Dian Anggraini
Pusat Teknologi Bahan Bakar Nuklir (PTBBN), BATAN Kawasan Puspiptek-Tangerang Selatan 15314, Banten

Published : 9 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 9 Documents
Search

Studi sensitasi baja tahan karat tipe 316 sebagai bahan kelongsong dan struktur fast breeder reactors Maman Kartaman A.; Rosika Kriswarini; Dian Anggraini
Jurnal Teknologi Bahan Nuklir Vol 11, No 1 (2015): Januari 2015
Publisher : PTBN - BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (272.534 KB)

Abstract

Abstract Sensitization study of type-316 stainless steell as cladding and structure of fast breeder reactor. Stainless steel was used in nuclear industry as cladding of Liquid Metal Fast Breeder Reactor (LMFBR), which operation temperature above 500 0C. According to the theory, resistance of stainless steel type 316 is good enough, but in the high temperature tend to influence by intergranular corrosion. The sensitization degree of Stainless Steel type 316 ( SS 316 ) was calculated by potentiostat using potentiodynamic method, and was observed by scanning electron microscope ( SEM ). The objective of this research was to analized the effect of heat treatment on corrosion resistance. First, samples were heat treated at 1,000°C for 3 hours and then were quenched in the water for 30 minutes. Samples were heat treated for 6 hours on the temperature : 350, 450, 550, and 650°C. The heat treated samples were corrosion tested by Potensiostat model M 273 with Potensiodynamic method. The surface of samples were observed by scanning Electron Microscope. Three kinds of SS 316 samples : Blank, solution treatment, and ageing for 650oC  were characterized by X – ray diffractor. The result showed that the corrosion rates increased with the increasing temperature. The corrosion rate of samples heat treated at 550 and 650°C were 105,9 and 118.37 mpy, the samples were heat treated at 350 and 450 °C after solution treatment did not exhibit intergranular, corrosion rate respectively were 89,39 and 91,06 mpy. The corrosion rates of samples that were heat treated at 550°C and 650°C without solution treatment, revealed were higher than with solution treatment. Keywords : inter granular corrosion, austenitic stainless steel type of 316, sensitization Abstrak Studi sensitasi baja tahan karat tipe 316 sebagai bahan kelongsong dan struktur fast breeder reactors. Dalam industri nuklir, baja tahan karat, paduan alumunium dan zirkaloy digunakan sebagai komponen pendukung reaktor riset atau daya dalam bentuk tangki bertekanan, pipa, kelongsong, bahan struktur dan lain – lain. Baja tahan karat tipe 316 dan 316L digunakan sebagai kelongsong bahan bakar LMFBR dimana temperatur operasinya bisa mencapai sekitar 500 0C. Temperatur operasi yang tinggi akan mengakibatkan fenomena sensitasi, yaitu fenomena dimana baja tahan karat menjadi rentan terhadap serangan korosi terutama korosi batas butir. Oleh karena itu dilakukan penelitian untuk mengetahui sejauh mana pengaruh panas terhadap ketahanan korosinya. Sampel SS 316 terlebih dahulu diberi perlakuan panas dari suhu 350 hingga 650 0C, selanjutnya diuji korosi menggunakan metode potensiodinamik. Hasilnya menunjukkan bahwa laju korosi sampel SS 316 yang telah dilaku panas yaitu solution treatment pada suhu 1000 0C dan diikuti artificial aging pada suhu 350, 450, 550 dan 650 0C berturut-turut adalah 56,59 mpy, 89,39 mpy, 91,06 mpy ; 105,9 mpy dan 118,37 mpy. Semakin tinggi suhu aging terlihat laju korosinya semakin tinggi. Pada mikrograf sampel SS 316 yang diamati menggunakan mikroskop elektron (SEM) menunjukkan telah terjadi korosi yang cukup signifikan pada bahan yang telah di aging pada suhu 550 dan 6500C. Pola difraksi untuk sampel SS 316 yang dilaku panas solution treatment dan diiukuti aging suhu 650oC menunjukkan terjadi perubahan fasa yaitu fasa kedua atau senyawa intermetalik yang menyebabkan laju korosi sampel SS 316 menjadi relatif tinggi. Kata Kunci : korosi batas butir, baja tahan karat SS 316, sensitasi
Penentuan burn up mutlak pelat elmen bakar U3Si2-Al tingkat muat uranium 2,96 gU/cm3pasca iradiasi Aslina Br.Ginting; Yanlinastuti .; Noviarty .; Boybul .; Arif Nugroho; Dian Anggraini; Rosika Kriswarini
Jurnal Teknologi Bahan Nuklir Vol 11, No 2 (2015): Juni 2015
Publisher : PTBN - BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (198.196 KB)

