M. Toni Prasetyo
Faculty Of Engineering, Muhammadiyah University Semarang, Indonesia

Published : 13 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 13 Documents
Search

PENGARUH IMPLEMENTASI MODEL PEMBELAJARAN IDEAL PROBLEM SOLVING BERBASIS MAPLE TERHADAP KEMAMPUAN PEMECAHAN MASALAH Purnomo, Eko Andy; Prasetyo, Muhammad Toni
PROSIDING SEMINAR NASIONAL & INTERNASIONAL 2017: PROSIDING IMPLEMENTASI PENELITIAN PADA PENGABDIAN MENUJU MASYARAKAT MANDIRI BERKEMAJUAN
Publisher : Universitas Muhammadiyah Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (197.411 KB)

Abstract

Metode numerik merupakan salah satu metode yang mempunyai peran sangat strategis dalam matematika. Masalah yang sulit atau bahkan tidak mungkin diselesaikan secara analitis dapat diselesaikan dengan metode numerik. Berdasarkan observasi awal peneliti disimpulkan bahwa 1) mahasiswa cenderung menghafal dan bukan memahami metode numerik, 2) pembelajaran masih bersifat konvensional, 3) mahasiswa belum mengetahui secara mendalam aplikasi metode numerik dalam kehidupan, 4) pembelajaran belum memanfaatkan aplikasi teknologi. Hal ini menyebabkan mahasiswa pasif dan motivasi belajar juga turun yang mengakibatkan kemampuan pemecahan masalah masih rendah. Solusi untuk mengatasi permasalahan pada matakuliah Metode Numerik adalah dengan penerapan model pembelajaran IDEAL Problem Solving berbasis Maple. Penelitian ini bertujuan untuk mengetahui pengaruh implementasi model pembelajaran IDEAL Problem Solving berbasis Maple pada matakuliah Metode Numerik. Hasil penelitian menunjukkan bahwa terdapat pengaruh keaktifan dan motivasi terhadap kemampuan pemecahan masalah yang signifikan. Berdasarkan hasil penelitian, dosen hendaknya dapat menerapkan model pembelajaran IDEAL problem solving berbasis maple untuk meningkatkan keaktifan, motivasi dan kemampuan pemecahan masalah. Kata Kunci: IDEAL problem solving, Maple, Metode Numerik
EFEKTIFITAS PEMAKAIAN REAKTOR SHUNT GITET UNGARAN DALAM MENGKOMPENSIR DAYA REAKTIF SUTET 500 KV UNGARAN – BANDUNG SELATAN M.Toni Prasetyo; Andika Akhmad
MEDIA ELEKTRIKA Vol 6, No 2 (2013): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (189.533 KB) | DOI: 10.26714/me.6.2.2013.%p

Abstract

Operasi sub jaringan tegangan ekstra tinggi Jawa Bali pada saluran panjang tanpa pembangkit yaitu Ungaran - Bandung Selatan dalam keadaan tanpa beban / beban rendah akan timbul arus pengisian relatif tinggi karena pengaruh adanya kapasitansi saluran ke tanah. Arus pangisian yang tinggi mengakibatkan terjadinya daya reaktif kapasitif (Mvar) yang besar. Daya reaktif yang dibangkitkan oleh SUTET 500 KV adalah kurang lebih 1 (satu) Mvar per kms, jadi jika jarak Ungaran - Bandung Selatan adalah 342,847 Kms maka daya reaktif yang dibangkitkan kurang lebih 343 Mvar. Akibatnya tegangan sisi terima akan lebih tinggi dari tegangan sisi kirim, melebihi batas toleransi yang diijinkan oleh PT PLN (Persero) yaitu > 5% diatas tegangan nominal 500 KV. Karena tegangan 500 KV lebih tinggi dari tegangan nominalnya maka direspon pula oleh tegangan kerja dibawahnya yaitu 150 KV dan 20 KV akan lebih tinggi juga yang pada akhirnya berpengaruh terhadap sistem kelistrikan Jawa Bali termasuk konsumen / beban. Untuk mengatasi adanya gejala kenaikan tegangan sisi terima lebih tinggi dari sisi kirim (terutama saluran panjang) perlu dipasang alat kompensasi berupa reaktor shunt pada kedua ujung, sisi terima maupun sisi kirim.
EVALUASI PERLINDUNGAN GARDU INDUK 150 KV PANDEAN LAMPER DI TRAFO III 60 MVA TERHADAP GANGGUAN SURJA PETIR Ihwan Ernanto Wibowo; Luqman Assaffat; M. Toni Prasetyo
MEDIA ELEKTRIKA Vol 5, No 2 (2012): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (914.719 KB) | DOI: 10.26714/me.5.2.2012.%p

