PERBANDINGAN ALOKASI PENEMPATAN FILTER AKTIF DAN FILTER PASIF UNTUK MENDAPATKAN DISTORSI DAYA TERKECIL PADA JARINGAN DISTRIBUSI DI BLUE POINT BAY Auryn Herman Gautama; Antonius Ibi Weking; I Wayan Rinas
Jurnal SPEKTRUM Vol 7 No 2 (2020): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (675.477 KB) | DOI: 10.24843/SPEKTRUM.2020.v07.i02.p6

Abstract

Harmonic filter is a power electronics technology to produce specific current components that canbe used to reduce harmonic currents generated by non-linear loads. Non-linear load is usually foundon electronic equipment in which there are semi-conductor components, such as the use of airconditioners, TVs, computers, medical equipment, musical instruments and so forth. Based onpreliminary measurements at Blue Point Bay Villa & Spa, the simulation results of the THD (TotalHarmonic Distortion) current value of 25.17%, which means exceeding the IEEE 159-2014 standardvalue of ? 15.0%. Filters that are placed incorrectly can cause THD harmonics to be suboptimal. Fromthe results of the study it was found that the THDv value at Blue Point Bay Villa & Spa was 4.83%where these conditions met the maximum THDv IEEE 519-2014 standard for voltages ? 69 kV. THDivalue at Blue Point Bay Villa & Spa after the use of active and passive filters is ? 15% and accordingto IEEE Standard 519-2014. The best placement of active filters to reduce power distortion is SDP 2.2because it can reduce power distortion from 20.08% to 3.94%, and the best passive filter placement isMDP 2, because it can reduce power distortion from 20.13 % to 8.52%.
Simulasi Penentuan Penempatan Filter Aktif Shunt Untuk Mendapatkan Distorsi Daya Yang Terkecil Di Blue Point Bay Villa & Spa Antonius Ibi Weking; I Wayan Rinas; AK Suwardana
Jurnal Teknologi Elektro Vol 12 No 2 (2013): (July - December) Majalah Ilmiah Teknologi Elektro
Publisher : Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (233.325 KB)

Abstract

Pengoperasian beban-beban nonlinear dapat menimbulkan distorsi harmonisa dalam bentuk gelombang tegangan dan arus yang mengakibatkan kondisi sistem kelistrikan tidak normal. Blue Point Bay Villa & Spa memiliki kandungan harmonisa yang tidak sesuai dengan standar IEEE 519-1992. Kandungan THD (Total Harmonics Distortion) arus yang berlebih dapat menyebabkan kualitas daya sistem menjadi lebih buruk, sehingga menyebabkan faktor daya sistem menjadi lebih rendah. Filter aktif shunt berbasis inverter yang bertujuan untuk meredam harmonisa yang muncul. Dalam penelitian ini dilakukan simulasi penggunaan filter aktif menggunakan sofware simulink MATLAB, pengelompokkan jenis beban nonlinear, perhitungan daya aktif (P) dan arus beban (IL), simulasi pada sistem sebelum dan sesudah penggunaan filter aktif, analisis daya distorsi (D), analisis THD hasil simulasi sesuai dengan IEEE 519-1992 yang ditentukan dan analisis penempatan filter aktif shunt yang tepat untuk menekan distorsi daya. Hasil analisis menunjukkan pemasangan filter aktif menyebabkan kandungan THD arus dan tegangan telah sesuai dengan IEEE 519-1992 yang ditentukan. Daya distorsi harmonisa pada sistem mengalami penurunan dan terjadi peningkatan faktor daya mendekati unity power factor pada feeder. Penempatan filter aktif shunt yang baik untuk menurunkan THD dan distorsi daya yaitu pada SDP 2 MDP 2 yaitu 7.551,23 VA.
RANCANG BANGUN PEMODELAN PEMBANGKIT LISTRIK TENAGA MIKRO HIDRO (PLTMH) MENGGUNAKAN KINCIR OVERSHOT WHEEL I Wayan Budiarsana Saputra; Antonius Ibi Weking; Lie Jasa
Jurnal Teknologi Elektro Vol 16 No 2 (2017): (May - Agustus) Majalah Ilmiah Teknologi Elektro
Publisher : Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (370.21 KB) | DOI: 10.24843/MITE.2017.v16i02p09