Abstract

Abstract Absolut burn-up determination of U3Si2-Al irradiated fuel plate with loading 2.96 gU/cm3. Absolute burn up measurement of U3Si2-Al irradiated fuel element with loading of 2.96 gU/cm3with  RI-SIE 2 code has been done. The burn up calculation of U3Si2-Al irradiated fuel element is based on the content of 137 Cs, 235U and 239 Pu isotopes which is obtained by radiochemical analysis after an appropriate separation. The purpose of the separation a monitoring of the fission product (137 Cs isotope) and the heavy elements (uranium and plutonium) is to get the  amount  of  235U isotope accurately.Separation and analysis of 137Cs isotope had been done by cation exchange using zeolit Lampung and spectrometre-g. While the separation both of isotop 235U and 239Pu had been done by anion exchange column using Dowex 1 x 8 resin. The efluen of U in the column anion exchanger was eluted by using HNO3 8N and the efluent of Pu was eluted by HCl 0.1N + HF 0.036N. Both of isotopes were analyzed by using a spectrometre-a. The analysis result showed that the content of 137Cs isotope in U3Si2-Al irradiated fuel element was 0.000716 g/g sample, while the content of 235U, 239 Pu and 238 Pu were 0.032824 g/g sample, 0.000011g/g sample and 0.000005 g/g sample respectively. The result of measurement 235U isotope compared with initially content of isotop 235U (fabrication data) for being used in the absolute burn up measurement. The result of absolute burn up calculation of U3Si2-Al irradiated fuel U3Si2-Al with loading of 2.96 gU/cm3with RI-SIE 2 code was 51.69 %.   Keyword : Separation and analysis of isotopes (Cs, U, Pu), cation and anion exchange, U3Si2-Al irradiated fuel element, burn up.. Abstrak Penentuan burn up mutlak  pelat elemen bakar U3Si2-Al tingkat muat uranium  2,96 gU/cm3pasca iradiasi. Telah dilakukan perhitungan burn up mutlak bahan bakar PEB U3Si2-Al tingkat muat uranium (TMU) 2,96 gU/cm3 pasca iradiasi dengan kode RI-SIE 2. Perhitungan dilakukan melalui hasilpemisahan dan analisis isotop 137Cs isotop,235U,dan Pu di dalam PEB U3Si2-Al pasca iradiasi secara radiokimia. Tujuan pemisahan isotop hasil fisi khususnya isotop 137Cs dengan  unsur heavy element (uranium dan plutonium) adalah untuk mendapatkan kandungan isotop 235U sisa (tidak terbakar) secara akurat. Pemungutan isotop 137Cs dilakukan dengan metode penukar kation menggunakan zeolit Lampung dan analisisnya menggunakan spektrometer-g, sedangkan pemungutan isotop 235U dan 239Pu dilakukan dengan metode kolom penukar anion menggunakan resin Dowex 1x8. Efluen U di dalam kolom dielusi menggunakan HNO3 8N dan efluen Pu dielusi dengan HCl 0,1N+HF 0,036N dan dianalisis menggunakan spektrometer-α.Hasil analisis menunjukkan bahwa kandungan isotop 137Cs di dalam PEB U3Si2-Al pasca iradiasi diperoleh sebesar 0,000716 g/g sampel, sedangkan kandungan isotop U dan Pu diperoleh masing-masing sebesar235U= 0,032824 g/g sampel, 239Pu= 0,000011g/g sampel dan 238Pu=0,000005 g/g sampel. Kandungan isotop 235U hasil pengukuran selanjutnya dibandingkan dengan kandungan isotop 235U mula-mula (data pabrikasi) untuk digunakan dalam perhitungan burn up mutlak. Hasil perhitungan burn up mutlak bahan bakar PEB U3Si2-Al TMU 2,96 gU/cm3 pasca iradiasi dengan kode RI-SIE 2 diperoleh sebesar 51,69 %.   Kata kunci : Pemisahan dan analisis isotop (Cs, U, Pu), penukar kation dan anion, PEB U3Si2-Al pasca  iradiasi, burn up.
PENGARUH APLIKASI METODA STANDAR INTERNAL PADA PENENTUAN UNSUR Cr DAN Ni DALAM ZIRKALOY 2 DENGAN METODA SPEKTROMETRI EMISI Dian Anggraini; Yusuf Nampira; Djoko Kisworo
Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol 15, No 2 (2009): April 2009
Publisher : website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (256.871 KB) | DOI: 10.17146/urania.2009.15.2.2592