Abstract

One of the main causes of damage to existing equipment in the substation was struck bylightning attack that cause the conductor wave and make over voltage and flames leap peak voltage exceeds BIL. The aim of this study was to calculate and analyze the level of protection, against power transformer arrester, the safe distance between arrester and transformer power to get a good protection against harmful lightning surges, comparing both arresters installed. To solve the problems of interference caused by lightning surge lightning arrester is installed as close as possible to put on the transformer clamps to protect electrical equipment. The results of calculations for a distance of 6 m, 4 MBA type 2 arrester capable of with standing the wavefront steepness of 500 kV / μs, while type exlim P 700 kV / μs. The greater the arrester capable of withstanding surge wavefront tilting the better the equipment in substations are protected. The evaluation shows that the distance between arrester and transformer installed in the 150 kV substation Pandean Lamper less than the maximum to protect electrical equipment, especially power transformers.Key words : lightning attack, arrester distance, level of protection.
ANALISIS KOMPARASI PEMILIHAN LAMPU PENERANGAN JALAN TOL Sri Pringatun; - Karnoto; M. Toni Prasetyo
MEDIA ELEKTRIKA Vol 4, No 1 (2011): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (804.839 KB) | DOI: 10.26714/me.4.1.2011.%p

Abstract

Street lighting is an integral part of the highway construction. The main purpose of highway lighting is to produce the speed, accuracy, and comfort of vision at night time, keep the quality of visibility, and makes it easier for passing vehicles. Highway lighting function other thanto enhance rider safety and comfort, especially in anticipation of situations traveling at night also for environmental safety or to prevent crime and to provide comfort and beauty of the surroundings. This research activity begins with the collection of data on the kind of - kind of street lighting, lighting as well as the formulation of data - other data you need, and then do the calculation and analysis of the data - the data obtained. The results that the lights SON - T 150 W at 19:43 lux illumination values and SON lamps - T 250 W value of 36.27 lux illumination, the totalpower of 19,050 W, PLN subscription fee of Rp. 25,575,000.00, electric bill per month USD. 6,069,330.00, the investment cost of Rp.196,567,800.00. By using the method of comparative analysis it can be concluded that the selection of lamps SON - T as highway lighting Semarang - Semarang Solo Ruas Phase I - Section I Bawen Tembalang - Gedawang is the best.Keywords: highway lighting lamps, SON - T, Comparison.
SIMULASI PELEPASAN BEBAN DENGAN RELAYFREQUENCY PADA SISTEM TENAGA LISTRIK CNOOC SES Ltd.NORTH BUSINESS UNIT MENGGUNAKAN SOFTWARE ETAP 7.5 Syarif Mahmud; M. Toni Prasetyo; Achmad Solichan
MEDIA ELEKTRIKA Vol 7, No 1 (2014): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (191.693 KB) | DOI: 10.26714/me.7.1.2014.%p

Abstract

Adanya gangguan pada sistem tenaga listrik dapat memicu ketidakstabilan frekuensi sistem. Tugas Akhir ini membahas tentang skema pelepasan beban menggunakan rele frekuensi pada sistem tenaga listrik CNOOC SES Ltd. North Business Unit yang mempunyai pembangkit listrik tenaga gas. Metode yang digunakan untuk simulasi transien analisis adalah perangkat lunak ETAP 7.5. Pelepasan beban dapat memulihkan frekuensi dengan cepat dan jumlah beban yang dilepaskan seminimal mungkin. Oleh sebab itu diperlukan seting waktu tunda rele, frekuensi kerja dan besar beban yang dilepaskan. Dari simulasi menggunakan rele frekuensi dapat mencegah penurunan frekuensi dan mengembalikan ke kondisi normal. Kata kunci:ETAP 7.5, Pelepasan Beban, Pembangkit Listrik Tenaga Gas, Rele Frekuensi
EFEKTIFITAS PEMANFAATAN PASIR PANTAI BERKALSIUM TINGGI SEBAGAI MATERIAL PENGISI BAHAN ISOLASI RESIN EPOKSI UNTUK ISOLATOR LISTRIK M. Toni Prasetyo
MEDIA ELEKTRIKA Vol 7, No 2 (2014): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (890.894 KB) | DOI: 10.26714/me.7.2.2014.%p