Abstract

Ketergantungan pembangkit listrik terhadap sumber energi seperti minyak solar, gas alam dan batubara yang hampir mencapai 75%, mendorong dikembangkannya energi terbarukan sebagai upaya untuk memenuhi pasokan listrik. Pada penelitian ini telah dirancang pemodelan PLTMH menggunakan kincir overshot wheel dengan bentuk sudu setengah lingkaran, diameter kincir 50cm, dan 16 jumlah sudu. Pada pemodelan ini debit air 0,1 lt/s dan head 0,6 meter. Pengukuran yang dilakukan berdasarkan posisi jatuhnya air terhadap kincir, dari posisi sudut nozzle 00, 50, 100, 150, 200, 250, 300, 350 dan 400.
PERENCANAAN SISTEM KONTROL PENERANGAN DI VILLA ALILA TANAH LOT TABANAN BALI Antonius Ibi Weking
Jurnal Teknologi Elektro Vol 9, No 2 (2010): (July - December) Majalah Ilmiah Teknologi Elektro
Publisher : Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (216.201 KB)

Abstract

Penggunaan energi listrik merupakan suatu kebutuhan primer untuk seluruh lapisan masyarakat. Untukmenunjang perkembangan dari sarana penggunaan energi listrik harus dibuat handal, salah satunya dengankeamanan yang cukup tinggi dan dapat dipergunakan secara efektif serta efisien. Pada saat sekarang ini, PLN mulaimencanangkan program penghematan energi listrik.Dalam makalah ini akan dianalisis penggunaan sistem kontrol untuk penerangan pada Villa Allila Tanah Lot.,yang mana ditujukan untuk mendapatkan penghematan energi listrik yang tentunya tidak lepas dari kenyamananpengguna villa tersebut.Hasil analisis menunjukkan bahwa terjadi penghematan energi listrik pada penerangan sebesar 0.9296kWH/hari. Di dalam villa Alila Tanah Lot yang mempergunakan kontrol sensor gerak dan fitting sensor geraksebesar 0.0527 kWH/hari dan menghemat 9.36% dari energi listrik yang digunakan untuk penerangan di dalam villaAlila Tanah Lot. Sistem kontrol penerangan di luar villa Alila Tanah Lot dapat menghemat sebesar 0.8769kWH/hari dan menghemat 4 % dari energi listrik yang digunakan di luar villa Alila Tanah Lot.
PROTOTYPE DESIGN OF MICRO HYDRO USING TURBINE ARCHIMEDES SCREW FOR SIMULATION OF HIDROPOWER PRACTICAL OF ELECTRO ENGINEERING STUDENTS Antonius Ibi Weking; Yanu Prapto Sudarmojo
Journal of Electrical, Electronics and Informatics Vol 3 No 1 (2019): JEEI (February 2019)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2019.v03.i01.p02

