2: May 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v6.i2.pp349-356

Abstract

Grid connected photovoltaic (PV) power systems is today’s breakthrough for renewable energy source in electricity generation Grid-connected photovoltaic (PV) power systems have the advantage of more effective utilization for highest renewable source of electricity generation and tendency to continual growth in the next years. The output performance grid connected photovoltaic (PV) power systems is influenced by the impact of cell temperature or ambient temperature and solar irradiance of the solar module. This paper highlights the effect of output energy of solar module by implementing different types of solar module technology and selecting the highest energy output of the module technology for modelling and simulating the design of grid connected photovoltaic (PV) power system using Matlab/Simulink.
Comparison of Weak Load Bus Detection using LQP_LT Index with PV and QV Analysis of PSS/E Renuga Verayiah; Azah Mohamed
Indonesian Journal of Electrical Engineering and Computer Science Vol 12, No 2: November 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v12.i2.pp577-584

Abstract

Identification of weak load buses which contributes to voltage instability problem is crucial in order for an appropriate mitigation action to be executed. The current power system transmission is not only stressed to deliver high load demand at the receiving end but also facing new challenges brought by the penetratrion of renewable energy sources. This new scenario requires power system operation and analysis to be robust and fast in detecting the accurate weak load bus for correction action. Due to this, many online indices to detect weak load bus during power system contingency have been developed. Nevertheless, LQP_LT is of the latest index developed which ultimately has the reactive power tracing capability for weak load bus detection and generate priority ranking list of the weak load buses. This index was tested on IEEE 14 bus test system for different contingency scenarios. The results obtained from the LQP_LT index is compared and validated with the PV and QV analyses obtained using industrial graded PSS/E software. It was concluded that the LQP_LT index is found to be robust, efficient and need less computation time as compared to the execution of voltage stability analysis using the PSS/E Tool.