Abstract

Insulation materials that commonly used in air insulation, which, is operated at high voltage, are the porcelain, glass, and polymer materials. One of the insulating polymer materials that are used is epoxy resin because it has several advantages compared to that. However, this insulation material has a degradation of the surface due to environmental and cause insulation coated with dirt and chemicals in the long time. Material that was used in this research was epoxy resin polymer isolation using of comparison values (base material diglycidyl ether of bisphenol-A: hardener material metaphenylene diamine) were 1:1, with the increase of silane and high calcium coastal sand as filler by the value of 10%, 20%, 30%, 40%, and 50%. Research was done in laboratory according to standard IEC 587: 1984. In this study, the effect of variation in stoichiometry to the hydrophobic contact angle value, leakage current waveforms, and surface degradation caused by erosion and tracking processes and tracking time were analyzed. From the results of the research, it was obtained that the epoxy resin that was used in this research are categorized as hydrofobik and partially wetted. The increase concentration of silane dan high calcium coastal sand as filler caused the increase in contact angle which meant the increase in surface insulation resistance, so that leakage currents flew on the surface not easily and slow down the aging or the degradation decreasing on the surface of insulating material. Concentration value of filler that had the optimal performance of the tracking process and erosion was 40%. Keywords : Angle of contact, epoxy resin, hidropobik, leaky current, materials filler
EVALUASI METODE PENGUKURAN KONDISI ISOLATOR DALAM KEADAAN BERTEGANGAN JARINGAN 500 KV PENGHANTAR UNGARAN – MANDIRANCAN II TOWER 470 M. Toni Prasetyo; Novan Nur Hidayah
MEDIA ELEKTRIKA Vol 6, No 2 (2013): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (567.742 KB) | DOI: 10.26714/me.6.2.2013.%p

Abstract

Sistem transmisi menghantarkan energi listrik dalam tegangan yang sangat tinggi untuk jarak yang sangat jauh. Tegangan yang sangat tinggi dengan arus beban yang besar pula, menyebabkan semakin besar kemungkinan isolator yang menahan besarnya beban mekanis dan pejanan elektris terus menerus untuk mengalami kerusakan. Hal ini ditambah lagi dengan pengaruh alam dan lingkungan disekitarnya. Saat ini, pemeliharaan dan penggantian isolator dapat dilakukan dalam jaringan tanpa padam, tetapi sebelum memulai pelaksaannya, integritas mekanis dan elektris dari isolator perlu dikonfirmasikan terlebih dahulu. Melalui inspeksi secara visual dapat diketahui kerusakan fisik dari isolator tetapi tidak dengan integritasnya secara elektris. Untuk keperluan ini, telah banyak dikembangkan berbagai perangkat pengukuran yang mampu mengukur kondisi isolator dalam kondisi jaringan tanpa padam (energize). Beberapa diantaranya dapat digunakan hingga tegangan 765 kV. Ada dua macam perangkat pengukuran yang secara umum telah digunakan di Indonesia dengan dua macam metode kerja yang berbeda, antara lain Isolometer dan Positron Insulator Tester. Isolometer bekerja berdasarkan metode pengukuran beda potensial yang melintasi sebuah isolator, sedangkan Positron Insulator Tester bekerja berdasarkan pengukuran medan listrik pada sebuah isolator. Evaluasi disini untuk mengetahui perangkat pengukuran dan metode yang paling tepat dan paling efektif untuk digunakan di lapangan, terutama pada jaringan Ttransmisi Tegangan Tinggi 500 kV.
EFEKTIFITAS PENAMBAHAN FILLER PASIR BERKALSIUM PADA BAHAN ISOLASI RESIN EPOKSI DENGAN PENGUJIAN DEGRADASI PERMUKAAN M. Toni Prasetyo
MEDIA ELEKTRIKA Vol 6, No 1 (2013): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (334.555 KB) | DOI: 10.26714/me.6.1.2013.%p

