Claim Missing Document
Check
Articles

Found 4 Documents
Search

Electrocardiogram abnormality and Distance Covered during Six Minute Walk Test on Diabetes Mellitus Type 2 Ni Made Elva Mayasari; Adhi Permana; Yudi Fadilah; Namira Amanda
Qanun Medika - Jurnal Kedokteran FK UMSurabaya Vol 4, No 2 (2020)
Publisher : Universitas Muhammadiyah Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30651/jqm.v4i2.3598

Abstract

AbstractDiabetes Mellitus (DM) is a metabolic disease that has the characteristics of hyperglycemia that occurs due to abnormalities of insulin secretion, insulin action, or both. Macrovascular complications are often also referred to as secondary atherosclerosis due to DM, which can cause cerebral vascular disease, coronary arterial disease, and peripheral atrial disease. Diagnostic tools are needed for early detection in cardiovascular diseases which is accurate, inexpensive, comfortable, and available in almost health center. One of the diagnostic tools for early detection of cardiovascular diseases is an electrocardiogram (ECG). Six Minute Walk Test (SMWT) is a simple, objective, inexpensive, and efficient test to assess functional capacity and prognosis. This study aims to [nmem1] see whether there is a correlation between abnormalities of ECG and distance covered during SMWT in DM patients. This study was a cross-sectional study design from DM patients in the Polyclinic of the Muhammadiyah Hospital in Palembang. Forty patients with type 2 DM who fulfilled inclusion and exclusion criteria were selected using a consecutive sampling method. Twenty-seven patients have abnormal ECG, and only thirteen patients had distance covered during SMWT >300m. There is a correlation between abnormalities of ECG and distance covered during SMWT in DM patients with a significance value p = 0.011.Keywords: Diabetes Mellitus type 2, Eelectrocardiogram, Six Minute WalkingCorrespondence author: elva.maya@yahoo.com  
Simulasi Penggunaan Komponen Smart Building untuk Meningkatkan IKE di Gedung Rektorat Universitas Udayana Adhi Permana; Rukmi Sari Hartati; I Nyoman Satya Kumara
Jurnal Teknologi Elektro Vol 21 No 2 (2022): (Juli - Desember) Majalah Ilmiah Teknologi Elektro
Publisher : Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/MITE.2022.v21i02.P11

Abstract

One of the important aspects in energy management is energy audit activities. he benefits of an energy audit include recommendations for actions to be taken to improve energy efficiency, reduce costs and save money on energy bills. This study aims to obtain information on the efficiency of the use of electrical energy in the rectorate building of Udayana University and how big the potential for saving electrical energy is through testing energy-saving equipment. The results of the measurement, observation and data collection of the load at the Udayana University rectorate, the total power and electrical energy consumption of the Udayana University Rectorate building are 120.12 kW and 15521.02 kWh, respectively. The biggest need for electricity supply is air conditioning, which is 61.5 kW with energy consumption of 62%. In general, the Rectorate building of Udayana University has an IKE value of 49.43 kWh/m2/year. The IKE value for the AC/non-AC building category is 4.12 kWh/m2/month (very efficient). Meanwhile, in terms of IKE per room, there is still a value below the efficient category because electrical equipment is still / left on when working hours are over, especially lights and air conditioners. The application of Smart Building equipment with the aim of efficient use of electrical energy shows a decrease in lighting electrical energy consumption by 161.25 kWh (31%) while for air conditioning by 143.86 kWh (11%).
IMPLEMENTASI KEBIJAKAN PERATURAN PEMERINTAH NOMOR 11 TAHUN 2017 TENTANG MANAJEMEN PEGAWAI NEGERI SIPIL DI BADAN KEPEGAWAIAN DAN PENGEMBANGAN SUMBER DAYA MANUSIA KOTA PALEMBANG M.Nanda Seftian; Meli Meli; Desi Fransiska; Sherly Feronita; Adhi Permana
Jurnal Ilmu Administrasi dan Studi Kebijakan (JIASK) مجلد 5 عدد 2 (2023): Jurnal Ilmu Administrasi dan Studi Kebijakan (JIASK) (Maret 2023)
Publisher : MAP Program Pascasarjana Universitas Sjakhyakirti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.48093/jiask.v5i2.140

