Pusparini Pusparini
Clinical Pathology Department, Faculty Of Medicine, Universitas Trisakti, Jakarta, Indonesia

Published : 8 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 8 Documents
Search

Correlation Between HbA1c and Albuminuria in Type 2 Diabetes Mellitus Jesika Merlin; Pusparini Pusparini
Majalah Kedokteran Bandung Vol 52, No 3 (2020)
Publisher : Faculty of Medicine, Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15395/mkb.v52n3.2013

Abstract

In patients with type 2 diabetes mellitus (Type 2 DM), glycemic control plays an essential role in reducing macro- and microvascular complications. The earliest marker for diabetic nephropathy is the presence of albuminuria. Meanwhile, HbA1c  has been recognized as a marker of glycemic control in the blood. This study aimed to identify the correlation between HbA1c and albuminuria in type 2 DM. This was a cross-sectional study involving 100 patients with type 2 DM aged 40–70 years visiting Dr. Soetomo Hospital, Surabaya, Indonesia. Secondary data from medical records of type 2 DM patients undergoing HbA1c and albuminuria examinations from January to December 2015 were used. The mean age of subjects was 55.4 ±8.7 years, with the majority (55%) being of female gender. The mean HbA1c concentration was 9.8±2.4%. Most subjects (83%) had an HbA1c level of ≥7 %. Albuminuria was found in the majority of the subjects (78%), where 33% of them had positive  1 albuminuria. The Spearman correlation test showed a positive strong significant correlation between HbA1c and albuminuria, with r=0.865 and p<0.001. Thus, it can be concluded that there is a significant correlation between HbA1c and albuminuria in type 2 DM.Korelasi HbA1c dan Albuminuria pada Diabetes Melitus Tipe 2 Pada penderita diabetes melitus tipe 2 (DM tipe 2), kontrol glikemik memegang peranan penting untuk menurunkan komplikasi makrovaskular dan mikrovaskular. Petanda awal terjadinya nefropati diabetik adalah adanya albuminuria. HBA1c merupakan petanda untuk mengetahui kontrol glikemik didalam darah. Tujuan penelitian ini untuk mengetahui korelasi antara HbA1c dengan albuminuria pada  DM tipe 2. Penelitian ini menggunakan desain potong lintang, mengikutsertakan 100 penderita DM tipe 2 berusia 40–70 tahun di Rumah Sakit Dr. Soetomo Surabaya. Data yang digunakan adalah data sekunder dari rekam medis penderita DM tipe 2 yang melakukan pemeriksaan HbA1c dan albuminuria pada bulan Januari 2015 sampai dengan Desember 2015. Rerata usia subjek adalah 55,47±8,7 tahun dengan subjek terbanyak berjenis kelamin perempuan (55%). Rerata kadar HbA1c berkisar 9,8±2,4 %. Sebagian besar subjek mempunyai kadar HbA1c ≥7 % yaitu 83%. Albuminuria dijumpai pada sebagian besar subjek yaitu 78% dan sebagian besar subjek mempunyai albuminuria positif 1, yaitu 33 %. Hasil uji korelasi Spearman menunjukkan terdapat korelasi positif kuat yang bermakna antara HbA1c dengan albuminuria dengan nilai r=0,865 dan p<0,001. Dengan demikian, dapat disimpulkan terdapat korelasi yang bermakna antara HbA1c dan albuminuria pada DM tipe 2.
Performance Comparison of Dymind DH-76 and Sysmex Xn-1000 Automated Hematology Analyzers Pusparini Pusparini; Alvina Alvina
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY Vol 28, No 3 (2022)
Publisher : Indonesian Association of Clinical Pathologist and Medical laboratory