Abstract

Development of new and renewable energy source always developed by world researchers which one of those is energy source from water, because it’s friendly for environment and low cost. Water is one of energy source which it’s have big potential in all Indonesian territory. The main problem from microhydropower plants is a water discharge which it’s flow is not continued every year because influenced by weather season. Micro Hydro is a microhydro power plants (MHP)in a small scale. A micro hydro can be operated in a certain of time if it has a enough water supply. To knowing a right of micro hydro’s characteristic is not easy thing to learn it. It is because a characteristic each of micro hydro’s installation location is considered specific location. One type of micro hydro is using Archimedes Screw Turbine. Udayana University of Electrical Engineering Department in this time not have a facility for hydropower field to use this model, so a college student not yet to receive a knowledge of this. Through this research, a writer want to expand a college student’s knowledge in hydropower field with create a prototype of micro hydro with Archimedes Screw Turbine to hydropower practical in laboratory. In this research the effect of screw’s height angle conversion and effect of water pressure conversion has to be researched. In this study will discuss the influence of water pressure and slope of the altitude angle on the rotation produced by the Archimedes screw turbine so that it can be seen the voltage, current, power generated by the generator, torque and efficiency . The result of from handmade equipment for this research in angle 40­0 with biggest generator round (rpm) is 3768 (rpm) and highest power is 10.92057 watt, torque adalah 0.60 Nm dan efisiensi sebesar 14 %. The torque which resulted from water pressure 24 psi is 0,73 Nm and efficience 18,01 %. The voltage, current, and output power which resulted in generator is 85,8 Volt, 0,1963 Ampere and 16,85 Watt. For generator speed round in the pressure 24 Psi is 4582 rpm, while turbine speed round which resulted from the pressure 24 Psi is 383 rpm before coupled with generator and 222 rpm after coupled with generator.
Simulasi Penentuan Penempatan Filter Aktif Shunt Untuk Mendapatkan Distorsi Daya Yang Terkecil Di Blue Point Bay Villa & Spa Antonius Ibi Weking; I Wayan Rinas; AK Suwardana
Jurnal Teknologi Elektro Vol 12 No 2 (2013): (July - December) Majalah Ilmiah Teknologi Elektro
Publisher : Program Studi Magister Teknik Elektro Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pengoperasian beban-beban nonlinear dapat menimbulkan distorsi harmonisa dalam bentuk gelombang tegangan dan arus yang mengakibatkan kondisi sistem kelistrikan tidak normal. Blue Point Bay Villa & Spa memiliki kandungan harmonisa yang tidak sesuai dengan standar IEEE 519-1992. Kandungan THD (Total Harmonics Distortion) arus yang berlebih dapat menyebabkan kualitas daya sistem menjadi lebih buruk, sehingga menyebabkan faktor daya sistem menjadi lebih rendah. Filter aktif shunt berbasis inverter yang bertujuan untuk meredam harmonisa yang muncul. Dalam penelitian ini dilakukan simulasi penggunaan filter aktif menggunakan sofware simulink MATLAB, pengelompokkan jenis beban nonlinear, perhitungan daya aktif (P) dan arus beban (IL), simulasi pada sistem sebelum dan sesudah penggunaan filter aktif, analisis daya distorsi (D), analisis THD hasil simulasi sesuai dengan IEEE 519-1992 yang ditentukan dan analisis penempatan filter aktif shunt yang tepat untuk menekan distorsi daya. Hasil analisis menunjukkan pemasangan filter aktif menyebabkan kandungan THD arus dan tegangan telah sesuai dengan IEEE 519-1992 yang ditentukan. Daya distorsi harmonisa pada sistem mengalami penurunan dan terjadi peningkatan faktor daya mendekati unity power factor pada feeder. Penempatan filter aktif shunt yang baik untuk menurunkan THD dan distorsi daya yaitu pada SDP 2 MDP 2 yaitu 7.551,23 VA.
PERENCANAAN SISTEM KONTROL PENERANGAN DI VILLA ALILA TANAH LOT TABANAN BALI Antonius Ibi Weking
Jurnal Teknologi Elektro Vol 9, No 2 (2010): (July - December) Majalah Ilmiah Teknologi Elektro
Publisher : Program Studi Magister Teknik Elektro Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penggunaan energi listrik merupakan suatu kebutuhan primer untuk seluruh lapisan masyarakat. Untukmenunjang perkembangan dari sarana penggunaan energi listrik harus dibuat handal, salah satunya dengankeamanan yang cukup tinggi dan dapat dipergunakan secara efektif serta efisien. Pada saat sekarang ini, PLN mulaimencanangkan program penghematan energi listrik.Dalam makalah ini akan dianalisis penggunaan sistem kontrol untuk penerangan pada Villa Allila Tanah Lot.,yang mana ditujukan untuk mendapatkan penghematan energi listrik yang tentunya tidak lepas dari kenyamananpengguna villa tersebut.Hasil analisis menunjukkan bahwa terjadi penghematan energi listrik pada penerangan sebesar 0.9296kWH/hari. Di dalam villa Alila Tanah Lot yang mempergunakan kontrol sensor gerak dan fitting sensor geraksebesar 0.0527 kWH/hari dan menghemat 9.36% dari energi listrik yang digunakan untuk penerangan di dalam villaAlila Tanah Lot. Sistem kontrol penerangan di luar villa Alila Tanah Lot dapat menghemat sebesar 0.8769kWH/hari dan menghemat 4 % dari energi listrik yang digunakan di luar villa Alila Tanah Lot.
RANCANG BANGUN PEMODELAN PEMBANGKIT LISTRIK TENAGA MIKRO HIDRO (PLTMH) MENGGUNAKAN KINCIR OVERSHOT WHEEL I Wayan Budiarsana Saputra; Antonius Ibi Weking; Lie Jasa
Jurnal Teknologi Elektro Vol 16 No 2 (2017): (May - Agustus) Majalah Ilmiah Teknologi Elektro
Publisher : Program Studi Magister Teknik Elektro Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/MITE.2017.v16i02p09

Abstract

Ketergantungan pembangkit listrik terhadap sumber energi seperti minyak solar, gas alam dan batubara yang hampir mencapai 75%, mendorong dikembangkannya energi terbarukan sebagai upaya untuk memenuhi pasokan listrik. Pada penelitian ini telah dirancang pemodelan PLTMH menggunakan kincir overshot wheel dengan bentuk sudu setengah lingkaran, diameter kincir 50cm, dan 16 jumlah sudu. Pada pemodelan ini debit air 0,1 lt/s dan head 0,6 meter. Pengukuran yang dilakukan berdasarkan posisi jatuhnya air terhadap kincir, dari posisi sudut nozzle 00, 50, 100, 150, 200, 250, 300, 350 dan 400.