Afif Budiyono
-

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

RANCANG BANGUN ALAT PENGUKUR DAN SISTEM JARINGAN DATA CO2 DI INDONESIA BERBASIS WEB Asif Awaludin; Ginaldi Ari Nugroho; Chunaeni Latief; Afif Budiyono
Jurnal Sains Dirgantara Vol 8, No 1 (2010)
Publisher : Lembaga Penerbangan dan Antariksa Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1324.813 KB) | DOI: 10.30536/j.jsd.2010.v8.a1534

Abstract

A web-based CO2 measurement device and a data network system in Indonesia which consist of the CO2 measurement device, the local data processor system, and the central data processor system has been built. The CO2 measurement device consist of the GMM220 CO2 sensor module from Vaisala and the data logger system. The data logger output consists of location, time, date, CO2 concentration, and input voltage, which packed all up in one data form with RGPGHG as the data header. The data logger system store the data into SD Card memory and ends it to the local data processor system. The CO2 Monitor Software in the local data processor system processes the data and display the graphical data which shows the maximum, minimum and average values of the data, and also sends the data to the central data processor system. The central data processor system displays data from several local data processor systems in the form of real time web-based graphical data and text, so the internet users can access and download its data. The development result device has been applicated in Kototabang, and the CO2 measurement device has been connected as well to the central data processor system in Bandung via the internet network to perform the web-based CO2 data network system in Indonesia. According to the data stored by the central data processor system for the periode of 1 - 26 March 2010, it shows that the CO2 concentration in Kototabang have an average of 403,5 ppm, with the maximum of 476,9 ppm and the minimum of 364,7 ppm. While the CO2 concentration in Bandung have an average of 397,2 ppm, with the maximum of 502,5 ppm and the minimum of 325,3 ppm. Key words: Data logger, CO2 sensor, Web-based interface
KARAKTERISTIK CO2 PERMUKAAN DI BANDUNG TAHUN 2008-2009 (PENGUKURAN TETAP DI WILAYAH PASTEUR) Chunaeni Latief,; Asif Awaludin; Afif Budiyono
Jurnal Sains Dirgantara Vol 8, No 1 (2010)
Publisher : Lembaga Penerbangan dan Antariksa Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1413.926 KB) | DOI: 10.30536/j.jsd.2010.v8.a1533

Abstract

A fixed instrument for CO2 measurement (LPN SATKLIM-1B) has been built and installed at LAPAN Bandung, started by using a direct recorder system on the computer then it is completed with data connection to the CO2 monitoring web server. The CO2 sensor used by NDIR technology has been corrected by the temperature and pressure compensation. The sensor was installed on 15 m above ground level, acquired and also recorded its data by monitoring the software developed by using the Microsoft Visual Basic 6.0. From the recording result of measurement data in Bandung from 2008 until 2009, with one minute interval data, it was obtained that the data characteristic compared to the measurement data from Global Atmospheric Watch (GAW) station in Kototabang (using spectroscopy technology) and Mauna Loa, all of them have the same pattern. From one year analysis (2008 – 2009) it was also obtained that by the increase of motor vehicle in Bndung for about 226,500 vehicle a year, 76% land building, and just 8.7% green open spaces, the CO2 has increased 1.5 ppm and the temperature from AWS data 2008-2009 (a year) data has increased 4.3ºC. In another side, the CO2 multiplication effect has occurred at 06.30-08.00 AM according to surface and vertical profile measuremens, due to stable atmosphere and calm wind. Key words: Surface fixed system, CO2 concentration, Convection