Abstract

Fokus penelitian ini yaitu mengenai implementasi kebijakan Peraturan Pemerintah nomor 11 tahun 2017 tentang manajemen aparat sipil negara di Badan Kepegawaian dan Pengembangan Sumber Daya Manusia Kota Palembang. Ada dua sumber data dalam penelitian ini yaitu data primer dan data sekunder. Data primer yaitu data yang dikumpulkan dari sejumlah keterangan atau fakta-fakta yang secara langsung diperoleh dari penelitian lapangan dan langsung dari sumber data lapangan seperti hasil wawancara dan observasi di lokasi penelitian. Teknik pengumpulan data dalam penelitian ini yaitu observasi, wawancara dan dokumentasi. Teknik penentuan informan yang digunakan adalah purposive sampling. Teknik analisis data dalam penelitian ini yaitu reduksi data, penyajian data, dan penarikan kesimpulan. Implementasi Kebijakan Peraturan Pemerintah Nomor 11 tahun 2017 Tentang Manajemen Pegawai Negeri Sipil Pada Badan Kepegawaian dan Pengembangan Sumber Daya Manusia Kota Palembang dari hasil penelitian dan pembahasan dapat disimpulkan secara umum cukup berhasil karena sebagian besar Implementasi Kebijakan Peraturan Pemerintah Nomor 11 tahun 2017 Pada Badan Kepegawaian dan Pengembangan Sumber Daya Manusia Kota Palembang dapat diimplementasikan atau dilaksanakan
Simulasi Penggunaan Komponen Smart Building untuk Meningkatkan IKE di Gedung Rektorat Universitas Udayana Adhi Permana; Rukmi Sari Hartati; I Nyoman Satya Kumara
Jurnal Teknologi Elektro Vol 21 No 2 (2022): (Juli - Desember) Majalah Ilmiah Teknologi Elektro
Publisher : Program Studi Magister Teknik Elektro Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/MITE.2022.v21i02.P11

Abstract

Salah satu aspek penting dalam manajemen energi adalah kegiatan audit energi. Manfaat audit energi yaitu diperoleh rekomendasi tindakan yang harus diambil untuk meningkatkan efisiensi energi, mengurangi biaya dan menghemat uang pada tagihan energi. Penelitian ini bertujuan untuk memperoleh informasi efisiensi penggunaan energi listrik di gedung rektorat Universitas Udayana serta seberapa besar potensi penghematan energi listrik melalui pengujian peralatan hemat energi. Hasil dari pengukuran, pengamatan dan pendataan beban di rektorat Universitas Udayana, total daya dan konsumsi energi listrik gedung Rektorat Universitas Udayana sebesar 120,12 kW dan 15521,02 kWh. Kebutuhan penyediaan daya listrik terbesar adalah pada pengkondisian udara yaitu 61.5 kW dengan konsumsi energi sebesar 62%. Secara umum gedung Rektorat Universitas Udayana memiliki nilai IKE sebesar 49.43 kWh/ m2/ tahun. Untuk nilai IKE dengan kategori gedung AC/ non AC sebesar 4.12 kWh/ m2/ bulan (sangat efisien). Sedangkan dari sisi IKE per ruangan masih terdapat nilai dibawah kategori efisien yang disebabkan peralatan listrik masih/dibiarkan menyala saat jam kerja sudah berakhir terutama lampu dan AC. Penerapan peralatan Smart Building dengan tujuan pengefisiensian penggunaan energi listrik memperlihatkan terjadinya penurunan konsumsi energi listrik pencahayaan sebesar 161,25 kWh (31%) sedangkan untuk pengkondisian udara sebesar 143,86 kWh (11%).