Abstract

ABSTRAK Pengaruh aplikasi metoda standar internal pada dalam penentuan unsur Cr dan Ni dalam Zirkaloy 2 telah dilakukan dengan metoda Spektrometer Emisi. Tujuan dari kegiatan ini adalah untuk mengetahui pengaruh penggunaan metoda internal standar terhadap akurasi hasil analisis. Kegiatan analisis  dilakukan dengan menggunakan alat Spektrometer Emisi PV 30  dan  untuk mendapatkan kurva kalibrasi digunakan bahan standar paduan Zirkonium CRM JAERI variasi konsentrasi. Hasil evaluasi kurva kalibrasi menunjukkan bahwa koefisien regresi unsur Cr dan Ni menggunakan metoda standar internal lebih tinggi  dibanding dengan metoda absolut. Nilai koefisien regresi unsur Cr  pada daerah kerja 0,041 - 0,15 % diperoleh sebesar 98,55 % dengan menggunakan metoda absolut dan menjadi 99,21%  pada penggunaan metoda standar internal. Untuk unsur Ni, pada rentang daerah kerja 0,021 - 0,094 % diperoleh nilai regresi sebesar  93,11 % menggunakan metoda absolute dan bila menggunakan metoda standar internal menjadi 98,55 %. Konsentrasi  Cr dalam bahan paduan Zirkaloy 2 menggunakan metoda absolut dan standar internal masing- masing diperoleh sebesar sebesar 0,1035 % dan 0,1081%. Berdasarkan uji t 0,5 kedua nilai tersebut menunjukkan perbedaan yang signifikan. Data ini membuktikan bahwa analisis menggunakan  metoda standar internal dapat menghasilkan data yang lebih akurat dari pada metoda absolut. Untuk unsur Ni, data yang diperoleh tidak dapat dievaluasi secara kuantitatif  karena intensitas pengukuran berada di luar daerah kerja pengukuran Ni.   Kata Kunci : Analisis Unsur (Cr,Ni),  zirkaloy 2, spektrometer emisi dan  Metoda Standar Internal     ABSTRACT The influence of application of standard internal method in the deter-mination of elements   Cr and Ni in ZirCaloy 2 has been done by  Emission Spectrometer technique. The objective of the analysis is to study the influence of internal standard method to the accuracy of the analytical result. This analysis has been done by using of emission spectrometer using Zirconium standard material CRM JAERI of various concentration to obtain calibration curves. the Evaluation of calibration curves indicate that the element regression coefficient of Cr and Ni by standard internal method is inclining in comparison to that by absolute method. The regression coefficient of Cr obtained at working area of 0.041 – 0.15% is 98.55% by using absolute method and 99.21% by standard internal method. The regression coefficient of Ni obtained at working area between 0.021 – 0.094% is 93.11% by absolute method and 98.55% by standard internal method. The concentration of Cr in Zirkaloy 2 obtained by standard internal and absolute method is similar in value, i.e. 0.1035% and 0.1081% respectively. Based on test t 0.5 however, both the concentration value for both methods has difference significantly. This fact proves that the analysis using standard internal method can yield more accurate data than that of absolute method. The data obtained for Ni cannot be evaluated quantitatively because the measurement intensity in the experiment was beyond the measurement working area of Ni.   Key Word : Elemental analysis Cr, Ni, zirkaloy 2 , emission spectrometer,   standard and Internal Method.
PENENTUAN KANDUNGAN Sn, Fe, Cr, Ni DAN PENGOTOR ZIRCALOY-2 SEBAGAI BAHAN KELONGSONG DAN TUTUP UJUNG ELEMEN BAKAR REAKTOR DAYA Arif Nugroho; Dian Anggraini; Rosika K; Djoko Kisworo
Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol 14, No 4 (2008): Oktober 2008
Publisher : website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (299.737 KB) | DOI: 10.17146/urania.2008.14.4.2570

