Analysis of Digital Image Rejection (RFA) inDiagnosticRadiology Services after the Application of Computed Radiography (CR) to the Hospitals in Area Semarang City Gatot Murti Wibowo; Dwi Rochmayanti; M. Irwan Katili
Jurnal Riset Kesehatan Vol 2, No 1 (2013): Januari 2013
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (8055.191 KB) | DOI: 10.31983/jrk.v2i1.151

Abstract

The purpose of this study was to determine the rejection of digital image analysis procedure CR softcopy hereinafter referred to as RFA, and describe the profile and characteristics of the proportion image rejection (rejection rates) based on the operational conditions of CR.Quantitative research was conducted with the observational approach. Data were collected by random sampling from 1181 digital image system CR-1137 type 1 at A hospital and the total number of CR type 2 digital image at B hospital on the status of post-image processing. Profiles and characteristics of the CR-system rejection rate was 9.15% while the type 1 for type 2 CR-system is 4.57%. Largest percentage of CR image rejection on both failitas dominated by chest radiographic anatomy of the organ which is 69.44% (A) and 48.08% (B). The findings reject rates of 15.87% due to poor performance of x-ray equipment and distribution teridenfitikasinya reject rates based on radiographer in A hospital deserves special attention. Though the radiographer and the employment rate figures reject individually in “ A” hospital not correlated (0.67 more than p-value).
Acceptance Test Of Diagnostic X-Ray Merk GE Type XR 6000 In Radiodiagnostic And Radiotherapy Department Laboratory Of Health Polytechnic Of Semarang M. Irwan Katili; Andrey Nino Kurniawan; Nanang Sulaksono
Jurnal Riset Kesehatan Vol 3, No 1 (2014): Januari 2014
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (132.148 KB) | DOI: 10.31983/jrk.v3i1.236

Abstract

The purpose of this study is to test the X-ray equipment GE Type XR 6000 in in JTRR Laboratory of Health Polytechnic in Semarang the and analyze the test results. It is a quantitative measurement of some components including Collimator, X-ray tube and generator. The instruments used for the measurement were Piranha test tool, TOR ABC as well as the water passes. The measurement result for light is 281.67 lux, deviation for collimator ΔX + ΔY is 1.8% and a deviation of 1.5 degrees. For the measurement of tube leakage is still below the leak amounted to 1 mGy / h. The accuracy of all tubes is less than 5% (diff kVp). Tube current output is still appropriate with the setting. The linearity coefficient results in mAs linearity testing is less than 0.1. The CV value of reproducibility is ≤ 0.05. While the value of the measured HVL is already greater than 2.3 mmAl at 80 kVp. In conclusion, the results of the measurements of X-rays equipment Ge Type XR 6000 in JTRR Laboratory of Health Polytechnic of Semarang is still within the acceptance for use.
Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution Siti Daryati; M. Irwan Katili; Sri Mulyati
Jurnal Riset Kesehatan Vol 3, No 2 (2014): Mei 2014
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (753.192 KB) | DOI: 10.31983/jrk.v3i2.220

Abstract

This is an observational method with a quantitative approach to study the magnitude of dose area product who received ESWL patients and the level of safety in accordance with the rules of radiation safety in the use of X-ray. Processing and analysis of the data is done by calculating the dose area product ( DAP ) received by the patients at each exposure based on the thickness of the patients were detected with the TLD. Comparison is done with the use of standard flouroscopy examination. Result shows that 10 cm material thickness in 0.008 minutes results 187mGy.cm2 and 5095 mGy.cm2 DAP in 5 minutes. While in 20 cm phantom thickness and in 0.008 minutes result 424 mGy.cm2 and DAP obtained in 5 minutes is 2 20912 mGy.cm. The use of fluoroscopy on ESWL in Dr . Kariadi hospital is still within the safe limits: less than 100 mGy / min , the dose rate exposure on a 10 cm phantom thickness is 3.38 mGy / min and in 20 cm phantom thickness is 13.89 mGy / min , exposure dose rate per minute on the phantom thickness of the 23 cm is 17.03 mGy / min and the rate of patient exposure dose obtained by the observation of 17.61 mGy / min.
Attitude And Action Mother With Hiv Aids On Stigma And Discrimination People at Semarang City M. Irwan Katili; Rini Indrati; Yeti Kartikasari
Jurnal LINK Vol 8, No 1 (2012): Januari 2012
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat, Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (470.767 KB) | DOI: 10.31983/link.v8i1.173

Abstract

The purpose of this study to explore the attitudes and actions of mothers with HIV AIDS stigma and discrimination people in the city of Semarang. The research was conducted with a qualitative approach. As the population of mothers with HIV-AIDS is the number of 26 people, while the number of samples is 6 people for Mother PLWHA. To triangulate the source comes from a number of health personnel and the public a number of 3 people 6 people. The collection of data used interviews and Focus Group Discussions with the techniques Data Analysis used Interactive Models. The attitudes and actions of mothers living with HIV Stigma and discrimination against people is to avoid interacting with the community and need support from family, health professionals and peers (DKS)