Optimization of Device Installations in the Home Solar Power Generation System Ignatius R Mardiyanto; Sri Paryanto Mursid; Sri - Utami
Jurnal Internasional Penelitian Teknologi Terapan Vol 3 No 2 (2022): October 2022
Publisher : Bandung State Polytechnic (Politeknik Negeri Bandung)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35313/ijatr.v3i2.80

Abstract

One of the main challenges in building a Solar Power Generation System at home or a Home Solar Power Plant (Home SPP) is choosing component specifications according to price. The main components of Home SPP are photovoltaics (PV) panels, inverters, and wiring systems. Given the strict price constraints, the selection of parts available on the commercial market is generally of low quality. However, low-quality components can still provide a significant advantage by optimizing the plant design. This research proves that the proper configuration can reduce electricity bills by 52.2%. This configuration does by choosing a Grid Tie Inverter (GTI) with a high working voltage and a 12 Volt PV configured in a parallel series circuit to work at 24 Volts. In addition, the 12 Volt PV panels configured in series to 24 Volts are proven to increase the conversion efficiency.
The Harmonics Effect of Variable Speed Drives on Generator Performance Mardiyanto, Ignatius Riyadi
Jurnal Internasional Penelitian Teknologi Terapan Vol 1 No 2 (2020): October 2020
Publisher : Bandung State Polytechnic (Politeknik Negeri Bandung)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35313/ijatr.v1i2.34

Abstract

Large motors often burden synchronous generators as power plants in factories. This motor is commonly using to regulate rotation using Variable Speed Drive (VSD). From the load side, VSD, as a regulator of motor rotation, can reduce power loss. On the generator side as a power plant, this load with VSD affects the waveform of the generator. The experiments on a small capacity generator (6 kVA) with a VSD as regulating the motor rotation with a load of about 1.1 kW shows effectiveness power transfer is about 40.7% with VSD, and without VSD, efficiency is approximately 39.6%. The motor losses by installing VSD interpreted as transferring losses to the generator with savings is about 1 %. The experiments also showed that generator performance decreases when loaded with VSD at around 6%, and a generator temperature increases at 20 0C higher than without VSD.