Abstract

ABSTRAK PENENTUAN KANDUNGAN Sn, Fe, Cr, Ni DAN PENGOTOR ZIRCALOY-2 SEBAGAI BAHAN KELONGSONG DAN TUTUP UJUNG ELEMEN BAKAR REAKTOR DAYA. Telah dilakukan pengukuran unsur  pemadu dan pengotor dalam zircaloy-2 menggunakan alat spektrometer emisi dan X-Ray Flouresence (XRF). Tujuan penelitian ini adalah memverifikasi spesifikasi bahan zircaloy-2 (Zry-2) yang digunakan secara kualitatif dan kuantitatif. Langkah pertama yang dilakukan adalah seluruh permukaan bahan sampel standar dan sampel zircaloy-2 dihaluskan menggunakan mesin bubut, dan dibersihkan menggunakan alkohol. Sampel yang sudah bersih dan kering diukur menggunakan alat spektrometer emisi dan XRF dengan tujuh kali pengulangan. Pengukuran bahan standar dengan berbagai variasi konsentrasi unsur digunakan untuk membuat kurva kalibrasi hubungan antara konsentrasi unsur dengan intensitas. Hasil pengukuran intensitas unsur dalam sampel zircaloy-2 kemudian diplotkan ke kurva kalibrasi sehingga konsentrasi unsur dalam sampel zircaloy-2 dapat diketahui. Hasil penelitian ini diharapkan dapat dipakai sebagai metode analisis pengukuran zircaloy-2, karena alat spektrometer emisi dan XRF selektif untuk mengukur unsur-unsur logam dalam suatu bahan. Hasil pengukuran unsur pemadu dalam sampel zircaloy-2 adalah Sn 1,346%, Fe 0,2151%, Cr 0,12 % dan Ni 0,039%. Sedangkan kandungan unsur pengotor Al 42,7275 ppm, Cu 6,0335 ppm, Si 54,0706 ppm, Ti 39,9182 ppm, Co, Mn dan Mo tidak terdeteksi. Hasil analisis unsur yang diperoleh masih dalam kisaran nilai sertifikat zircaloy-2 sehingga zircaloy-2 dapat digunakan sebagai bahan kelongsong sesuai yang dipersyaratkan fabrikasi. Konsentrasi pengotor lainnya seperti B, C, Ca, Cd, Hf, H, Mg, N, Na, Nb, Pb, Ta, U, V, W dan O belum bisa ditentukan, karena keterbatasan bahan standar dan detektor yang digunakan pada alat spektrometer emisi. Kata kunci : Zircaloy-2, metode spektrometri emisi dan X-ray fluorescence (XRF)   ABSTRACT Determination of Sn, Fe, Cr, Ni and Zr-2 impurities as cladding material and end cup of fuel element for power reactor. A measurement of major and poison elements in zircaloy-2 using emission spectrometer and X-Ray Fluorescence (XRF) equipment has been conducted. The objective of this investigation is for verifying specification of zircaloy-2 material by qualitative and quantitative method. Firstly, the surface of standards and a Zr-2 sample were smoothed by lathe equipment, and cleaned by using alcohol. The clean and dry samples were measured by emission spectrometer and XRF equipment seven times. The measurement of standard elements with different concentrations was carried out to prepare calibration curves of element concentrations versus intensity. Hence, the element intensities of zircaloy-2 sample were plotted to calibration curve so that the concentration can be found. The result of measurement is expected to be used as zircaloy-2 measurement analysis method, since emission spectrometer and XRF equipment are selective for measuring metal element in the materials. The results obtained were Sn 1.346%, Fe 0.2151%, Cr 0.12 % and Ni 0.039%, whilst the impurities were  Al 42.7275 ppm, Cu 6.0335 ppm, Si 54.0706 ppm, Ti 39.9182 ppm, and Co, Mn and Mo were not detected. The result analysis showed that the specification of Zr-2 sample is still in the limit so that it can be used as a cladding material. The other impurities such as  B, C, Ca, Cd, Hf, H, Mg, N, Na, Nb, Pb, Ta, U, V, W and O could not measured because the standard materials and the detectors  are not available in place. Key words: Zircaloy-2, emission spectrometry method and X-ray fluorescence (XRF).
FENOMENA KOROSI ZIRKALOY-2 DAN ZIRKALOY-4 DALAM MEDIA LARUTAN NaCl SECARA ELEKTROKIMIA Dian Anggraini; Maman Kartaman Ajiriyanto; Rosika Kriswarini; Yanlinastuti Yanlinastuti
Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol 21, No 3 (2015): Oktober 2015
Publisher : website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (580.019 KB) | DOI: 10.17146/urania.2015.21.3.2465

Abstract

ABSTRAKFENOMENA KOROSI ZIRKALOY-2 DAN ZIRKALOY-4 DALAM MEDIA LARUTAN NaCl SECARA ELEKTROKIMIA. Zirkaloy-2 dan zirkaloy-4 digunakan sebagai bahan kelongsong pada elemen bahan bakar reaktor daya BWR (Boiling Water Reactor) dan PWR (Pressurized Water Reactor). Selama penggunaanya dalam kolam penyimpanan bahan bakar bekas kemungkinan kelongsong berinteraksi dengan air laut (sea water), dalam hal kondisi abnormal. Ion klorida yang terdapat dalam air laut memiliki potensi penyebab terjadinya korosi pada bahan kelongsong. Tujuan penelitian ini adalah untuk mengetahui fenomena korosi zirkaloy-2 dan zirkaloy-4 dalam media NaCl melalui penentuan parameter korosi dengan teknik tahanan polarisasi, Tafel dan potensiodinamik. Sampel berupa potongan bahan zirkaloy-2 dan zirkaloy-4 dengan dimensi 1x1 cm dilakukan proses mounting dan disolder dengan kawat tembaga, kemudian permukaan sampel dipoles menggunakan amplas 1200 grit. Uji korosi dilakukan dalam sel korosi yang dilengkapi dengan elektrode standar (saturated calomel), elektroda penyangga (grafit) dan elektroda kerja (sampel). Media pelarut yang digunakan adalah larutan NaCl dengan konsentrasi 3,5  %; 0,35 % dan 0,175 %. Hasil penelitian menunjukkan bahwa adanya ion Clˉ pada daerah konsentrasi NaCl 0,175 % sampai dengan 3,5 % tidak mempengaruhi pola mekanisme korosi. Jenis korosi pada daerah potensial ± 250 mV terhadap Ecorr adalah korosi merata dalam bentuk oksida ZrO2. Laju korosi zirkaloy-2 dan zirkaloy-4 pada konsentrasi NaCl 3,5 % diperoleh masing-masing sebesar 6,39×10-3 dan 7,40×10-3 mpy. Fenomena korosi yang diamati dengan teknik potensiodinamik (± 1000 mV terhadap Ecorr) menunjukkan bahwa zirkaloy-2 dan zirkaloy-4 mengalami pasivasi dan korosi pitting. Potensial pitting zirkaloy-2 dan zirkaloy-4 diperoleh masing- masing sebesar -452,8 mV dan -182,8 mV.Kata kunci: Korosi, zirkaloy-2 dan zirkaloy-4, media larutan NaCl, elektrokimia, teknik polarisasi ABSTRACTCORROSION PHENOMENA OF ZIRKALOY-2 AND ZIRKALOY-4 IN NaCl SOLUTION MEDIUM BY ELECTROCHEMICALLY. Zircaloy-2 and zircaloy-4 are used as cladding material in Light Water Reactor, (LWR), Boiling Water Reactor (BWR) and Pressurezid Water Reactor (PWR). During its use in the spent fuel pool may interact between the cladding and seawater in case of abnormal condition. Chloride ion which contained in seawater has the potential for being corrosion in cladding material. The aim of this work was knowing zircaloy-2 and zircaloy-4 corrosion phenomena in NaCl medium by corrosion parameter determination with polarization resistance technique, tafel, and potentiodynamic. Samples are zircaloy-2 and zircaloy-4 pieces material with 1x1 cm dimension. The samples are mounting and soldered with copper wire, then the sample surface are polished by 1200 grade grinding paper. Corrosion test was done with corrosion cell that was completed by electrode standard (saturated calomel), electrode buffer (grafit) and work electrode (sample). Solvent medium was NaCl solution with concentration 3.5 %; 0.35 %; and 0.175 %. The result showed that ion Clˉ contained in NaCl which were concentration area from 0.175 % to 3.5 % did not affect corrosion mechanism. The corrosion type in potential range ± 250 mV to E­­corr was uniform corrosion in ZrO­2 oxide form. Zirkaloy-2 and zirkaloy-4 corrosion rate in 3.5 % NaCl concentration were obtained 6.39×10-3 and 7.40×10-3 mpy respectively. Corrosion phenomenon which was observed by potentiodynamic technique (± 1000 mV to Ecorr) showed that zirkaloy-2 and zirkaloy-4 underwent passivation and pitting corrosion. Pitting potential zirkaloy-2 and zirkaloy-4 were obtained -452.8 mV and -182.8 mV severally.Keywords: Corrosion, zirkaloy-2 and zirkaloy-4, NaCl solvent medium, electrochemical, polarization technique.
PERBANDINGAN METODA OTOMATIS DAN MANUAL DALAM PENENTUAN ISOTOP Cs-137 MENGGUNAKAN SPEKTROMETER GAMMA Rosika Kriswarini; Dian Anggraini
Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol 15, No 2 (2009): April 2009
Publisher : website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (347.59 KB) | DOI: 10.17146/urania.2009.15.2.2593

