Arlita Sariningrum
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search
Journal : Hemera Zoa

PF-32 Radiography Assessment of Femoral Muscle and Bone Density in Rats as Response to Biodegradable Iron (Fe) Porous Implants Arlita Sariningrum; Mokhamad Fakhrul Ulum; Sri Estuningsih; Deni Noviana
Hemera Zoa Proceedings of the 20th FAVA & the 15th KIVNAS PDHI 2018
Publisher : Hemera Zoa

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (566.324 KB)

Abstract

Iron (Fe) is considered as one group of metals that can be used as degradable metal implants (Schinhammer et al. 2010). Previous implantation studies have used porous Fe which purposes to increase the rate of degradation (Daud and Hermawan 2013). Changes in the condition of metal implants due to degradation and peri-implant muscle tissue reactions in the body can be observed using radiographic modality (Noviana et al. 2013). The aim of this study was to assess the radiographic density of implants, peri-implants and peri-implants-muscle as a response to Fe porous implants on the femur of the rats.