Claim Missing Document
Check
Articles

Found 4 Documents
Search
Journal : Journal of The Civil Engineering Student

Perbandingan Kuat Tekan Dinding Tanpa Plesteran dengan Plesteran Trassram Akibat Pengaruh Perendaman Air Tawar, Air Payau dan Air Asin Muhammad Fujii Hanafi; Muttaqin Muttaqin; Yunita Idris
Journal of The Civil Engineering Student Vol 1, No 2 (2019): Volume 1, Nomor 2, Agustus 2019
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Bata merah pada dinding memiliki struktur berpori yang berpotensi meresapnya air sehingga dinding menjadi lembab. Akibatnya adalah adanya perubahan warna cat, pengelupasan cat dan plesteran serta tumbuhnya jamur. Benda uji yang digunakan pada penelitian ini yaitu dinding tanpa plesteran berukuran (800×500×100) mm dan dinding plesteran trassram berukuran (800×500×130) mm dengan variasi perendaman yaitu perendaman air tawar, air payau dan air asin. Perendaman dilakukan sepertiga dari tinggi dinding. Benda uji dinding tanpa perendaman adalah benda uji dinding kontrol. Benda uji dinding dilakukan pengujian kuat tekan setelah benda uji dinding berumur 28 hari perawatan dan 21 hari perendaman. Pada dinding tanpa plesteran dengan perendaman air tawar, air payau dan air asin, nilai kuat tekan dinding mengalami penurunan sebesar 27,68%, 31,44% dan 37,24% dari dinding kontrol. Pada dinding plesteran trassram dengan perendaman air tawar, air payau dan air asin, nilai kuat tekan dinding mengalami penurunan sebesar 3,64%, 26,58% dan 35,47% dari dinding kontrol. 
Analisis Kuat Lentur Beton Agregat Daur Ulang Dengan Komposisi 35%; 50% dan 100% Maskura Sadila; Surya Bermansyah; Yunita Idris
Journal of The Civil Engineering Student Vol 1, No 2 (2019): Volume 1, Nomor 2, Agustus 2019
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penggunaan beton yang cukup besar untuk proses pembangunan mengakibatkan berkurangnya sumber daya alam yang digunakan sebagai bahan campuran beton. Salah satu cara pelestarian lingkungan dalam bidang konstruksi ialah dengan menggunakan agregat beton daur ulang (recycle concrete aggregate) sehingga dapat meminimalisir penggunaan agregat natural. Penelitian ini menggunakan beton daur ulang mutu K175, dengan ukuran pecahan/hancuran maksimum 31,5 mm. Mutu rencana kuat tekan adalah K300, pengujian kuat tarik lentur dilakukan pada balok 53x15x15 cm3, yang diuji pada umur 7, 14 dan 28 hari. Varian komposisi beton agregat daur ulang adalah 35%, 50% dan 100% terhadap agregat alam. Benda uji balok dilengkapi dengan satu peralatan ukur deformasi (transducer) yang terdiri dari pengukur deformasi vertikal yang disambungkan dengan data logger. Hasil yang diperoleh dari penelitian ini adalah nilai kuat tarik lentur beton agregat daur ulang lebih rendah daripada beton tanpa agregat daur ulang. Penurunan minimum terlihat pada varian komposisi 35% yaitu sebesar 4% (10%). 
Identification of Natural Frequency and Damping Ratio using Mikrotremor on Evacuation Building Ulee Lheue and Alue Deah Teungoh Teuku Nanta Setia; Mochammad Afifuddin; Yunita Idris
Journal of The Civil Engineering Student Vol 2, No 2 (2020): Volume 2, Nomor 2, Agustus 2020
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Dynamic of structure is parameter robustness building to dynamic load. That include natural frequency, and damping ratio. Dynamical structure characteristic analysis is done at escape building Ulee Lheue and escape building Alue Deah Teungoh using mikrotremor data record. The objectives are to find out the natural frequency of the building and ground beneath, and damping ratio of building. Horizontal to Vertical Spectral Ratio (HVSR) is use to process the ground data, , Floor Spectral Ratio (FSR) and Random Decrement Method (RDM) is use to process the building data. The results of ground natural frequency (f0) Alue Deah Teungoh is 4,571 Hz, and Ulee Lheue is 5,022 Hz. Natural frequency (f0) escape building Alue Deah Teungoh is 1,461 – 2,443 Hz, and escape buiding Ulee Lheue is 1,430 – 4,168 Hz. Damping ratio escape building Alue Deah Teungoh is 2,000 – 4,496 %, Damping ratio escape building Alue Deah Teungoh is 2,973 – 4,831 %.
Pengaruh Substitusi Campuran Abu Ampas Tebu dan Abu Sekam Padi sebagai Pengganti Semen terhadap Kuat Tekan Beton Mutu Tinggi pada Lingkungan yang Berbeda Nadya Rayyana; Mochammad Afifuddin; Yunita Idris
Journal of The Civil Engineering Student Vol 1, No 1 (2019): Volume 1, Nomor 1, April 2019
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pemanfaatan abu ampas tebu dan abu sekam padi sebagai pengganti semen dapat menjadi alternatif terbaik untuk mengatasi masalah lingkungan dikarenakan ampas tebu dan abu sekam padi merupakan salah satu sumber ampas terbanyak yang terdapat di Indonesia. Hal ini dikarenakan kedua ampas tersebut mengandung Silika (SiO2) sebagai salah satu unsur yang terkandung dalam semen. Tujuan utama penelitian ini adalah untuk mengetahui pengaruh lingkungan terhadap kuat tekan beton dengan penggunaan campuran abu ampas tebu dan abu sekam padi sebagai substitusi semen pada lingkungan yang terlindung, tidak terlindung, dan tertimbun tanah.  Material yang digunakan dalam penelitian ini adalah semen Portland, agregat halus, agregat kasar, air, superplasticizer, campuran abu ampas tebu dan abu sekam padi sebagai substitusi semen dengan variasi 0%, 5%, 10%, dan 15% dari volume semen.  Hasil penelitian ini menunjukkan bahwa perbedaan lingkungan perawatan berpengaruh terhadap kuat tekan beton mutu tinggi. Hasil pengujian kuat tekan beton mutu tinggi paling optimum pada umur 28 hari dan 56 hari yaitu pada persentase 5% yang mengalami peningkatan sebesar 40,76% dan 45,41% pada lingkungan terlindung.