Pengukuran Laju Paparan Radiasi pada Perisai Radiasi Ruang Panoramik di Instalasi Radiologi Rumah Sakit Islam Klaten Raih Sutejo; Siti Daryati
Jurnal Imejing Diagnostik (JImeD) Vol 2, No 2: July 2016
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v2i2.3177

Abstract

Background: Research about the measurement of radiation exposure rate on panoramic radiation shield in Radiology Installation of Klaten Islamic Hospital has been conducted. The background of this research is in the panoramic room there is a veil that has a gap on the bottom as high as 20 cm. The purpose of this research is to know the rate of radiation exposure on radiation panoramic shield in Radiology Installation of Klaten Islamic Hospital and the application of radiation protection system to the room.Methods: This research type is quantitative with survey approach that is writer do observation, documentation and measurement of exposure rate of radiation at controlled and uncontrolled area by doing measurement at two state that is before exposure (background radiation) and after exposure. The data obtained are then analyzed descriptively to declare a safe examination room or not for workers and the general public by comparing the measurement results with UNSCEAR and NCRP report No. 147.Result: The value of the background exposure rate in the panoramic chamber of the Klaten Hospital Radiology Installation exceeds the value of the background dose rate based on the location of the height of an area according to UNSCEAR. The background exposure value in the panoramic space ranges from 0.14 to 0.175 μGy/hour. The actual radiation exposure measurements at point A is 0.00021 mGy/hour, point B is 0.000175 mGy/h, point C is 0 mGy/hour, point D is 0 mGy/hour, point E is 0.000105 mGy/hour, point G is 0,000735 mGy/hour. These six results have not exceeded the NCRP report no. 147 is for controlled areas 0.0025 mGy / hr and uncontrolled area 0.0005 mGy / hr.
Rancang Bangun Alat Bantu Fiksasi Pemeriksaan Radiografi Shoulder Joint Proyeksi Inferosuperior Axial Siti Daryati; Okta Firawan Putra Purwa; Dwi Rochmayanti
Jurnal Imejing Diagnostik (JImeD) Vol 2, No 1: January 2016
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v2i1.3166

Abstract

Backgroud: Have been done research about making of the design tools fixation on radiographic examination shoulder against the backdrop of the difficulty in positioning the patient to commit abduction. The purpose of the design is to replace the role of the patient's family or resident physician in charge of holding the cassette and the patient's arm in abduction during the examination takes place.Methods: This research is a quantitative with explorative experimental approach. The method used in data collection that is designing the tools, use tools, and test tools function. Test function tools made directly to the patient in the Radiology department of DR.Sardjito Yogyakarta. The results of test functions are analyzed based check list of respondents about the value of work tools.Results: The results of design tools fixation on radiographic examination shoulder joint inferosuperior axial projections in the form of iron under the buffer, the buffer on iron, steel main buffer, where handrail 1, where handrail 2 and the cassette place. The workings of the device is placed beside the examination table, abduction of the patient's arm and place it on a hand grip and place cassette on a the cassette place. The function test results on the assessment tool's ability to adjust to the state of the patient's arm, the ability of the tool settings when adjusting the tool height to the height of the examination table or brangkar, the ability of the tool settings when adjusting the length of the tool with the patient's arm length of, the ability of the tool setting in place the cassette on tools, the ability of setting tool in positioning the tape on the object of examination, the ability of the tool to produce radiographs that do not cause artifacts..Conclusion: the ability to show the joints between the glenoid cavity of the humeral head to 2.37. It can be concluded that the tools fixation radiographic examination of shoulder joint inferosuperior axial projection has a pretty good performance.