PENGUKURAN KARAKTERISTIK MUATAN MAKSIMUM PARTIAL DISCHARGE MATERIAL POLIMER EPOXY RESIN 20 KV PADA KELEMBABAN DAN KABUT GARAM RINGAN Satia Zaputra
ENSAINS JOURNAL Vol 3, No 2 (2020): ENSAINS Journal Mei 2020
Publisher : UNIVERSITAS KEBANGSAAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (548.897 KB) | DOI: 10.31848/ensains.v3i2.508

Abstract

Abstract: Epoxy resin polymer materials began to be widely used as electrical equipment insulation materials. One of them is used as the main insulation material in the manufacture of 20 kV outer-distribution current transformers. If the 20 kV distribution current transformer is placed outside, the polymer insulation performance follows the environmental conditions occupied. The main purpose of this study is to determine the performance response of partial discharges when the distribution current transformer is placed under environmental conditions of humidity and light salt fog. In various research literatures the maximum partial discharge is one of the causes of the failure of polymer material isolation in terms of the flash over mechanism associated with the performance of the surface leakage current of the insulator.Partial discharge measurement is performed by the fog chamber test method by providing a working voltage variation of 2-20 kV. The salt fog filtering method uses the IEC 507 standard, while the method of using the salt fog amount uses the IEC 815 standard ESDD impurity solution.The results of preliminary studies measuring the maximum partial discharge at 95% humidity and 4.6 ms / cm light salt mist produced a positive PD pulse of 26830 pC and a PD negative pulse of 65350 pC. Under conditions of high humidity RH 95%, a maximum load breakdown of the negative PD pulse occurs at a lower working voltage that is 8kV, Qmax = 12007 pC to Qmaks = 5231 pC at a working voltage of 10 kV. In the condition of a working voltage of 10 kV, the overload of the positive and negative PD maximum charge pulses also occurs. The data of measurement results of this study indicate the electrical and dielectric strength of epoxy resin material is unstable and fluctuating under conditions of high humidity, 95% RH wet.Keywords: epoxy resin, partial discharge, salt fogAbstrak:Material polimer resin epoksi mulai banyak digunakan sebagai bahan isolasi peralatan listrik. Salah satunya digunakan sebagai bahan isolasi utama dalam pembuatan trafo arus distribusi pasangan luar 20 kV. Trafo arus distribusi 20 kV ini jika ditaruh di outdoor (pasangan luar) maka kinerja isolasi polimer mengikuti kondisi dilingkungan yang ditempati.Tujuan utama penelitian ini adalah untuk mengetahui respon unjuk kerja partial discharge (peluahan sebagian) ketika Trafo arus distribusi ditaruh pada kondisi lingkungan kelembaban dan kabut garam ringan. Dalam berbagai literatur penelitian muatan maksimum partial discharge adalah salah satu penyebab kegagalan isolasi material polimer dari segi mekanisme flash over yang terkait dengan kinerja arus bocor permukaan isolator.Pengukuran peluahan sebagian dilakukan dengan metode fog chamber test (kamar uji kabut) dengan pemberian variasi tegangan kerja dari 2 – 20 kV. Metode pengotoran kabut garam menggunakan standar IEC 507, sedangkan metode penggunaan jumlah kabut garam menggunakan larutan pengotor ESDD standar IEC 815.Hasil studi awal pengukuran muatan maksimum peluahan sebagian pada kelembaban 95% dan kabut garam ringan 4.6 ms/cm menghasilkan pulsa positif PD sebesar 26830 pC dan pulsa negatif PD sebesar 65350 pC. Pada kondisi kelembaban tinggi RH 95% , terjadi breakdown muatan maksimum pulsa PD negatif pada tegangan kerja yang lebih rendah yaitu 8kV, Qmaks=12007 pC ke Qmaks=5231 pC pada tegangan kerja 10 kV. Pada kondisi tegangan kerja 10 kV ini pula juga terjadi overleap pulsa muatan maksimum PD positif dan negatif. Data informasi hasil pengukuran penelitian ini menunjukkan kekuatan elektris dan dieletrik material resin epoksi tidak stabil dan fluktuatif pada kondisi kelembaban tinggi , basah RH 95%.Kata kunci : resin epoksi, peluahan sebagian, kabut garam
KARAKTERISTIK ARUS BOCOR PELUAHAN SEBAGIAN MATERIAL RESIN EPOKSI TRAFO ARUS DISTRIBUSI PADA KONDISI POLUTAN KABUT GARAM Satia Zaputra
Jurnal TEDC Vol 11 No 2 (2017): Jurnal TEDC
Publisher : UPPM Politeknik TEDC Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (649.922 KB)