Abstract

Bahan isolator udara yang dioperasikan pada tegangan tinggi adalah bahan polimer. Salah satunya adalah resin epoksi karena memiliki beberapa kelebihan. Namun memiliki kekurangan yaitu penuaan/degradasi pada permukaannya akibat pencemaran lingkungan. Bahan yang akan digunakan pada penelitian ini adalah komposit isolator polimer resin epoksi dengan nilai perbandingan (bahan dasar diglycidyl ether of bisphenol-A (DGEBA), bahan pengeras metaphenylenediamine (MPDA)) 1:1 dengan variasi peningkatan ukuran nilai pengisi (filler) pasir pantai dan silane 10%, 20%, 30%, 40%, dan 50%. Penelitian dilakukan menurut standar IEC 587 : 1984. Pengaruh variasi nilai konsentrasi terhadap nilai sudut kontak, bentuk gelombang arus bocor, dan degradasi permukaan yang diakibatkan proses penjejakan dan erosi beserta waktu penjejakannya dianalisis. Dari hasil penelitian, komposit epoksi resin yang digunakan pada penelitian ini dikategorikan bersifat hidrofobik dan basah sebagian. Penambahan konsentrasi pasir dan silane sebagai bahan pengisi, akan menambah besarnya sudut kontak, sehingga terjadi penambahan resistansi permukaa, akan memperkecil jalur karbon dan memperlambat peningkatan degradasi permukaan bahan isolasi, sehingga arus bocor tidak mudah mengalir. Nilai konsentrasi pengisi yang mempunyai kinerja optimal adalah 50%. Tetapi untuk konsentrasi yang paling tinggi yakni 50% secara fisik terlihat rapuh. Oleh karena itu untuk bahan isolator, yang mempunyai kinerja paling optimal terhadap proses penjejakan dan erosi adalah adalah 40%.
PENGUJIAN SUDUT KONTAK PADA BAHAN ISOLASI RESIN EPOKSI DENGAN PENGISI PASIR PANTAI YANG MENGANDUNG BANYAK KALSIUM M. Toni Prasetyo; Hamzah Berahim; T Haryono
MEDIA ELEKTRIKA Vol 5, No 1 (2012): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (6560.356 KB) | DOI: 10.26714/me.5.1.2012.%p

Abstract

Formation tracking power (electrical tracking) on the surface of an insulating material due to flashover continuously, especially when there are contaminants flotving on the surface of the insulating material. Due to electrical tracking the insulation material surface to be broken and easier flow of electric current. Insulating material must have good electrical characteristics leakage current is very small, the critical flashover voltage is very large and the surface is hydrophobic materials The material used in this study is an epoxy, resin insulating silicone rubber polymer with a fillerKukup beach sand containing a lot of caicium carbonate with stoichiomelric values (the ratio of materials and hardener or curing agent) is equal to 1, with values increasing sizefiller (filler) , 120x50 mm sample size. The study was conducted in the laboratory according to standard IEC 587: 1984. In this study, the effect of the variation of the filling of the contact angle and its influence on surface degradation caused by charging, were analyzed. The result showed that the epoxy resin used in this study whice are categorized partly wet (partially wetted) and approached hydrophobic. The more concentration of silicone rubber and sand as filler (filler.) will increase the hydrophobic nature of the contact angle shown is growing. lf the surface is hydrophobic, then the time required for the first discharge and breakdown on the surface of the old material.Keywords: epoxy resins, fillers, contact angle, hydrophobicity
ANALISIS PENYETELAN PROTEKSI ARUS LEBIH PENYULANG CIMALAKA DI GARDU INDUK 70 kV SUMEDANG Fajar Pranayuda; Achmad Solichan; M.Toni Prasetyo
MEDIA ELEKTRIKA Vol 5, No 2 (2012): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (658.866 KB) | DOI: 10.26714/me.5.2.2012.%p

Abstract

20 kV distribution of PLN is not free from distractions short circuit. Greatest short circuit fault current occurs at 20 kV bus bar. This led to widespread outages as a result of the major security operation. The aim of this study was to identify the final interruption of short circuit current, short circuit fault current to calculate and determine the values Over Current Relay (OCR) and Ground Fault Relay (GFR). This study purposed to calculate short circuit current. The subject of research is the disturbances that occurred in Cimalaka feeders. The data required for this study were obtained from the Area Manager Distribution of Bandung. The data is analyzed to determine the magnitude of short circuit current and Over Current Relay (OCR) and Ground Fault Relay (GFR) adjustment. The results show the short circuit fault current at 0% distance from feeder is 2428,391 A and short circuit current for 3 phase is 2103,049 A short circuit fault current and the second phase of 570,406 A short circuit fault current one phase to the ground. The difference in the relay settings data from the field with the calculation results showed that the differences are not too significant, so the ability of the relays is still good. Thus, the feeder protection relays Cimalaka at 70 kV substation Sumedang still good and doesn’t need to be reset. Keywords: Over Current Relay