Long Distance Dual SpO2 Monitoring System for Premature Babies Using Bluetooth Communication Priyambada Cahya Nugraha; Muhammad Ridha Mak'ruf; Lusiana; Sari Luthfiyah; Wahyu Caesarendra
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.7

Abstract

Monitoring the baby's health status is very important, especially for babies born prematurely. Oxygen saturation levels in newborns are very important to know because when the oxygen saturation levels in newborns are low, it is necessary to watch out for hemodynamic abnormalities in the baby. Measurement of oxygen saturation levels in newborns can help detect congenital abnormalities in infants early. This study aims to design an equipment system to continuously monitor the condition of oxygen saturation in newborns. Where in this discussion a monitoring tool is used to monitor 2 premature babies in a baby incubator simultaneously using a Neonatal Fingertip sensor. The system will display the oxygen saturation (SpO2) value and signal. Monitoring on this tool is done wirelessly using the HC-05. Based on the results of tests and measurements in 5 different patients with a pulse oximeter comparison, the difference value of 1% in each patient's results was obtained. The results of this study will greatly help facilitate the work of paramedics in monitoring the vital conditions of newborn babies.
Comparison of Air Pressure Control Between Discrete and PID Control Applied in the Calibration Process in Blood Pressure Meter Harisha Avin Nurcahyana; Tri Bowo Indrato; Triana Rahmawati; Wahyu Caesarendra
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 2 (2022): April
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v4i2.6

Abstract

In performing the calibration of the sphygmomanometer, the officer needs to first reset the installation and pump the bulb slowly until it reaches the set point in accordance with the calibration settings where this does not provide convenience to the calibration officer. So the author wants to do research on making additional devices to support DPM calibration instruments that have been commercialized to speed up the pump process in Sphygmomanometer calibration. The purpose of this research is to make an Automatic Pump module with PID control to analyze the stability of the pressure achievement in accordance with the set point when using the smoothing program or not. This study used set points of 50, 100, 150, 200, and 250 mmHg. Data retrieval was carried out within 260 seconds at each set point at the Campus of the Department of Electrical Engineering Poltekkes Kemenkes Surabaya. The results of this study indicate that the tool testing using the smoothing program experienced small oscillations compared to the program without smoothing. The data obtained are at setting 50 the average overshoot is 54 and the average undershoot is 49; at setting 100 the average overshoot is 109 and the average undershoot is 99; at setting 150 the average overshoot is 156 and the average undershoot is 149; at setting 200 the average overshoot is 206 and the average undershoot is 196; at setting 250 the average overshoot is 253 and the average undershoot is 247. The importance of this device was made in order to make it easier and faster for the calibration officer to calibrate the Sphygmomanometer.