Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : MEKTEK

EFEK UDARA DI DALAM SISTEM REFRIGERASI Patabang, Daud
MEKTEK Vol 7, No 2 (2005)
Publisher : MEKTEK

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (515.666 KB)

Abstract

The performance of refrigeration system are affected by  condenser, evaporator ,compressor and regulating  valve. Besides   cooling system itself   air in the system are also considered to the performance. The aim of this research to investigate the effect of air in the refrigeration system that  cause the performance of system. The result of this research indicates that coefficient of performance (COP)decrease falls to 37 % (from 8.4 to 5.28) due to the air in refrigerations system, on the contrary  there  is increasing about 40 % (from 25 kJ/kg to 35 kJ/kg)of energy in gernerating compressor
ANALISIS NILAI KALOR SECARA EKSPERIMENTAL DAN TEORITIK DARI BRIKET ARANG KULIT KEMIRI Patabang, Daud
MEKTEK Vol 11, No 3 (2009)
Publisher : MEKTEK

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (268.047 KB)

Abstract

The aim of this article is to investigate heating value of candlenut shell Char briquette by experimental andtheoretical means. The experimental performs the High Heating Value HHV by Bomb Calorimeter PARR12611, and investigation in the theoretical ones by using Dulong’s formula.The result shows that the heating value of HHV is 10697,4 Btu/lbm, and by Dulong’s formula is10549,Btu/lb. There is 1,16% deviation of the two means because in the Dulong’s does not includedissociation effect