Abstract

Trafo Arus Distribusi Pasangan Luar banyak digunakan pada Saluran Udara Tegangan Menengah 20 kV. Bahan utama isolasinya adalah resin epoksi yang dicampur dengan semen putih (talk haichen). Dalam penggunaan di udara terbuka (pasangan luar) material resin epoksi mengalami penuaan isolasi akibat pengaruh berbagai kondisi lingkungan ( polutan dan kelembaban ). Dalam makalah ini disampaikan hasil pengujian pengukuran partial discharge (PD) dan arus bocor (leakage current) dari material resin epoksi tersebut . Hasil pengujian PD menunjukkan besar muatan maksimum sangat dipengaruhi oleh komposisi bahan pengisi resin epoksi tersebut. Kemampuan polutan dalam menyerap kandungan uap air (kelembaban) juga sangat mempengaruhi besar muatan maksimum PD yang terjadi. Pada kondisi basah (95% RH) diperoleh bahan pengisi semen putih terbaik adalah 75% prosentase beratnya untuk konduktivitas 4.6 mS dan 36 mS/cm, sedangkan untuk konduktivitas 24 mS/cm diperoleh komposisi bahan pengisi semen putih terbaik adalah 25% prosentase beratnya. Hasil pengujian arus bocor material resin epoksi menunjukkan besar kenaikan arus bocor sangat dipengaruhi oleh kondisi lingkungan (kelembaban dan polutan) . Pada kondisi basah (95% RH) fenomena pita kering (dry band) terjadi dalam fluktuasi kenaikkan arus bocor permukaan. Kondisi flash over sering terjadi pada tegangan uji 30 kV untuk konduktivitas 36 mS/cm.
KUALITAS PELAYANAN RESEPSIONIS DALAM MENANGANI TAMU CHECK IN DI HOTEL Apip, Nancy Durotun Nasihah; Zaputra, Satia
Jurnal Riset Manajemen Indonesia Vol 3 No 1 (2021): Jurnal Riset Manajemen Indonesia (JRMI)
Publisher : STIE Bangkinang Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Kualitas Pelayanan Resepsionis Dalam Menangani Tamu Check In Di Hotel. Penelitian ini bertujuan untuk mengetahui kualitas pelayanan resepsionois dalam menangani tamu check in di hotel Four Points by Sheraton Bandung. Metode yang digunakan dalam penelitian ini adalah deskriptif kualitatif. Sumber data berasal dari data primer dan data sekunder. Hasil penelitian didapatkan Kualitas Pelayanan yang dilihat dari pelaksanaan SOP dalam menangani tamu menyatakan bahwa delapan puluh sembilan persen Standar Operational Prosedur telah dijalankan dengan baik, dan sebelas persen tidak terlaksana, Sehingga dapat disimpulkan bahwa kualitas pelayanan receptionist dalam menangani tamu telah baik dengan persentase 90%. Kualitas Pelayanan yang dilihat dari hasil Guest Comment yang diberikan tamu menyatakan bahwa sebesar 50% dari tamu menyatakan pelayanan receptionist dengan baik, sedangkan 24% menyatakan sangat baik dan cukup baik,untuk sisanya sebesar 2% menyatakan kurang baik. Sehingga dapat disimpulkan bahwa kualitas pelayanan receptionist dikatagorikan baik dengan jumlah persentase yang dominan sebesar 50%. Sehingga disarankan Adanya jam padat atau terjadinya tamu check in secara bersamaan terutama di hari Sabtu sore, dimana tingkat occupancy rata-rata hampir seratus persen, maka sangat diperlukan tambahan personnel untuk bagian receptionist, sehingga tidak terjadi pelayanan receptionist yang tidak maksimal.
Effect of humidity and contaminants on dry band formation in Outdoor Distribution Current Transformer 20 kV Zaputra, Satia
Andalasian International Journal of Applied Science, Engineering and Technology Vol. 1 No. 02 (2021): November 2021
Publisher : LPPM Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/aijaset.v1i02.23

Abstract

This study reports the effect of humidity and pollutants on the formation of dry band phenomena on the insulation surface of an outdoor 20 kV distribution current transformer. From the results of measurements at high humidity 95% and high conductivity 36 mS/cm at a working voltage of 2-20kV test there is a change in the curve of increasing the value of the leakage current which is very volatile. Wet layer of impurity will cause a drastic decrease in surface resistance resulting in a large increase in leakage current. At a high conductivity of 36 mS/cm, the results of the measurement of surface resistance at low humidity of 55% worth 30.2 giga ohms decreased to 2.1 giga ohms at high humidity of 95%. While the value of the leakage current curve is very fluctuating from the value of 206 - 678 A at high conductivity with heavy pollutants. This information confirms the hypothesis that the boundary region of the two air-solid dielectrics of the epoxy resin causes surface discharge problems in dry band formation due to an increase in the non-uniform local electric field in the impurity layer adhering to the surface of the distribution current transformer. Keywords : leakage current, dry band, surface discharge, contaminants
Effect of humidity and contaminants on dry band formation in Outdoor Distribution Current Transformer 20 kV Zaputra, Satia
Andalasian International Journal of Applied Science, Engineering and Technology Vol. 1 No. 2 (2021): November 2021
Publisher : LPPM Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/aijaset.v1i02.23

Abstract

This study reports the effect of humidity and pollutants on the formation of dry band phenomena on the insulation surface of an outdoor 20 kV distribution current transformer. From the results of measurements at high humidity 95% and high conductivity 36 mS/cm at a working voltage of 2-20kV test there is a change in the curve of increasing the value of the leakage current which is very volatile. Wet layer of impurity will cause a drastic decrease in surface resistance resulting in a large increase in leakage current. At a high conductivity of 36 mS/cm, the results of the measurement of surface resistance at low humidity of 55% worth 30.2 giga ohms decreased to 2.1 giga ohms at high humidity of 95%. While the value of the leakage current curve is very fluctuating from the value of 206 - 678 A at high conductivity with heavy pollutants. This information confirms the hypothesis that the boundary region of the two air-solid dielectrics of the epoxy resin causes surface discharge problems in dry band formation due to an increase in the non-uniform local electric field in the impurity layer adhering to the surface of the distribution current transformer. Keywords : leakage current, dry band, surface discharge, contaminants