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24293/ijcpml.v28i3.1907

Abstract

An automatic hematology analyzer is an essential instrument for the modern laboratory. A new hematology analyzer must undergo comparability testing with a currently used hematology analyzer. This study aimed to compare the performance of the Dymind DH-76 and Sysmex XN-1000 hematology analyzers. This study involved 96 EDTA blood samples from patients aged 18 to 85 years old at a hospital in Jakarta. A complete blood count was performed on each blood sample using two above-mentioned analyzers Dymind DH-76 and Sysmex XN-1000. The results from both instruments were compared by using the Pearson correlation test and the Passing-Bablok regression analysis to determine the agreement in performance between the two instruments. Between the Dymind DH-76 and Sysmex XN-1000, there was a high degree of agreement and correlation concerning the investigated parameters with r > 0.900 and p<0.001 for the parameters RBC, HGB, WBC, HCT, MCV, MCH, and neutrophil, monocyte, and eosinophil counts. The MCHC parameter had the values of r=0.797; p=0.0001, while the lymphocytes parameter had r=0.734 and p=0.0001. Only the basophils parameter showed a different result between the two aforementioned analyzers, with r=-0.179 and p=0.102. The majority of complete blood count parameters showed an excellent correlation and a high degree of agreement between the two instruments. The Dymind DH-76 hematology analyzer meets international standards (National Committee for Clinical Laboratory Standards/NCCLS) and can be used for hematological assay in the laboratory.
Performance Comparison of Dymind DH-76 and Sysmex Xn-1000 Automated Hematology Analyzers Pusparini Pusparini; Alvina Alvina
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY Vol. 28 No. 3 (2022)
Publisher : Indonesian Association of Clinical Pathologist and Medical laboratory

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24293/ijcpml.v28i3.1907

Abstract

An automatic hematology analyzer is an essential instrument for the modern laboratory. A new hematology analyzer must undergo comparability testing with a currently used hematology analyzer. This study aimed to compare the performance of the Dymind DH-76 and Sysmex XN-1000 hematology analyzers. This study involved 96 EDTA blood samples from patients aged 18 to 85 years old at a hospital in Jakarta. A complete blood count was performed on each blood sample using two above-mentioned analyzers Dymind DH-76 and Sysmex XN-1000. The results from both instruments were compared by using the Pearson correlation test and the Passing-Bablok regression analysis to determine the agreement in performance between the two instruments. Between the Dymind DH-76 and Sysmex XN-1000, there was a high degree of agreement and correlation concerning the investigated parameters with r > 0.900 and p<0.001 for the parameters RBC, HGB, WBC, HCT, MCV, MCH, and neutrophil, monocyte, and eosinophil counts. The MCHC parameter had the values of r=0.797; p=0.0001, while the lymphocytes parameter had r=0.734 and p=0.0001. Only the basophils parameter showed a different result between the two aforementioned analyzers, with r=-0.179 and p=0.102. The majority of complete blood count parameters showed an excellent correlation and a high degree of agreement between the two instruments. The Dymind DH-76 hematology analyzer meets international standards (National Committee for Clinical Laboratory Standards/NCCLS) and can be used for hematological assay in the laboratory.
Effect of Three and Six Months of Vitamin D Supplementation on Glycemic Control and Insulin Resistance in Type 2 Diabetes Mellitus: Randomized Placebo-controlled Trial Alvina Alvina; Suzanna Immanuel; Dante Saksono Harbuwono; Frans Dhyanagiri Suyatna; Alida Harahap; Joedo Prihartono; Pusparini Pusparini
The Indonesian Biomedical Journal Vol 15, No 3 (2023)
Publisher : The Prodia Education and Research Institute (PERI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18585/inabj.v15i3.2370

Abstract

BACKGROUND: 25(OH)D level is correlated with insulin secretion and tissue sensitivity to insulin. Administration of vitamin D supplements may reduce tissue resistance to insulin in type 2 diabetes mellitus (T2DM), but a number of studies found conflicting results. The present study was to measure the results of administration of vitamin D supplements for 3 and 6 months regarding HbA1c, fasting blood glucose (FBG), insulin and tissue resistance to insulin in T2DM cases.METHODS: A randomized double-blind placebo-controlled trial was conducted in T2DM patients with ≤3 years duration. Subjects were randomly divided into two groups: 47 subjects received daily 5000 IU vitamin D supplementation and 47 subjects received daily placebo as control. After supplementation for 3 and 6 months, homeostatic model assessment for tissue resistance to insulin (HOMA-IR), insulin, HbA1c, and FBG were examined.RESULTS: Supplementation of daily 5000 IU vitamin D for 3 months increased 25(OH)D level in the vitamin D group from 12.50±5.28 to 43.57±17.14 ng/mL, and after 6 months the 25(OH)D level was 38.38±17.64 ng/mL. Both groups showed significant differences after 3 and 6 months regarding HOMA-IR (p=0.033 and p=0.031), insulin (p=0.034 and p=0.013), but not FBG (p=0.296) and HbA1c (p=0.360). In both groups, HOMA-IR and insulin increased although the increase in the control group was greater than in the vitamin D group. The difference between the control and vitamin D groups was significant.CONCLUSION: Vitamin D supplementation for 3 and 6 months may lead to improvement HOMA-IR but not for FBG and HbA1c in the vitamin D group as compared with the control group in T2DM cases.KEYWORDS: vitamin D, T2DM, HbA1c, blood glucose, insulin, tissue resistance to insulin
Hubungan antara hipertensi dengan albuminuria pada usia 40-70 tahun Kamia Puspita Sardi; Pusparini Pusparini
Jurnal Biomedika dan Kesehatan Vol 2 No 1 (2019)
Publisher : Fakultas Kedokteran Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18051/JBiomedKes.2019.v2.3-9

