STUDI INSPEKSI KELAYAKAN INSTALASI DAN INSTRUMEN TENAGA LISTRIK Nizar Rosyidi AS; Ilham Baihaqi
Sinusoida Vol 22 No 2 (2020): Jurnal Penelitian dan Pengkajian Elektro
Publisher : INSTITUT SAINS DAN TEKNOLOGI NASIONAL

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Motor induksi merupakan salah satu motor listrik yang banyak digunakan dalam dunia industri. Menurunnya kinerja motor induksi dapat disebabkan oleh beberapa factor seperti thermal stresses, mechanical stresses, dan environmental stresses. Oleh karena itu, perlu dilakukan perawatan guna menjaga kinerja motor tetap baik. Salah satu perbaikan yang ada pada motor induksi adalah rewinding motor. Rewinding adalah proses penggantian winding stator motor induksi secara total maupun parsial. Salah satu rewinding motor di PT. Mesindo Tekninesia adalah motor induksi tiga fasa 6,6 kV, 225 kW milik Pertamina Plaju, untuk mengidentifikasi jenis kerusakan dan menentukan langkah perbaikan serta melakukan pengecekan setelah perbaikan perlu dilakukan electrical test. Pengujian yang dilakukan untuk mengidentifikasi jenis kerusakan motor induksi adalah insulation resistance test dan DC resistance test, sementara pengujian insulation resistance test, DC resistance test dan running test. Dalam Studi ini akan dibahas tentang Pengujian Kelistrikan Motor Induksi 6,6 kV, 225 kW. PT. Mesindo Tekninesia, Jakarta Timur.
Pengaruh Susunan Konduktor pada Saluran Udara Tegangan Ekstra Tinggi (SUTET) Nizar Rosyidi AS; Edy Supriyadi; Sugianto Sugianto
SAINSTECH: JURNAL PENELITIAN DAN PENGKAJIAN SAINS DAN TEKNOLOGI Vol 33 No 4 (2023): Sainstech: Jurnal Penelitian dan Pengkajian Sains dan Teknologi
Publisher : Institut Sains dan Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37277/stch.v33i4.1747

Abstract

Abstract An effort to reduce or minimise electric field and medan magnit, a common transmission network to turn up for the conductor.But the tower transmission have some extent for environmental factors such as wind speed and construction cost to be more expensive.One of the influence of the strong electric fields magnit and the gap between its phase.How is the field of electricity and medan magnit the sutet 500 kv with this method of change the configuration of a conductor.This thesis is in the field of electricity and the horizontal magnit on the configuration, delta and vertical.The simulation done by the gap between fasanya on the configuration.From the calculation shows that if the distance between the phase changes made from 12 meters to 4.9 meters at the point of the review (0), then the magnetic flux density (B) it decreased from 6.83.10-6 be 1.58.10-6 tesla (horizontal configuration), the (delta configuration) decline of 5.9 .10-6 be 3.87.10-6 tesla tesla, and for (vertical configuration) penurunanannya of 1.12.10-5 be 6.8.10-6 tesla.While the results of the calculation of the electric field strength (E) by changing the distance between the phase from 12 meters to 4.9 meters at the point of the review (0), then there is a decrease in the electric field strength of 2.97 (kV / m) to 1.87 (kV / m) with (horizontal configuration), a decrease of 1.82 (kV / m) to 1.36 (kV / m) (vertical configuration).Likewise for delta configuration when the shortened distance between its phase, then the value of the electric field strength decreases from 0.949 (kV / m) to 0.769 (kV / m).Methods for calculating the linear regression on the delta configuration, vertical configuration, and horizontal slope (+) means that the greater the distance between the phase value of B and E increases.The resulting plot of magnetic flux density with distance between phases, the optimum value of the distance between the phase (δ) of 6.7 meters and the magnetic flux density (B) 8.03.10-6 (Tesla). While the electric field strength (E) 2.2 (kV / m). Method optimum value calculation results of electric field strength and magnetic flux density meet the standards set by WHO. Keywords: strong electric field, magnetic flux density, the distance between the phase and configuration
Analisa Penurunan Usia Transformator 1250 kVA Akibat Pembebanan pada Transformator di Rumah Sakit Swasta Nizar Rosyidi AS; Gilang andhika; Edy Supriyadi; Ariman Ariman
SAINSTECH: JURNAL PENELITIAN DAN PENGKAJIAN SAINS DAN TEKNOLOGI Vol 34 No 1 (2024): Sainstech: Jurnal Penelitian dan Pengkajian Sains dan Teknologi
Publisher : Institut Sains dan Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37277/stch.v34i1.2070

Abstract

Salah satu masalah yang sering terjadi pada transformator adalah kegagalan thermal dan panas berlebih yang mengakibatkan penyusutan usia pemakaian tranformator. Penelitian ini bertujuan untuk mengidentifikasi sejauh mana pembebanan mempengaruhi usia transformator. Penelitian ini dilakukan dengan pengambilan data lapangan atau data secara nyata yang terjadi di lapangan. Perhitungan perkiraan sisa usia transformator dihitung berdasarkan peramalan beban transformator lima tahun mendatang menggunakan analisa regresi linier. Pada IEC 354, hasil dari prediksi beban transformator 1250 kVA pada tahun 2024 memiliki sisa usia pemakaian kurang lebih 5 tahun, hal ini menandakan bahwa pemakaian transformator masih sesuai standard. Karena transformator beroperasi pada temperatur lingkungan rata – rata 30℃ maka sesuai hasil perhitungan dalam penelitian ini, suhu titik panas transformator telah melebihi 107,7℃ yang mencapai 137,67℃ pada pembebanan 127,83% dari rating daya transformator. Pada hasil perhitungan di tahun 2023 usia pemakaian transformator masih lebih dari 20 tahun. Dikarenakan nilai beban masih berada di bawah 80%. Pada tahun 2027 perkiraan usia transformator semakin berkurang hingga tersisa kurang dari 1 tahun dengan kondisi beban mencapai 127,83% dari rating daya transformator. Berdasarkan hasil prediksi yang telah diperoleh dari tranformator 1250 kVA yang mulai beroperasi pada tahun 2008, transformator tersebut hanya dapat bertahan hingga tahun 2024. Penyusutan usia dasar transformator tersebut disebabkan oleh pembebanan yang melebihi 80% kapasitas pemakaian yang terjadi pada tahun 2024. Kata kunci: Transformator, Tegangan AC, Perkiraan Usia, Regresi Linear, Prediksi Beban