Abstract

Abstrak Perbandingan metoda otomatis dan metoda manual dalam penentuan isotop Cr-137  menggunakan Spektrometer-GAMMA. Analisis isotop bahan radioaktif biasanya dilakukan menggunakan Spektrometer Gamma. Dalam pengoperasiannya, alat tersebut menggunakan metoda yang sudah terpasang pada alat tersebut (metoda otomatis). Selain metoda tersebut juga digunakan metoda menggunakan kurva kalibrasi (metoda manual). Tujuan dari kegiatan ini adalah untuk mengetahui pengaruh kedua teknik tersebut terhadap akurasi dan presisi pengukuran isotop Cs-137. Penentuan isotop Cs-137 dilakukan berdasarkan kalibrasi spektrometer-γ menggunakan sumber standar Europium (Eu-152), Cobalt (Co-60), dan Cesium (Cs-137) yang dilakukan pada energi 3 kV dengan waktu cacah 500 detik. Akurasi penentuan isotop Cs-137 menggunakan standar Eu-152, Co-60 dan gabungan Cs-137 dan Co-60 dengan metoda otomatis berturut-turut adalah 99,92%, 99,93%, dan 99,94%. Akurasi penentuan Cs-137 menggunakan standar Eu-152, Co-60, dan gabungan Co-60 dan Cs-137 dengan metoda manual adalah 99,99%, 99,90%, dan 99,88%. Hasil perhitungan uji beda metoda manual dan otomatis menunjukkan bahwa presisi kedua metoda tersebut dapat diterima pada tingkat kepercayaan 95%. Kata Kunci : Metoda otomatis dan manual, isotop Cs 137 dan  spektrometer Gamma. Abstract The comparison of automatic and manual methods analysis in determining Cs-137 isotope using GAMMA-Spectrometer. The Analysis of radioactive isotopes commonly used by Gamma Spectrometer. That   are installed automatically  in the apparatus. Beside that are, it used calibration curve in manual method. The purpose of this experiment is to know the precision and accuracy of both methods in determining Cs-137 isotope. The determination of Cs-137 isotope was based of γ-Spectrometer calibration using Europium (Eu-152), Cobalt (Co-60) and Cesium (Cs-137) standard source in 3 kV of operation energy and 500 seconds counting time. The measurement accuracy of Cs-137 isotope determination by means of Eu-152, Co-60 and combination of Cs-137 and Co-60 standard using automatic method respectively are 99,92%, 99,93%, and 99,94%, whereas using manual method are 99,99%, 99,90%, and 99,88%. The difference test of statistic analysis (F-test) showed that the range precision value of manual method and automatic method lie on the 95% confidence level. Keyword : Otomatic and manual method, Cs-137 isotop and  Gamma spectrometer.
ANALISIS KOROSI PADUAN AlMg2 DAN AlMgSi MENGGUNAKAN METODE ELEKTROKIMIA Dian Anggraini; Maman Kartaman; Rosika Kriswarini; Yanlinastuti .
Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol 20, No 3 (2014): Oktober 2014
Publisher : website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (381.479 KB) | DOI: 10.17146/urania.2014.20.3.2390