Abstract

LATAR BELAKANGHipertensi merupakan penyakit kronis yang sering ditemukan seiring dengan peningkatan usia. Penyakit ini membutuhkan kontrol tekanan darah secara optimal dan merupakan faktor risiko terjadinya gagal ginjal tahap akhir atau end-stage renal disease (ESRD). Pada penderita hipertensi salah satu petanda adanya kebocoran pada ginjal adalah dengan dijumpainya albuminuria. Tujuan penelitian ini adalah untuk mengetahui hubungan antara hipertensi dengan albuminuria. METODEPenelitian ini merupakan penelitian dengan desain potong lintang mengikutsertakan 40 responden. Data diambil dari rekam medis dari bulan Desember 2014-Desember 2015 di salah satu rumah sakit swasta di Jakarta Pusat. Kriteria inklusi adalah pria dan wanita usia 40-70 tahun, menderita hipertensi, dan pada rekam medis terdapat data tekanan darah dan hasil albuminuria. Kriteria eksklusi adalah data rekam medis tidak lengkap, menderita diabetes melitus, gagal jantung dan menderita infeksi saluran kemih. Analisis data dilakukan dengan menggunakan uji Spearman dengan tingkat kemaknaan p<0.05. HASILUsia subjek yang paling dominan adalah usia 50-59 tahun (37.5%), dengan jenis kelamin sama banyak antara pria dan wanita masing-masing 50%. Subjek dengan derajat hipertensi terbanyak yaitu hipertensi derajat 2 (37.5%) dan nilai albuminuria yang dominan adalah negatif. Hasil uji Spearman menunjukkan terdapat korelasi yang bermakna antara hipertensi dengan albuminuria (r=0.428, p=0.006). KESIMPULANTerdapat korelasi yang bermakna antara hipertensi dengan albuminuria yang menunjukkan bahwa semakin tinggi tekanan darah pada pasien hipertensi, maka semakin besar kadar albuminuria.
Hubungan intensitas pemakaian gawai dengan neck pain pada usia 15-20 tahun Yuni Tri Yustianti; Pusparini Pusparini
Jurnal Biomedika dan Kesehatan Vol 2 No 2 (2019)
Publisher : Fakultas Kedokteran Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18051/JBiomedKes.2019.v2.71-76

Abstract

LATAR BELAKANG Dekade terakhir menunjukkan neck pain pada remaja semakin meningkat, bersamaan dengan meningkatnya penggunaan gawai (gadget). Seiring perkembangan zaman, gawai menjadi kebutuhan dan gaya hidup masyarakat luas. Pelajar menjadi pasar terbesar dalam penggunaan gawai sehubungan dengan kebutuhan belajar yang memerlukan akses Internet. Salah satu faktor penyebab neck pain pada pengguna gawai adalah intensitas penggunaan gawai yang mempengaruhi lamanya posisi fleksi pada otot leher. Tujuan penelitian ini adalah untuk mengetahui hubungan intensitas pemakaian gawai dengan neck pain pada usia 15-20 tahun. METODE Penelitian ini merupakan studi observasional dengan desain cross sectional yang mengikutsertakan 164 pelajar SMAN 28 Jakarta dan Fakultas Hukum Universitas Trisakti. Data dikumpulkan dengan cara pengisian kuesioner yang meliputi usia, jenis kelamin, intensitas pemakaian gawai dan keluhan neck pain. Penilaian neck pain menggunakan NRS (Numeric Rating Scale). Analisis data dilakukan dengan uji Chi-square dengan tingkat kemaknaan p<0.05. HASIL Subjek perempuan berjumlah 121 orang (73.8%). Paparan gawai dengan intensitas >56 jam/minggu dijumpai pada 109 subjek (66.5%). Keluhan neck pain dijumpai pada 138 subjek (84.1%). Uji Chi-square menunjukkan terdapat hubungan yang bermakna antara intensitas penggunaan gawai dengan neck pain pada usia 15-20 tahun dengan nilai p=0.004. KESIMPULAN Terdapat hubungan yang bermakna antara intensitas penggunaan gawai dengan neck pain pada usia 15-20 tahun.
Perbandingan disfungsi seksual antara perempuan pengguna kontrasepsi oral dan kontrasepsi suntik Nita Irawan Anugerah Pratama; Pusparini Pusparini
Jurnal Biomedika dan Kesehatan Vol 2 No 3 (2019)
Publisher : Fakultas Kedokteran Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18051/JBiomedKes.2019.v2.124-129

