PENGARUH KECEPATAN PUTARAN BLOWER EVAPORATOR TERHADAP KINERJA AC MOBIL Wardika Wardika; Sunanto Sunanto; Ferry Sugara; Yusha Tri Mulya
Jurnal Teknologi Terapan Vol 4, No 2 (2018): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (644.391 KB) | DOI: 10.31884/jtt.v4i2.138

Abstract

The air distribution system in the room has the task of flowing cold or hot air into the room, a comfortable room condition is at a temperature of 24˚C. This study aims to determine the effect of the speed of the blower rotation on the performance of the car's AC. The cooling system in the vehicle, uses a blower to distribute cold air produced by the evaporator. Many choices of speed blowers to distribute cold air. In this study using variations in the speed value of blowers. Blower speed greatly affects the room / cabin temperature. Avoiding excessive energy consumption or inefficient energy consumption is indicated by a decrease in the COP from a cooling machine. After research obtained efficiency data for low blower rotation speed of 73.36%, medium rotation of 72.86%, and high rotation of 72.83%. But the fastest cooling of the cabin uses a high speed blower rotation. Keywords: Performance, Car AC, Speed Blower, Temperature
PERBANDINGAN PERFORMANSI MESIN REFRIGERASI KOMPRESI UAP CHEST FREEZER MENGGUNAKAN PIPA KAPILER dan ORIFICE ferry sugara
Jurnal Teknologi Terapan Vol 7, No 1 (2021): Jurnal Teknologi Terapan
Publisher : P3M Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jtt.v7i1.242

Abstract

Teknologi refigerasi saat ini memberikan pengaruh yang penting dalam peningkatan kualitas produk makanan. Chest dalam bahasa Inggris adalah peti, sedangkan freezer adalah pembeku. Chest freezer artinya adalah peti beku. Bentuknya adalah kotak kubus atau persegi panjang dan diletakkan di atas lantai. Akses pintu chest freezer berbentuk pintu buka atas, dan sangat efektif untuk menyimpan bahan makanan beku supaya kualitas makanan tetap baik setiap saat Tujuan dari penelitian ini adalah Mengetahui seberapa besar perbedaan performansi yang dihasilkan dari alat ekspansi berupa pipa kapiler dengan orifice dengan diameter yang berbeda dan mengetahui daya konsumsi listrik yang dipakai, sehingga mengetahui daya listrik per-hari. Metode yang dipakai dalam penelitian kali ini adalah melakukan pengujian pada sistem refrigerasi mesin pembuat es krim, dengan menguji performansinya dengan mengukur temperatur dan tekanan di setiap komponen utamanya saat sistem dalam keadaan steady. Hasil penelitian nilai COP aktual rata-rata diameter pipa kapiler 0,028 inchi adalah 2,16 sedangkan nilai COP aktual rata-rata orifice  0,031 inchi adalah 2,74. Dan nilai COP Aktual pipa kapiler diameter 0,028 inchi memiliki nilai lebih besar yaitu 2,16 sedangkan untuk orifice diameter 0,031 inchi memiliki nilai lebih kecil yaitu 1,88. Sedangkan untuk nilai efisiensi refrigrasi terbesar pada nilai rata-rata adalah pipa kapiler diameter 0,028 inchi sebesar 63,58 %. Sedangkan untuk orifice  diameter 0,031 inchi lebih kecil memiliki nilai efesiensi refrigrasi rata-rata 59,49% dan temperatur kabin pada pipa kapiler diameter 0,028 inchi nilai rata-rata dengan temperatur sebesar -9,82 0C. Sedangkan untuk orifice diameter 0,031 inchi lebih kecil memiliki nilai rata-rata lebih dingin yakni sebesar -9,09 0CKata Kunci: pipa kapiler,orifice dan COP.
Comparative Analysis of the Performance of Ice Cream Making Machines Using Variations in Capillary Pipe Diameters Ferry Sugara; Waluyo Djoko Yudisworo; Karsid Karsid
Mestro Vol 3 No 02 (2021): Edisi Desember
Publisher : Fakultas Teknik Universitas 17 Agustus 1945 Cirebon

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47685/mestro.v3i02.369

Abstract

Current refigeration technology has an important influence in improving the quality of food products. The purpose of this study is to find out how much the difference in performance generated from the expansion device in the form of two capillary pipes of different diameters and know the power consumption of electricity used, so that it knows the electric power per day. The method used in this study is to test the ice cream maker refrigeration system, by testing its performance by measuring the temperature and pressure in each main component when the system is steady. The results of the actual COP value of the average capillary pipe diameter of 0.028 inches are 2.16 while the actual COP value of the average capillary pipe diameter of 0.031 inches is 2.74. And the actual COP value of a 0.028 inch diameter capillary tube has a greater value of 2.16 while a capillary pipe with a diameter of 0.031 inches has a smaller value of 1.88. Whereas the biggest value of refractive efficiency at the average value is a capillary pipe with a diameter of 0.028 inches of 63.58%. While for capillary pipes with a diameter of 0.031 inches smaller the value of refraction efficiency averaged 59.49% and the cabin temperature in capillary pipes with a diameter of 0.028 inches, the average value was -9.82 0C. While for capillary pipes with a diameter of 0.031 inches smaller it has a cooler average value of -9.09 0C.
MESIN PENETAS TELUR BEBEK OTOMATIS BERBASIS ARDUINO UNO Ferry Sugara; Karsid; Bobi Khoerun
JURNAL REKAYASA ENERGI Vol. 2 No. 1 (2023): Jurnal Rekayasa Energi
Publisher : Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (356.647 KB) | DOI: 10.31884/jre.v2i1.31

Abstract

Perkembangan peternakan bebek di daerah Indramayu  pada umumnya masih menggunakan penetas telur manual,untuk itu perlu adanya alat penetas telur Bebek otomatis agar lebih effisien. Pembuatan alat ini bertujuan untuk, membangun perangkat keras dan perangkat lunak alat penetas telur otomatis berbasis mikrokontroler dan juga untuk mengetahui unjuk kerja sistem alat penetas telur otomatis berbasis mikrokontroler. Metode yang digunakan dalam membuat alat penetas telur dengan rak ayun otomatis berbasis mikrokontroler yang terdiri dari beberapa Tahap, yaitu identifikasi kebutuhan, analisis kebutuhan, perancangan sistem, perancangan perangkat lunak, pembuatan dan pengujian alat. Alat ini menggunakan beberapa komponen seperti mikrokontroler, Arduino R3 pada board arduino sebagai pengendali sistem, DHT22 untuk mendeteksi suhu dan kelembaban udara, LCD untuk media penampil hasil pengukuran suhu ruangan, serta motor stepper sebagai penggerak dan pengayun sehingga rak  dapat membalikan telur. Berdasarkan hasil pengujian yang telah dilakukan dapat diketahui bahwa perangkat keras telah berhasil dibuat menggunaan sistem mikrokontroler Arduino R3. Suhu dan kelembaban dalam box tetas 36 – 38 °C dan 50 – 60 % sesuai yang diharapkan. Motor stepper guna mengayunkan rak telur telah bekerja pada kondisi HIGH dan LOW. Uji kinerja Alat telah berhasil menetaskan telur tepat waktu selama 28 – 30 hari dengan tingkat keberhasilan sebesar 62 %.