Abstract

ABSTRAK ANALISIS KOROSI PADUAN AlMg2 DAN AlMgSi MENGGUNAKAN METODE ELEKTROKIMIA. Analisis korosi terhadap bahan kelongsong dan struktur bahan bakar reaktor riset, AlMg2 dan AlMgSi telah dilakukan dalam media air demineral pH 6,7 dan pH 2 menggunakan metode elektrokimia. Proses korosi suatu bahan logam dipengaruhi oleh beberapa faktor, diantaranya adalah komposisi kimia dan kondisi media pelarut. Tujuan kegiatan ini adalah untuk mengetahui fenomena korosi AlMg2 dan AlMgSi melalui penentuan parameter korosi secara kuantitatif dan kurva polarisasi potensiodinamik dalam media netral ( pH 6,7) dan asam (pH 2). Bahan yang digunakan berupa paduan AlMg2 dan AlMgSi dengan bentuk circular dish dan luas 1cm . Preparasi sampel uji dilakukan dengan mengikuti prosedur ASTM G3 yaitu grinding, pembersihan dan pengeringan. Metode elektrokimia yang dilakukan pada penelitian ini mencakup pengukuran open circuit potensial (OCP), tahanan polarisasi dan potensiodinamik dalam media air demineral pada pH 2 dan pH 6,7 pada suhu 25 C. Hasil pengukuran OCP diperoleh nilai potensial korosi (Ecorr) paduan AlMg2 dan AlMgSi masing – masing sebesar - 906,1 mV dan -619,8 mV pada pH 2 dan -868,6 mV dan -756,7 mV pada pH 6,7. Hasil pengukuran tahanan korosi menunjukkan laju korosi AlMg2 lebih rendah dari pada AlMgSi baik pada pH 2 maupun pH 6,7. Laju korosi AlMg2 dan AlMgSi pada pH 2 lebih besar dari padaa pH 6,7 tetapi masih berada dalam daerah aman (< 20 mpy). Kurva potensiodinamik menunjukkan bahwa passifasi pada pH 6,7 masih relatif rendah sedangkan pada pH 2 terjadi pasivasi dalam kisaran potensial yang relatif pendek dan diikuti peristiwa terkorosi.   Kata Kunci : analisis korosi, metode elektrokimia, AlMg2 dan AlMgSi   ABSTRACT CORROSION ANALYSIS OF AlMg2 AND AlMgSi USING ELCTROCHEMICALL METHOD. Corrosion test of cladding materials and structures of research reactor fuel, AlMgSi and AlMg2 have been performed in demineralized water of pH 2 and 6.7 using an electrochemical method. Corrosion fenomena is affected by several factor such as composition and condition of solution. The purpose of this activity is to investigate the corrosion phenomena through the determination of the parameters of corrosion and polarization curve. The materials used are AlMg2 and AlMgSi alloy in circular dish shape with an area of 1 Cm . Preparation of the test sample is performed through several stages polishing, cleaning and drying procedures followed ASTM G3. The electrochemical method is done by measuring the open circuit potential (OCP), polarization resistance and potentiodynamic in demineralized water of pH 2 and pH 6.7 at temperature of 25 C. The results of the OCP is the corrosion potential (Ecorr) of AlMg2 and AlMgSi each of -906.1 mV and -619.8 mV at pH 2 and -868.6 and -756.7 mV at pH 6.7 mV. The results of measurements by polarization resistance technique showed that the corrosion rate of AlMg2 and AlMgSi in safe category (<2mpy) at pH 6.7 and at pH 2 corrosion rate increased significantly, but still in the lightweight category (<20 mpy). Potentiodynamic curves showed that the passivation at pH 6.7 is very low while the passivation at pH 2 occurs within a relatively short range potential and followed events corroded. Keyword: corrosion analysis, metode elektrokimi, AlMg2, AlMgSi.
PEMBUATAN ISOTOP 137Cs SEBAGAI SUMBER RADIASI GAMMA UNTUK DIGUNAKAN DALAM INDUSTRI Aslina Br.Ginting; Dian Anggraini; Arif Nugroho; Rosika Kriswarini; Gatot Wurdiyanto; Hermawan .
Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol 20, No 3 (2014): Oktober 2014
Publisher : website

