AUDIT ENERGI DAN ANALISA PELUANG HEMAT ENERGI PADA BANGUNAN GEDUNG PT. X Derry Septian; Joko Prihartono; Purwo Subekti
Jurnal APTEK Vol. 5 No. 2 (2013): APLIKASI TEKNOLOGI
Publisher : Universitas Pasir Pengaraian

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (428.744 KB) | DOI: 10.30606/aptk.v5i2.83

Abstract

From the research that has been conducted on energy audits in buildings PT. X, to know the profile of energy use and energy savings opportunities, so it can be more efficient and save costs. From the initial energy audit have been implemented acquired Energy Consumption Intensity (IKE) to the total area is still under IKE standards for office buildings. For air-conditioned room is not air conditioned and acquired Energy Consumption Intensity (IKE) is low so as very efficient. By replacing energy-efficient appliances, then there is a chance of saving energy
PERHITUNGAN BEBAN PENDINGINAN INSTALASI TATA UDARA SISTEM FAN COIL CHILLED WATER DI GEDUNG SHOWROOM MOBIL JAKARTA Andri Setiawan; Joko Prihartono; Purwo Subekti
Jurnal APTEK Vol. 6 No. 1 (2014): APLIKASI TEKNOLOGI
Publisher : Universitas Pasir Pengaraian

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (278.254 KB) | DOI: 10.30606/aptk.v6i1.88

Abstract

Air conditioning for the building to be used as a car showroom in Jakarta is one thing that is needed to provide comfort and freshness to the workers so that the quality and quantity of work produced optimal . The cooling load can be influenced by various factors , among others : the weather , the condition of the building , the building volume , the shape of the building structure and the building materials used , the amount of ventilation air required , the function of the building , number of occupants , condition the outside air , indoor air conditions .
PERENCANAAN DAN KALIBRASIBATANGPELURUS BERDASARKANSTANDARJISB7514 Joko Prihartono; Purwo Subekti
Jurnal APTEK Vol. 6 No. 2 (2014): APLIKASI TEKNOLOGI
Publisher : Universitas Pasir Pengaraian

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (194.004 KB) | DOI: 10.30606/aptk.v6i2.100

Abstract

In the measurement process on a machine tool alignment required an alignment as the reference standard.In this case the rod straightener is a measurement tool that is commonly used in metrology laboratories. Inplanning and the alignment rod calibration followed standard JIS B7514, which is described in the standardspecification of the alignment rod which include dimensions, quality and tolerance limits. From the results ofthe calibration are performed on the alignment rod has a classification according to JIS B7514 standardclass (grade) B. Thus the alignment rod can only be used for testing machine tools with high level ofaccuracy that is not high (conventional).