Claim Missing Document
Check
Articles

Found 2 Documents
Search

Komparasi Performa Insulasi Termal Antara Dinding Batu Bata dan Batu Bata dengan Penambahan Insulasi Alang-Alang Niniek Pratiwi; Baharuddin Hamzah; Rosady Mulyadi
Jurnal Teknik Vol 18 No 1 (2020): Jurnal Teknik
Publisher : Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (504.618 KB) | DOI: 10.37031/jt.v18i1.60

Abstract

Buildings consume about 40% of the world's energy, beginning from the process of making the building itself to how the building could meet human thermal comfort needs. In the past, reeds were often used in traditional buildings, but unfortunately these days the practice is being abandoned. Several studies have shown that weeds can reduce building temperatures. However, these studies research has not examined how reeds are used as insulation material along with bricks so the purpose of this study is to compare the thermal insulation performance between plain brick and brick wall with the addition of reed insulation. The method used in this research is to use Ecotect simulation. Based on the results of simulations carried out it is known that model 1, namely the plain brick wall, has an outside-inside temperature difference of -1.32917 ° C. This means that the average temperature inside is hotter than the outside temperature by 1.32917 ° C. Meanwhile in model 2, the brick wall with the addition of reeds insulation has an outside-inside temperature difference of 0.445833 ° C. This means that the average temperature inside is cooler than the outside temperature by 0.445833 ° C. Therefore, it can be concluded that reeds could be used as thermal insulation material because it could store heat better than the material in Model 1, which is a plain brick wall.
Thermal Sensation Analysis in the Building of Universitas Ichsan Gorontalo Siti Khairunnisa Abay; Baharuddin Hamzah; Rosady Mulyadi
EPI International Journal of Engineering Vol 5 No 1 (2022): Volume 5 Number 1, February 2022
Publisher : Center of Techonolgy (COT), Engineering Faculty, Hasanuddin University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25042/epi-ije.022022.10

Abstract

Gorontalo City is characterized by a tropical climate, where thermal comfort is a crucial component to achieve, particularly for educational activities aimed at students. The thermal comfort is affected by various factors, namely building design, internal, and external factors. The university building represents a facility where face-to-face learning and teaching activities occur. The purpose of the current study is to analyze the perceived thermal comfort of students during classroom activities with three different air conditioning (AC) settings (16, 22, and 27 oC) in theUniversitas Ichsan Gorontalo campus building. This research employed a quantitative descriptive method, comprising thermal measurements inside the classroom and questionnaire distribution to students to collect thermal sensation data. The research object was conducted in three separate classrooms during the time range of 08.00-15.00 Central Indonesia time. The results revealed that most students felt neutral and comfortable in the three different AC settings inside the classroom. Nevertheless, it should be noted that thermal comfort could be influenced by other factors, such as physical activity and clothing. Consequently, further research could be conducted by taking into consideration these factors and engaging the participation of teachers and staff to acquire a more comprehensive understanding of thermal comfort in the campus building.