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2014.20.3.2392

Abstract

ABSTRAK PEMBUATAN ISOTOPCs SEBAGAI SUMBER RADIASI GAMMA UNTUK DIGUNAKAN DALAM INDUSTRI. Dalam melakukan uji pasca iradiasi pelat elemen bakar (PEB) U3Si2-Al banyak larutan hasil pengujian bahan bakar nuklir yang disimpan di dalam hotcell dengan keaktifan yang sangat tinggi. Larutan tersebut mengandung isotop 137Cs, uranium serta transuranium yang mempunyai waktu paroh panjang dan berbahaya bagi lingkungan. Namun limbah hasil pengujian tersebut memiliki nilai ekonomis tinggi karena dapat dimanfaatkan sebagai   bahan baku untuk pembuatan sumber radiasi sinar gamma isotop  137Cs. Hal ini dapat membantu bidang industri dalam memenuhi kebutuhan sumber radioaktif dalam negeri karena selama ini  kebutuhan isotope 137Cs di Indonesia masih tergantung dari industri luar negeri. Selain itu, pengadaan dan transportasi isotope 137Cs dari luar negeri serta dalam penggunaannya memerlukan persyaratan yang cukup ketat karena harus mendapat izin persetujuan dari Badan Pengawas Tenaga Nuklir Nasional (BAPETEN), sehingga menyebabkan harga isotope 137Cs menjadi mahal sampai di Indonesia. Dengan alasan tersebut, BATAN sebagai lembaga litbang  nuklir di Indonesia perlu mempelajari pembuatan sumber radiasi gamma isotop  137Cs dari larutan hasil pengujian bahan bakar nuklir U3Si2-Al pasca iradiasi. Manfaat isotope 137Cs sangat luas antara lain digunakan dalam menganalisis sampel lingkungan, industri migas, konstruksi, radiografi, perikanan, rumah sakit dan pertambangan. Pembuatan sumber radiasi gamma isotope 137  Cs dimulai dari pengumpulan limbah hasil pengujian PEB U3Si2-Al. Limbah larutan hasil pengujian mengandung isotope 137Cs dan isotop lainnya dikumpulkan menjadi satu dalam botol yang tahan radiasi. Pemungutan isotope 137Cs dari hasil fisi lainnya dilakukan dengan metode penukar kation menggunakan zeolit Lampung. Hasil pemungutan diperoleh padatan 137Cs-zeolit dalam fasa padat dan isotop lainnya berada dalam fasa cair. Padatan 137Cs-zeolit kering kemudian kemudian ditimbang dan diukur aktivitasnya menggunakan spektrometer-. Untuk menjadi sumber radiasi gamma 137Cs, padatan  137Cs-zeolit akan dikemas dengan cara memasukkan ke dalam wadah tertutup (shield source) berbentuk kapsul dari stainless steel oleh PTKMR. ABSTRACTMANUFACTURING OF CS ISOTOP AS GAMMA SOURCE FOR USING IN INDUSTRY. In the post-irradiation examination of fuel element plate (PEB) U3Si2-Al), a solution of high activity as a result of testing nuclear fuel stored in hotcell with enough volume. The solution can not bediscarded as waste because it still contains fission isotopes such as 137Cs, uranium andtransuranium, which has a long half life and dangerous for the environment. This can help theindustry in order to fulfill the needs of a radioactive source in Indonesia, because until now  137Csisotope is derived from foreign industries. In addition, the procurement and transportation ofIsotopes 137Cs require stringent requirements, because they have to get permission from theNational Nuclear Energy Agency (BAPETEN), thus causing the price of high activity 137Cs isotopes becomes expensive to Indonesia. For these reasons, BATAN as nuclear R & D institutions in Indonesia need to study make isotopes 137Cs gamma radiation source, which is contained in the waste from spent fuel test results U3Si2-Al. Isotope C137s can be used very widely, such as in the analysis of environmental samples, the oil and gas industry, construction,radiography, fisheries, hospitals, and mining. Making isotope 137Cs gamma radiation sourcestarting from the collection of waste from the test results PEB U3Si2-Al. Waste solution was collected in a bottle that is resistant to radiation. Collection of 137Cs isotopes of other fission carried out using the method of cation exchange with zeolite Lampung. The results of separation are 137 Cs-zeolite in the solid phase and the other isotopes are in the liquid phase. 137Cs-zeolite solid is then dried and then weighed and measured its activity using a spectrometer-g.137Cs-zeolite solids then packed in sealed containers (shield source) capsule-shaped stainless steel by PTKMR. Keywords: process waste of PEB U3Si2-Al, gamma radioactive, isotope  zeolite Lampung and industry
PEMBUATAN SUMBER RADIASI GAMMA 137Cs DENGAN AKTIVITAS 20 mCi DARI PEB U3Si2-Al PASCA IRADIASI DALAM CONTAINER STAINLESS STEEL Aslina Br. Ginting; Yanlinastuti Yanlinastuti; Noviarty Noviarty; Boybul Boybul; Arif Nugroho; Dian Anggraini; Rosika Kriswarini; Sriyono Sriyono; Moch Subechi; Gatot Wurdiyanto; Hermawan Hermawan
Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol 21, No 3 (2015): Oktober 2015
Publisher : website