Abstract

LATAR BELAKANGDisfungsi seksual merupakan masalah dalam siklus respons seksual yang mengakibatkan individu gagal mendapatkan kepuasan dalam akivitas seksual. Disfungsi seksual meliputi berbagai gangguan dalam hubungan seksual, yang pada perempuan secara sederhana terbagi menjadi gangguan keinginan atau hasrat seksual, gairah, pelumasan, orgasme, kepuasan dan nyeri dalam hubungan seksual. Salah satu faktor penyebab terjadinya disfungsi seksual adalah efek samping dari penggunaan alat kontrasepsi hormonal. Penelitian ini bertujuan untuk mengetahui perbedaan disfungsi seksual pada pengguna kontrasepsi oral dan kontrasepsi suntik. METODEPenelitian ini menggunakan desain potong lintang. Sebanyak 132 perempuan yang terdiri dari 66 perempuan yang menggunakan kontrasepsi oral dan 66 yang menggunakan kontrasepsi hormonal berusia 15 – 49 tahun yang memenuhi kriteria inklusi dan eksklusi diikutsertakan dalam penelitian ini. Penelitian dilakukan pada bulan April sampai dengan Juni 2019 di Puskesmas Kembangan Jakarta Barat. Untuk mengetahui adanya disfungsi seksual digunakan kuesioner Female Sexual Function Index (FSFI). Analisa statistik menggunakan uji Chi-square dengan nilai p<0.05 berbeda bermakna. HASILRerata usia subjek penelitian pada pengguna kontrasepsi oral adalah 32.10 ± 6.2 tahun dan kontrasepsi suntik adalah 31.56 ± 6.4 tahun. Sebagian besar subjek mengalami disfungsi seksual sebanyak 73 orang (55.3%). Kejadian disfungsi seksual pada pengguna kontrasepsi suntik lebih banyak dibandingkan dengan kontrasepsi oral yaitu sejumlah 52 orang (78%) dengan nilai p=0.000. KESIMPULANDisfungsi seksual pada perempuan yang menggunakan kontrasepsi suntik lebih sering terjadi daripada pengguna kontrasepsi oral, sehingga pengguna kontrasepsi hormonal lebih baik menggunakan kontrasepsi oral dibandingkan kontrasepsi suntik untuk meminimalisasi kejadian disfungsi seksual.
Tes serologi dan polimerase chain reaction (PCR) untuk deteksi SARS-CoV-2/COVID-19 Pusparini Pusparini
Jurnal Biomedika dan Kesehatan Vol 3 No 2 (2020)
Publisher : Fakultas Kedokteran Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18051/JBiomedKes.2020.v3.46-48

Abstract

Penyebaran penyakit virus corona 2019 (COVID-19) di dunia meningkat sangat cepat, sehingga oleh World Health Organization (WHO) dinyatakan sebagai suatu pandemi global. Pada kondisi pandemi ini, lansia dan populasi yang rentan perlu mendapat perlindungan dari penyebaran COVID-19. Sebagian besar individu yang terinfeksi virus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) tidak menunjukkan gejala atau hanya bergejala ringan sampai sedang, dengan gejala mirip flu atau infeksi flu lainnya, sehingga bila kita kehilangan kemampuan untuk mengikuti jejak semua orang yang pernah terinfeksi SARS-CoV-2 maka proses identifikasi individu yang potensial terinfeksi akan menjadi sulit. Untuk dapat memproteksi populasi yang rentan maka diperlukan status dari seseorang yang pernah kontak dengan pasien COVID-19 secara cepat.(1)