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2015.21.3.2463

Abstract

ABSTRAKPEMBUATAN SUMBER RADIASI GAMMA ISOTOP 137Cs DENGAN AKTIVITAS 20 mCi DARI PEB U3Si2-Al PASCA IRADIASI DALAM CONTAINER STAINLESS STEEL. Kegiatan uji pasca iradiasi pelat elemen bakar (PEB) U3Si2-Al banyak menghasilkan larutan dengan keaktifan yang sangat tinggi. Larutan tersebut mengandung isotop 137Cs, uranium serta transuranium yang mempunyai waktu paroh panjang dan berbahaya bagi lingkungan. Namun larutan tersebut memiliki nilai ekonomis tinggi karena dapat dimanfaatkan sebagai bahan baku untuk pembuatan sumber radiasi sinar gamma isotop 137Cs. Hal ini dapat membantu bidang industri dalam memenuhi kebutuhan sumber radioaktif dalam negeri karena selama ini kebutuhan isotop 137Cs di Indonesia masih tergantung dari industri luar negeri. Selain itu, pengadaan dan transportasi isotop 137Cs dari luar negeri serta dalam penggunaannya memerlukan persyaratan yang cukup ketat dari Badan Pengawas Tenaga Nuklir Nasional (BAPETEN), sehingga menyebabkan harga isotop 137Cs menjadi mahal sampai di Indonesia. Dengan alasan tersebut, BATAN sebagai lembaga litbang nuklir di Indonesia perlu mempelajari pembuatan sumber radiasi gamma isotop 137Cs dari larutan hasil pengujian bahan bakar nuklir U3Si2-Al pasca iradiasi. Manfaat isotop 137Cs sangat luas antara lain digunakan dalam menganalisis sampel lingkungan, industri migas, konstruksi, radiografi, perikanan, rumah sakit dan pertambangan. Pembuatan sumber radiasi gamma isotop 137Cs dimulai dari pengumpulan larutan hasil pengujian PEB U3Si2-Al. Larutan larutan hasil pengujian mengandung isotop 137Cs dan isotop lainnya dikumpulkan menjadi satu dalam botol dengan volume 65 mL. Pemisahan isotop 137Cs dari hasil fisi lainnya dilakukan dengan metode penukar kation menggunakan zeolit Lampung dengan berat 45 gr. Hasil pemisahan diperoleh 137Cs-zeolit dalam fasa padat dan isotop lainnya berada dalam fasa cair. Padatan137Cs-zeolit kering kemudian kemudian ditimbang dan diukur aktivitasnya menggunakan spektrometer-g. Hasil analisis dengan spektrometer-g diperoleh aktivitas padatan 137Cs-zeolit sebesar 20 mCi. Untuk menjadi sumber radiasi gamma 137Cs, padatan 137Cs-zeolit dengan aktivitas 20 mCi dikemas dengan cara memasukkan ke dalam inner-outer capsule terbuat dari stainless steel yang telah dirancang sebelumnya. Container stainless steel diproses menjadi sumber radiasi gamma tertutup (shield source) untuk selanjutnya disertifikasi oleh PTKMR-BATAN sebagai lembaga kalibtrator bahan radioaktif di BATAN.Kata kunci: Larutan proses PEB U3Si2-Al, radioaktif gamma, isotop 137Cs, penukar kation, zeolit Lampung dan container. ABSTRACTMANUCFACTURING OF 137Cs GAMMA RAY SOURCE WITH ACTIVITY 20 mCi FROM PEB U3Si2-Al POST IRRADIATION IN STAINLESS STEEL CONTAINER. In the post-irradiation examination of fuel element plate (PEB) U3Si2-Al), a solution of high activity as a result of testing nuclear fuel stored in hotcell with enough volume. The solution can not be discarded as waste because it still contains fission isotop such as137Cs, uranium and transuranium, which has a long half life and dangerous for the environment. This can help the industry in order to fulfill the needs of a radioactive source in Indonesia, because until now 137Cs isotope is derived from foreign industries. In addition, the procurement and transportation of isotopes 137Cs require stringent requirements, because they have toget permission from the National Nuclear Energy Agency (BAPETEN), thus causing the price of high activity 137Cs isotopes becomes expensive to Indonesia. For these reasons, BATAN as nuclear R&D institutions in Indonesia need to study make isotopes 137Cs gamma radiation source, which is contained in the waste from spent fuel test results U3Si2-Al. Isotope 137Cs can be used very widely, such as in the analysis of environmental samples, the oil and gas industry, construction, radiography, fisheries, hospitals, and mining. Making isotope 137Cs gamma radiation source starting from the collection of waste from the test results PEB U3Si2- Al. Waste solution was collected in a bottle with volume 65 mL. Collection of 137Cs isotopes of other fission carried out using the method of cation exchange with weight 45 gr of zeolite Lampung. The results of separation are 137Cs-zeolite in the solid phase and the other isotopes are in the liquid phase. 137Cs-zeolite solid is then dried and then weighed and measured its activity using a spectrometer-g. Result of analisys by spectrometer-g was obtained acitivity of 137Cs-zeolite solids was 20 mCi.137Cs-zeolite solids then packed in sealed containers (shield source) capsule-shaped stainless steel and than certificate by PTKMR-BATAN.Keywords: Process wastle of PEB U3Si2-Al, gamma radioactive, isotope 137Cs, cation exchange, zeolite Lampung and container.